ABB - Installation Products 69TCJS1Q2425NLNNB - 69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size Q. 2 4 2 5 N L N N B
ABB - Installation Products

69TCJS1Q2425NLNNB

UPC: 783786423781


Documents & Media
Specification SheetManufacturer Product Website

Contact for Pricing

Overview

This ABB 69 kV TCJ Transmission Cable Joint, SKU 69TCJS1Q2425NLNNB, is designed for shieldbreak applications within high-voltage power transmission systems. The housing type is specifically shieldbreak, and the housing style is designated as Style 1. The housing size is Q, indicating a specific dimensional profile for compatibility with particular cable sizes and configurations. This joint is engineered to provide reliable electrical insulation and mechanical protection for transmission-grade cables operating at 69 kV. Its construction facilitates secure and dependable connections in demanding electrical infrastructure. The UNSPSC code 39121452 categorizes this product under electrical connectors and accessories. ABB's Installation Products division is the manufacturer, known for its comprehensive range of electrical components. This TCJ joint is a critical element for maintaining the integrity and operational continuity of power grids. Its specific design addresses the challenges of terminating and joining high-voltage transmission cables, ensuring safe and efficient power transfer. The precise sizing and shieldbreak functionality are key features for its intended use in substations and transmission line infrastructure.
  • 69 kV rated transmission cable joint
  • Shieldbreak housing type for enhanced protection
  • Housing Style 1 and Size Q for specific applications
  • Manufactured by ABB - Installation Products
  • Designed for high-voltage power transmission infrastructure

Specifications

Application
For use on Solid Dielectric Cables - providing permanent, fully-shielded, fully submersible cable joints for direct burial or vault applications
Color
Black
Connection
Compression
Insulation
Yes
Material
EPDM Rubber
Number Of Conductors
2
Size
Q
Special Features
Each Cable Joint is produced exactly to design, producing a quality not possible with field molding equipment or tape. Electrically tested in the factory to ensure consistent quality. Molding is done in the factory, reducing on-site time - no penciling of cable installation required. Easy to learn installation procedure. Field molds, wrapping machines or pre-stretch not required, and a low-cost assembly tool is available. Extended shelf life enables instant availability of spares. Designed with optimized pre-molded stress control and heat transfer capabilities
Standard
ANSI C119.4, Shield Test IEEE 592
Temperature Rating, Maximum
194 F
Temperature Rating, Maximum
90 C
Temperature Rating, Minimum
194 F
Temperature Rating, Minimum
90 C
Type
Transmission Cable Joint - Shieldbreak
Voltage Rating
69 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
64.2000 L
Package Weight (Metric)
29.1210 kg
69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 4. Housing Size 5.

69TCJS4-5-4

69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 4. Housing Size 5.
69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size Q. Copper Connector. 365 T C B N B

69TCJS1Q2365TCBNB

69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size Q. Copper Connector. 365 T C B N B
69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size Q. Copper Connector. 335 R C B N B

69TCJS1Q2335RCBNB

69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size Q. Copper Connector. 335 R C B N B
69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size Q. Copper Connector. 335365 U C B N B

69TCJS1Q2335365UCBNB

69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size Q. Copper Connector. 335365 U C B N B
69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size P. B 3 6 5 N C B N B

69TCJS1PB365NCBNB

69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 1. Housing Size P. B 3 6 5 N C B N B
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Aluminum, Connector Code 42P - Conductor Diameter Range - 1.146-1.220 inch (29.11-30.99mm), Heatsink Bore - N - 1.500 inch Diameter. Type Shield - E - Lead, Metallic Screen Continuity Kit - E - 4/0 Bonding Cable 6 foot quantity 4 with Split Bolts quantity 8, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink

69TCJS1Q142PNEENB

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Aluminum, Connector Code 42P - Conductor Diameter Range - 1.146-1.220 inch (29.11-30.99mm), Heatsink Bore - N - 1.500 inch Diameter. Type Shield - E - Lead, Metallic Screen Continuity Kit - E - 4/0 Bonding Cable 6 foot quantity 4 with Split Bolts quantity 8, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size N Bore Diameter at Jacket/Insulation Transition 1.390. Connector Type - Aluminum/No connector required, Connector Code 38P - Conductor Diameter Range - .936-1.011 inch (23.77-25.68mm), Heatsink Bore - N - 1.500 inch Diameter.Type Shield - N - Unknown, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - N - not required

69TCJS1NA38PNNNNN

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size N Bore Diameter at Jacket/Insulation Transition 1.390. Connector Type - Aluminum/No connector required, Connector Code 38P - Conductor Diameter Range - .936-1.011 inch (23.77-25.68mm), Heatsink Bore - N - 1.500 inch Diameter.Type Shield - N - Unknown, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - N - not required
69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 4, Housing Size 4, Connector type Copper/no connector required, Connector Code 53P - Conductor Diameter Range - 1.606-1.647 inch (40.79-41.83mm), Heatsink Size 5 - Outside Diameter 2.750 inch ( 69.85mm), Heatsink Bore - R - 1.687 inch Diameter. Type Shield - D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink, standard package

69TCJN44B53P5RDNNB

69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 4, Housing Size 4, Connector type Copper/no connector required, Connector Code 53P - Conductor Diameter Range - 1.606-1.647 inch (40.79-41.83mm), Heatsink Size 5 - Outside Diameter 2.750 inch ( 69.85mm), Heatsink Bore - R - 1.687 inch Diameter. Type Shield - D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink, standard package

Frequently Asked Questions

What cable types are compatible with TCJ joints?

TCJ transmission cable joints are designed for use on solid dielectric cables.

What are the dimensions of the 69TCJS1Q joint housing?

The joint housing for 69TCJS1Q has a diameter of 4.75 inches and a length of 22.48 inches.

What is the BIL rating for 138 kV class TCJ joints?

The Basic Impulse Level (BIL) rating for 138 kV class TCJ joints is 650 kV.

What is the minimum corona extinction voltage for 69 kV joints?

The minimum corona extinction voltage for 69 kV class joints is 60 kV (at 3 pC sensitivity).

What is the maximum system voltage for a 69 kV class joint?

The maximum system voltage for a 69 kV class joint is 72.5 kV.

What is the maximum continuous conductor temperature?

The maximum continuous conductor temperature for these joints is 90 °C.

What is the insulation diameter range for 69TCJS1Q?

The insulation diameter range for the 69TCJS1Q is 1.995 inches to 2.300 inches.

Do TCJ joints require field molding or tape?

No, field molds, wrapping machines, or pre-stretch are not required. Molding is done in the factory, reducing on-site time.

What voltage systems are compatible with TCJ joints?

TCJ transmission cable joints are designed for 46 kV through 138 kV class systems.

What insulation diameter range do TCJ joints support?

For Style 1 (through 69 kV), insulation diameters are 1.43 inches to 2.58 inches. For Style 4 (through 138 kV), they are 2.25 inches to 3.62 inches.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.