ABB - Installation Products 776LR-N5380-S - 900 Amp, 35kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cold-Shrinkable Jacket Seal Included. Cable Insulation Diameter 1.515 inch to 1.780 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. Cold-Shrinkable Jacket Seal Included.

ABB Installation Products 776LR-N5380-S 900 Amp, 35kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and…

UPC: 075114126434


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

ABB 776LR-N5380-S is a 900 Amp, 35kV 600 Series Elbow termination kit for medium-voltage cable systems. It features a cold-shrinkable design with an integrated test point for non-invasive voltage verification without cable disconnection. The kit includes an insulated plug, cap, stud, bi-metal compression lug, and cable adapter for compressed stranded (700/750 kcmil) or compacted solid (900 kcmil) conductors with insulation diameters of 1.515–1.780 inches. The cold-shrinkable jacket seal provides a moisture-resistant, stress-relieved interface between cable and elbow, eliminating heat-shrink or tape applications. The bi-metal compression lug ensures compatibility with both copper and aluminum conductors, offering reliable electrical continuity and mechanical strength. Rated for 35kV class systems, this elbow is suitable for indoor and outdoor installations in switchgear, transformers, and cable terminations where space constraints or environmental conditions require a compact termination. The test point enables quick, safe voltage detection using standard hot-stick tools, reducing downtime during maintenance or fault isolation. The included components streamline installation, reducing labor costs and minimizing human error compared to traditional methods. This termination kit meets industry standards for medium-voltage cable accessories and is manufactured by ABB.
  • 900 Amp, 35kV class medium-voltage elbow termination
  • Integrated test point for safe voltage verification
  • Cold-shrinkable jacket seal for moisture-resistant installation
  • Bi-metal compression lug for copper/aluminum compatibility
  • Includes insulated plug, cap, stud, and cable adapter
  • Supports compressed stranded 700/750 kcmil or compacted solid 900 kcmil conductors
  • Insulation diameter range: 1.515 inch to 1.780 inch

Specifications

Amperage Rating
900 A
Application
35 kV, 900 Amps
Color
Black
Conductor Range
700 to 750 kcmil , 900 kcmil
Connection
Compression
Connection Type
Elbow with Test Point, Insulated Plug, Cap, Stud, Lug and Cable Adapter
Current Rating
900 A
Environmental Conditions
All Weather Conditions
Insulation
True
Material
Bi-Metal Compression Lug, Cold-Shrinkable Jacket Seal
Material
Housing - EPDM-Rubber
Series
600 Series
Size
Cable Insulation Diameter 1.515 inch to 1.780 inch
Special Features
Fully Shielded, Fully Submersible Molded Rubber Housing. 100 percent Peroxide-Cured Construction includes Insulation and Conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. S - Cold Shrinkable Jacket Seal
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector with Test Point
Voltage Rating
35 kV
Width
12.28 in
Width
311.912 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
900 Amp, 35kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included. Cable Insulation Diameter 1.725 inch to 1.935 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

776LR-P2380-SG3

900 Amp, 35kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included. Cable Insulation Diameter 1.725 inch to 1.935 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Copper Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

756LR-M2270-SG3

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Copper Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Copper Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

756LR-P2330-SG3

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Copper Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.900 inch to 2.120 inch. Conductor Size AWG or kcmil, Compacted Solid 1250.

756LR-Q0420

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.900 inch to 2.120 inch. Conductor Size AWG or kcmil, Compacted Solid 1250.
900 Amp, 35kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size Compressed Stranded 500 kcmil or Compacted Solid 600 kcmil

776LR-M2330

900 Amp, 35kV, 600 Series Elbow with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size Compressed Stranded 500 kcmil or Compacted Solid 600 kcmil
900 Amp, 35KV, DeadBreak Elbow, with Test Point, Cable Insulation Diameter 1.900 inch to 2.120 inch. Copper Compression Lug. Conductor Size Compressed Stranded 1000 kcmil. Cold-Shrinkable Jacket Seal Included.

776LR-Q2410-S

900 Amp, 35KV, DeadBreak Elbow, with Test Point, Cable Insulation Diameter 1.900 inch to 2.120 inch. Copper Compression Lug. Conductor Size Compressed Stranded 1000 kcmil. Cold-Shrinkable Jacket Seal Included.
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. Cold-Shrinkable Jacket Seal Included.

756LR-N0380-S

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. Cold-Shrinkable Jacket Seal Included.
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Copper Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

756LR-P2380

35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Copper Compression Lug. Cable Insulation Diameter 1.725 inch to 1.935 inch. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

Frequently Asked Questions

What is the primary application of the 776LR?

The 776LR provides fully shielded, dead-front submersible cable connections to high-voltage apparatus.

What is the maximum phase-to-ground operating voltage?

For the 35kV voltage class, the maximum phase-to-ground operating voltage is 21.1kV.

How is the 776LR connected or disconnected?

It can be easily connected or disconnected using standard hand tools and equipment, but only in a de-energized state.

Is the 776LR housing submersible?

Yes, the 776LR features a fully shielded, fully submersible molded rubber housing.

What is the momentary current rating?

The momentary current rating is 25kA Symmetrical for 10 cycles.

What is the continuous current rating?

The continuous current rating for the 776LR is 900 Amps.

What is the BIL impulse withstand rating?

The BIL impulse withstand rating is 150kV (1.2 x 50 microsecond wave).

