Authorized ABB Distributor (Installation Products)
ABB - Installation Products 69TCJS1Q2405NLNNB - 69kV, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size Q - Bore Diameter 1.750 inch, Insulation Range 1.995-2.300 inch, Connector Type - Copper, Conductor Code 405, Heatsink Size and Bore not Required, Type Shield L - Lead and Neutral Wires, Metallic Screen Continuity Kit Not Required, Armour Kit Not Required, Outer Jacket Restoration Kit B - Heat Shrink Standard package.

ABB Installation Products 69TCJS1Q2405NLNNB 69kV, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing…

UPC: 783786428960


Documents & Media
Specification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 69kV Transmission Cable Joint, SKU 69TCJS1Q2405NLNNB, is specifically designed for high-voltage power transmission infrastructure. This joint features a Shieldbreak housing type and Housing Style 1, accommodating a bore diameter of 1.750 inches. Its insulation range is precisely engineered for cables with insulation diameters between 1.995 and 2.300 inches, ensuring a secure and reliable connection. The connector type is copper, and it is rated for Conductor Code 405. This model includes Type Shield L for metallic screen continuity, specifically addressing lead and neutral wires. Heatsink size and bore are not required for this configuration. An Armour Kit is not needed, and the package includes Outer Jacket Restoration Kit B, a standard heat shrink solution for restoring the cable's outer jacket integrity. Manufactured in the US, this ABB product provides a dependable solution for joining shielded transmission cables in demanding electrical environments where system reliability is paramount. Its UNSPSC code is 39121452.
  • 69kV rated for high-voltage transmission applications
  • Shieldbreak housing type and Housing Style 1
  • 1.750 inch bore diameter
  • Accommodates insulation range of 1.995-2.300 inches
  • Includes Type Shield L for metallic screen continuity (Lead and Neutral Wires)

Specifications

Application
For use on Solid Dielectric Cables - providing permanent, fully-shielded, fully submersible cable joints for direct burial or vault applications
Color
Black
Connection
Compression
Connection Type
Copper Connector
Connection Type
Shieldbreak
Insulation
Yes
Material
Copper
Material
EPDM Rubber
Number Of Conductors
2
Size
Housing Size Q - Bore Diameter 1.750 inch, Insulation Range 1.995-2.300 inch
Size
Bore Diameter 1.750 inch, Insulation Range 1.995-2.300 inch
Special Features
Each Cable Joint is produced exactly to design, producing a quality not possible with field molding equipment or tape. Electrically tested in the factory to ensure consistent quality. Molding is done in the factory, reducing on-site time - no penciling of cable installation required. Easy to learn installation procedure. Field molds, wrapping machines or pre-stretch not required, and a low-cost assembly tool is available. Extended shelf life enables instant availability of spares. Designed with optimized pre-molded stress control and heat transfer capabilities
Standard
ANSI C119.4, Shield Test IEEE 592
Temperature Rating, Maximum
194 F
Temperature Rating, Maximum
90 C
Temperature Rating, Minimum
194 F
Temperature Rating, Minimum
90 C
Type
Transmission Cable Joint - Shieldbreak
Voltage Rating
69 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
64.2000 L
Package Weight (Metric)
29.1210 kg
69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Size N Bore Diameter at Jacket/Insulation Transition 1.390. Connector Type - Copper, Connector Code 30P - Conductor Diameter Range - .636-.686 inch (16.15-17.42mm), Heatsink Size/Bore - E - .921 inch Diameter. Type Shield - B - Copper 1/3 Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - A - Jacket Tape 5 Rolls

69TCJN1N230PEBNNA

69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Size N Bore Diameter at Jacket/Insulation Transition 1.390. Connector Type - Copper, Connector Code 30P - Conductor Diameter Range - .636-.686 inch (16.15-17.42mm), Heatsink Size/Bore - E - .921 inch Diameter. Type Shield - B - Copper 1/3 Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - A - Jacket Tape 5 Rolls
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Copper, Connector Code 36P - Conductor Diameter Range - .901-.935 inch (22.88-23.75mm), Heatsink Bore - T - 1.859 inch Diameter. Type Shield - C - Copper Full Neutral Wire, Metallic Screen Continuity Kit - B - 4/0 Bonding Cable 6 foot quantity 2 with Split Bolts quantity 4, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink

69TCJS1Q236PTCBNB

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Copper, Connector Code 36P - Conductor Diameter Range - .901-.935 inch (22.88-23.75mm), Heatsink Bore - T - 1.859 inch Diameter. Type Shield - C - Copper Full Neutral Wire, Metallic Screen Continuity Kit - B - 4/0 Bonding Cable 6 foot quantity 2 with Split Bolts quantity 4, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink
69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size Q. Copper Connector. 33P. P U C B N B

69TCJS1Q233P36PUCBNB

69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size Q. Copper Connector. 33P. P U C B N B
69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size Q. 2 4 2 5 N L N N B

69TCJS1Q2425NLNNB

69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size Q. 2 4 2 5 N L N N B
69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size Q. Copper Connector. 365 T C B N B

69TCJS1Q2365TCBNB

69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size Q. Copper Connector. 365 T C B N B
69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size Q. Copper Connector. 335 R C B N B

69TCJS1Q2335RCBNB

69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size Q. Copper Connector. 335 R C B N B
69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size Q. Copper Connector. 335365 U C B N B

69TCJS1Q2335365UCBNB

69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size Q. Copper Connector. 335365 U C B N B
69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size P. B 3 6 5 N C B N B

69TCJS1PB365NCBNB

69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size P. B 3 6 5 N C B N B

Frequently Asked Questions

What is the voltage rating for this ABB cable joint?

This ABB cable joint is rated for 69kV, making it suitable for high-voltage transmission applications.

What is the bore diameter of this cable joint?

The bore diameter for this ABB cable joint is 1.750 inches.

What is the insulation range supported by this joint?

This ABB cable joint supports an insulation range of 1.995 to 2.300 inches.

What type of connector is used in this cable joint?

The connector type for this ABB cable joint is copper.

Does this cable joint require an armour kit?

No, an armour kit is not required for this specific ABB cable joint configuration.

What is included for outer jacket restoration?

The joint includes Outer Jacket Restoration Kit B, which is a heat shrink standard package.

What is the purpose of Type Shield L in this joint?

Type Shield L is for metallic screen continuity, specifically for lead and neutral wires.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.