Contact for Pricing
Overview
- 95 Series Aluminum Multi-Port Connector for 1/0 AWG conductors
- Force-fit connection eliminates need for soldering or crimping tools
- Includes concentric 1/0, compressed 1/0, compact 2/0, and solid 2/0 wire options
- Pre-cut and bagged for immediate installation and reduced labor time
- Compatible with standard compression tool die references (840,324,249,658,TX,76,11A)
Specifications
Application | Multi-port Connector |
Color | Black |
Conductor Range | 1/0 STR AWG , 1/0 COMPR AWG , 2/0 COMPT AWG , 2/0 SOL AWG |
Connection | Compression |
Insulation | yes |
Material | Aluminum Lug |
Mounting | Allen Head Mounting Bolt |
Special Features | Three Die Sets Install the Complete Range of Lugs from #8 to 350 kcmil. Lugs Prefilled with Oxide-Inhibiting Compound and Capped to Prevent Oxidation and Keep out Moisture. Insulating Flood-Seal Rocket |
Type | Flood Seal Multi Port Heat Shrink Fit Connector |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 0.2500 L |
Package Weight (Metric) | 0.1130 kg |

CFG 1/0 HS
Aluminum Flood-Seal Multi-Port Connectors - 95 Series Terminal Kits, Heat-Shrink kit, concentric 1/0, compressed 1/0, compact 2/0, solid 2/0, die reference 5/8,BG,687,243,TU,52,8A
TWB6359SD58
Aluminum Transformer Stud Connector Quick Disconnect - 350 Series, Ports 6, Cable Range #12 - 350 kcmil, Stud Size 5/8 inch, Street Light Option
TWB8359D58
Transformer Connectors-TWB 350 series, bare TWB bars, quick disconnect, cable range 12-350, height 2.6 inch, 66 mm, width 2.6 inch, 66 mm, length 4.1 inch, 105 mm, stud size 5/8 inch, ports 8
YDC 4
Copper Flood-Seal Street and Highway Lighting Compression Fuse and Disconnect Kits - YY-Type, non-fused, Main wire size # 4 CU, Tap wire size #14 - #6 CU. Contains Oxide Inhibitor. Consists of Twin Insulating Rocket and Twin Insulating Cap, Lugs, Fuse Clips, Wire, Screws, Washers, Nuts, Silicone Grease.
ABT 8500 DS-MGE
Aluminum Transformer Spade Connector, Double Set Screw, 8 Position, 6-500 MCM, 10 Long X 5.50 High X 1.50 Wide
ABW1964WPK/ABW6500SL
Aluminum Transformer Connector, cable size 6 to 500 mcm, Length 8-3/4 inch x 1-3/8 inch X 1-5/8 inch, Black PVC Boot 7-1/2 inch X 9-7/8 inch/Aluminum Quick Disconnect Transformer Connectors - ABW In-line bar, cable range 6-500, length 8-1/18 in, stud size 1, outlets 6, with Street Light Outlet Option wire size 14 to 2 AWG. Kit to consist of 3 Aluminum bars and 2 Black PVC boots.
ABW 40-66-1
Aluminum Quick Disconnect Transformer Connector, 6 Positions Double Row, 1 Inch Stud, 6.905 Long X 3.0 Hich X 1.50 Wide, 6-250 MCM
ABW4350 SLC SB 17BLK
Aluminum Quick Disconnect Transformer Connectors - ABW In-line bar, cable range 12-350, length 5-1/2 in, boot no. SB 17, stud size 5/8, outlets 4, with Street Light Outlet Option, Oxide Inhibitor, with Insulating Boots for Transformer Spade Connector, Black, - 5-15/16 inch long, 2-3/4 inch wide, 3-3/4 inch tall.How to Install the FLOOD-SEAL® FS-95 Connector Kit
This guide provides step-by-step instructions for installing the Thomas & Betts "FLOOD-SEAL"® FS-95 Force Fit Type Connector Kit, ensuring a proper and sealed connection for various cable sizes. Installation must be performed by trained installers.
Estimated time: 30m
Tools needed:
Cable cleaning supplies, Insulation penciling tool, Cutting tool (for sleeve), Crimping tool (for lugs), Wrench or socket set
Supplies needed:
FLOOD-SEAL® FS-95 Connector Kit, Electrical cable (matching conductor size), Electrical lug, Bus bar, Silicone grease
- Clean the Cable
Clean the cable thoroughly before installing the rocket sleeve to ensure optimal performance and sealing of the connection.
- Pencil the Cable Insulation
Pencil the cable insulation to prepare the cable end for the connector, creating a smooth, tapered profile for proper fitment.
- Select the Correct Cut Ring
Identify the correct conductor size for your cable and match it to the corresponding raised numbers on the cut rings of the rocket sleeve.
- Cut the Rocket Sleeve Tip
Carefully cut off the tip of the rocket sleeve at the selected ring. Ensure the cut leaves the required conductor range visible on the sleeve.
- Lubricate and Partially Install Rocket Sleeve
Lubricate both ends of the rocket sleeve and the prepared cable with silicone grease. Hold the cable at an angle to the sleeve's opening and twist the rocket sleeve while pushing it onto the cable, but do not yet slide it over the lug.
- Compress the Lug onto the Cable
Compress the electrical lug onto the prepared cable end using an appropriate crimping tool, ensuring a secure and reliable electrical and mechanical connection.
- Fully Position the Rocket Sleeve
Slide the rocket sleeve further over the compressed lug and onto the shoulder of the bus bar until the rocket sleeve firmly butts against the rubber of the connector bar, creating a complete seal.
- Bolt the Terminal to the Bus
Securely bolt the terminal (lug) to the bus bar, ensuring all connections are tight and meet specified torque requirements for a safe and effective installation.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.