ABB - Installation Products 69TCJS1Q236PTCBNB - 69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Copper, Connector Code 36P - Conductor Diameter Range - .901-.935 inch (22.88-23.75mm), Heatsink Bore - T - 1.859 inch Diameter. Type Shield - C - Copper Full Neutral Wire, Metallic Screen Continuity Kit - B - 4/0 Bonding Cable 6 foot quantity 2 with Split Bolts quantity 4, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink
ABB - Installation Products

69TCJS1Q236PTCBNB

UPC: 783786395835


Documents & Media
Specification SheetManufacturer Product Website

Contact for Pricing

Overview

The ABB 69kV Transmission Cable Joint (SKU: 69TCJS1Q236PTCBNB) is a shieldbreak housing type joint designed for high-voltage transmission cable systems. This joint features a copper connector (Code 36P) compatible with conductor diameters from 0.901 to 0.935 inches (22.88–23.75 mm). The housing includes a 1.750-inch bore diameter at the jacket/insulation transition and a 1.859-inch diameter heatsink bore (Type T). The metallic screen continuity kit includes two 4/0 bonding cables (6-foot length) with four split bolts for secure grounding. The outer jacket restoration kit uses heat-shrink technology for reliable environmental sealing. This joint is engineered for 69kV transmission applications where shield continuity and conductor integrity are critical. The shield type is copper full neutral wire (Type C), ensuring consistent electrical performance. The armor kit is not required for this configuration, simplifying installation. This product is part of ABB’s Installation Products catalog, a trusted manufacturer in high-voltage cable accessories.
  • 69kV rated transmission cable joint for high-voltage systems
  • Shieldbreak housing type with 1.750in bore diameter at jacket/insulation transition
  • Copper connector (Code 36P) compatible with 0.901–0.935in (22.88–23.75mm) conductors
  • Metallic screen continuity kit includes 2x 4/0 bonding cables (6ft) with 4 split bolts
  • Outer jacket restoration kit with heat-shrink technology for environmental sealing

Specifications

Application
For use on Solid Dielectric Cables - providing permanent, fully-shielded, fully submersible cable joints for direct burial or vault applications
Color
Black
Conductor Range
.901 to .935 in
Connection
Compression
Insulation
Yes
Material
EPDM Rubber
Number Of Conductors
2
Special Features
Each Cable Joint is produced exactly to design, producing a quality not possible with field molding equipment or tape. Electrically tested in the factory to ensure consistent quality. Molding is done in the factory, reducing on-site time - no penciling of cable installation required. Easy to learn installation procedure. Field molds, wrapping machines or pre-stretch not required, and a low-cost assembly tool is available. Extended shelf life enables instant availability of spares. Designed with optimized pre-molded stress control and heat transfer capabilities
Standard
ANSI C119.4, Shield Test IEEE 592
Temperature Rating, Maximum
194 F
Temperature Rating, Maximum
90 C
Temperature Rating, Minimum
194 F
Temperature Rating, Minimum
90 C
Type
Transmission Cable Joint - Shieldbreak
Voltage Rating
69 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
25.2500 L
Package Weight (Metric)
11.4530 kg
69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Aluminum, Connector Code 36P - Conductor Diameter Range - .901-.935 inch (22.88-23.75mm), Heatsink Size/Bore - N - 1.500 inch Diameter. Type Shield - D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - HeatShrink

69TCJN1Q136PNDNNB

69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Aluminum, Connector Code 36P - Conductor Diameter Range - .901-.935 inch (22.88-23.75mm), Heatsink Size/Bore - N - 1.500 inch Diameter. Type Shield - D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - HeatShrink
69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size Q. Copper Connector. 33P. P U C B N B

69TCJS1Q233P36PUCBNB

69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size Q. Copper Connector. 33P. P U C B N B
69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size Q. 2 4 2 5 N L N N B

69TCJS1Q2425NLNNB

69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size Q. 2 4 2 5 N L N N B
69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size Q. Copper Connector. 365 T C B N B

69TCJS1Q2365TCBNB

69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size Q. Copper Connector. 365 T C B N B
69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size Q. Copper Connector. 335 R C B N B

69TCJS1Q2335RCBNB

69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size Q. Copper Connector. 335 R C B N B
69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size Q. Copper Connector. 335365 U C B N B

69TCJS1Q2335365UCBNB

69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size Q. Copper Connector. 335365 U C B N B
69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size P. B 3 6 5 N C B N B

69TCJS1PB365NCBNB

69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size P. B 3 6 5 N C B N B
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Aluminum, Connector Code 42P - Conductor Diameter Range - 1.146-1.220 inch (29.11-30.99mm), Heatsink Bore - N - 1.500 inch Diameter. Type Shield - E - Lead, Metallic Screen Continuity Kit - E - 4/0 Bonding Cable 6 foot quantity 4 with Split Bolts quantity 8, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink

69TCJS1Q142PNEENB

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Aluminum, Connector Code 42P - Conductor Diameter Range - 1.146-1.220 inch (29.11-30.99mm), Heatsink Bore - N - 1.500 inch Diameter. Type Shield - E - Lead, Metallic Screen Continuity Kit - E - 4/0 Bonding Cable 6 foot quantity 4 with Split Bolts quantity 8, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink

Frequently Asked Questions

What are the key benefits of TCJ cable joints?

TCJ cable joints are factory molded and tested for consistent quality and reliability. They offer an easy-to-learn installation procedure, reducing on-site time and eliminating field molding or tape.

What is the maximum system voltage for 138 kV class joints?

The maximum system voltage for 138 kV class TCJ joints is 145 kV.

What standards do TCJ cable joints meet?

TCJ transmission cable joints meet type tests per IEC 60840/IEEE 404.

What is the minimum corona extinction voltage?

The minimum corona extinction voltage is 60 kV for 69 kV systems and 120 kV for 138 kV systems, both at 3 pC sensitivity.

What is the DC withstand voltage for 69 kV joints?

The DC withstand voltage for 69 kV class joints is 240 kV for 15 minutes.

What are the BIL ratings for TCJ cable joints?

For 69 kV systems, the BIL is 350 kV. For 138 kV systems, the BIL is 650 kV.

What is the maximum continuous conductor temperature?

The maximum continuous conductor temperature for TCJ transmission cable joints is 90 °C.

What is the maximum system voltage for 69 kV class joints?

The maximum system voltage for 69 kV class TCJ joints is 72.5 kV.

What are the typical applications for TCJ cable joints?

TCJ cable joints are suitable for direct-burial or vault applications, providing permanent, fully shielded, and fully submersible cable joints.

What insulation diameter range do TCJ joints support?

For Style 1 (through 69 kV), insulation diameters range from 1.43 inches to 2.58 inches. For Style 4 (through 138 kV), the range is 2.25 inches to 3.62 inches.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.