What industry standard does the 776LR meet?

The 776LR meets ANSI/IEEE Standard 386, Latest Revision.

What other Elastimold products are compatible with 776BLR?

The 776BLR can be mated with Elastimold products like 775CP, 775BIP, 775ETP, 775SOP, 775S1, 775J2, 775J3, and 775J4.

What insulation diameters does the 776LR support?

The 776LR supports insulation diameters from 0.760 inches to 2.120 inches.

How to Install 755/775LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of 755LR and 775LR Deadbreak Elbow Connectors, designed for 35kV class systems to provide fully shielded, fully submersible deadfront cable connections.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Cable preparation tools, Wire brush (for aluminum conductors), Crimping tool, Torque wrench, Hotstick, Suitable voltage sensing device

Supplies needed:

755LR or 775LR Deadbreak Elbow Connector kit (includes Elbow, Cable Adapter, Compression Lug, Insulating Plug, Lubricant, Stud Prepack), High voltage cable, Mating apparatus bushing or connector, Grounding device or suitable grounding wire (min. No. 14 AWG Copper), Suitable connector for grounding wire, Silicone lubricant (for voltage test cap), Vinyl tape (if applicable for cable type), Tape retainer (if applicable for cable type)

  1. De-energize Apparatus and Inspect Components

    DANGER: Ensure all apparatus in the work area are de-energized before beginning installation. Do not touch or move energized products. Inspect the contents of the connector package for completeness and damage. Verify all components (elbow, cable adapter, compression lug, etc.) are present and undamaged. Check all components for proper fit and compatibility with the cable and mating products.

  2. Prepare the Cable

    Position the cable in its final assembled location, ensuring enough slack for elbow removal. For concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4” (45mm) from the centerline of the mating product. Clean the outer jacket of the cable for a distance of 24” (610mm). Prepare the cable according to its type (e.g., non-jacketed, jacketed, unishield, lead sheath) by removing the outer jacket, semi-con shield, and insulation to the specified dimensions (e.g., 10-3/8" (264mm) for insulation, 11-3/8" (289mm) for semi-con shield, 13-5/8" (340mm) for tape marker). Refer to specific instructions for grounding devices or shield adapters if applicable. Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4” (6mm) back. Thoroughly clean and lubricate the cable insulation, working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker. Carefully remove the protruding cable insulation, cutting it even with the end of the cable adapter. WARNING: Do not cut or nick the cable adapter or the conductor. Verify the exposed conductor length is between 4-3/8” to 4-3/4” (111mm-121mm); if not, redo the assembly.

  3. Install and Crimp the Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor immediately before fully inserting it into the compression lug. Measure the "Check Dimension" before crimping; it must be less than 7” (178mm). If not, redo the assembly. Crimp the compression lug following the instructions provided with the lug, ensuring the first crimp is located on the end closest to the cable adapter. Wipe all excess inhibitor from the compression lug and cable adapter surface after crimping. Verify the distance from the end of the compression lug to the cable adapter after crimping is between 6-7/8” to 7-5/8” (175mm-194mm). If not, redo the assembly.

  4. Install the Elbow Connector

    Lubricate the cable adapter and the inside of the elbow cable entrance with the supplied lubricant. Install the elbow onto the cable adapter, pushing until it cannot advance further. Ensure the cable adapter remains flush with the tape marker; reposition if necessary. Remove the tape marker.

  5. Connect the Elbow to Mating Products

    DANGER: DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. DO NOT ENERGIZE WHILE DISCONNECTED. Remove any protective caps from the elbow and the primary mating part. If the mating part is not equipped with a stud, hand tighten the threaded stud (supplied with the elbow) into it. Clean and lubricate both the elbow and the primary mating part with the supplied lubricant, keeping surfaces clean. Push the elbow onto the primary mating part, carefully aligning the hole in the compression lug with the stud on the mating part. Clean and lubricate the mating part for the opposite end of the elbow. Insert this secondary mating part into the elbow, engage the threads, and hand tighten. Torque the mating part according to its specific instructions. If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap, then place it on the elbow and push down hard until it snaps into place.

  6. Ground the Cable Shield

    Insert one end of a grounding wire (with ampacity at least equivalent to No. 14 AWG Copper) through the grounding eye and twist to form a small loop. WARNING: Do not damage the grounding eye. Connect this wire to ground using a suitable connector. Ensure the cable shield is properly grounded, either through a dedicated grounding device or an alternate approved method. It is recommended to waterproof the cable jacket at this point to prevent moisture ingress.

  7. Perform Voltage Test (Optional, but Recommended)

    CAUTION: For 600amp L-Kits, ensure each component is tightened to the specified torque per plug connector instructions. WARNING: The voltage test point is a capacitance device and is NOT directly connected to the conductor. Do not use conventional voltage measuring equipment. Follow the manufacturer’s directions for the specific meter used. Test with a suitable sensing device designed for capacitive test points. Contamination, moisture, dirt, or using the wrong equipment can lead to a false "no voltage" indication on an energized elbow. Always treat the elbow as energized until the "no voltage" test point indication is confirmed by other means to prevent serious or fatal injury. Remove the test point cap using a hotstick, peeling it off at an angle rather than pulling directly. Use a suitable sensing device to determine if the cable is energized. After the voltage detection, clean and lubricate the inside surface of the cap with silicone lubricant and replace it firmly on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.