ABB - Installation Products 675ETPSP-M2380-DRG - 900 Amp, DeadBreak, 15KV, Window-Op Elbow Kit, Copper, Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

ABB Installation Products 675ETPSP-M2380-DRG 900 Amp, DeadBreak, 15KV, Window-Op Elbow Kit, Copper, Cable Insulation Diameter 1.370…

UPC: 783786442492


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Installation Products 675ETPSP-M2380-DRG is a 900 Amp DeadBreak elbow kit designed for 15KV medium-voltage applications. This fully shielded, dead-front connector provides a secure, insulated connection point for submersible cable systems in industrial, utility, and substation environments. The kit includes a copper compression lug and accommodates cable insulation diameters from 1.370 inches to 1.630 inches. It supports compressed stranded conductors up to 700/750 kcmil and compacted solid conductors up to 900 kcmil. Engineered to meet ANSI/IEEE Standard 386, the 675ETPSP-M2380-DRG delivers robust performance with a continuous current rating of 900 Amps and a momentary rating of 25kA symmetrical for 10 cycles. Its 100% peroxide-cured EPDM housing ensures durability and resistance to environmental stressors. The fully shielded construction prevents corona discharge and ensures safe operation at up to 14.4kV phase-to-phase and 8.3kV phase-to-ground voltages. The DeadBreak design allows for safe connection and disconnection under de-energized conditions using standard hand tools. Key applications include terminating medium-voltage cables in high-voltage apparatus, submersible systems, and industrial power distribution networks. The kit is compatible with Elastimold® accessories such as the K675CP, K675BIP, and K675RTP for expanded functionality, including visible separation, bypass, isolation, and grounding. For metallic tape shield or drain wire cables, an ECS cable seal grounding device is recommended to ensure proper shielding integrity. This DeadBreak elbow kit is a critical component for maintaining reliable, insulated connections in medium-voltage power distribution systems where safety and performance are paramount. Manufacturer SKU: 675ETPSP-M2380-DRG.
  • 900 Amp continuous current rating
  • 15KV voltage class
  • Accommodates cable insulation diameter from 1.370" to 1.630"
  • Supports compressed stranded conductors up to 700/750 kcmil and compacted solid conductors up to 900 kcmil
  • Includes copper compression lug and fully shielded, dead-front construction

Specifications

Amperage Rating
900 A
Application
900 Amps, 15kV
Color
Black
Conductor Range
700 to 750 STR/COMPR kcmil , 900 SOL/COMPT kcmil
Connection
Compression
Insulation
EPDM Rubber
Material
Housing - EPDM-Rubber
Size
Cable Insulation Diameter 1.370 inch to 1.630 inch
Special Features
Includes Insulated Cap and Sealing Kit
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Window-Op Connector
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15kV, 600 Amp - 200 Amp Combo T, carries current. Combo Elbow with bus, stud and cable adapter and lug kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

656CEPT-M5380

15kV, 600 Amp - 200 Amp Combo T, carries current. Combo Elbow with bus, stud and cable adapter and lug kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
600 Amp, Dead Break, Elbow Connector, Window-Op Connector Kit with Capacitive Test Point, 15KV, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

656ETP-H0270

600 Amp, Dead Break, Elbow Connector, Window-Op Connector Kit with Capacitive Test Point, 15KV, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
600 Amp, Dead Break, Elbow Connector, Test and Ground Connector Kit withCapacitive Test Point, 15KV, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 700/750, Solid 900. 200ECS Jacket Seal Included.

656ETP-M0380-DRG-S

600 Amp, Dead Break, Elbow Connector, Test and Ground Connector Kit withCapacitive Test Point, 15KV, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 700/750, Solid 900. 200ECS Jacket Seal Included.
600 Amp, Dead Break, Elbow Connector, Test and Ground Connector Kit withCapacitive Test Point, 15KV, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 500 /Solid 600 /mmSquared 250/300. 200ECS-G2 Jacket Seal and Grounding Kit Included.

656ETP-K0330DRGSG2-2

600 Amp, Dead Break, Elbow Connector, Test and Ground Connector Kit withCapacitive Test Point, 15KV, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 500 /Solid 600 /mmSquared 250/300. 200ECS-G2 Jacket Seal and Grounding Kit Included.
600 Amp, 25KV, DeadBreak, Elbow Connctor, Test and Ground Connector Kit, with Insulated Cap, Reducing Tap Plug, Elbow Housing, Cable Adapter, and Lug, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 600 /Compacted Solid 700.

K655ETP-K0350-DRG

600 Amp, 25KV, DeadBreak, Elbow Connctor, Test and Ground Connector Kit, with Insulated Cap, Reducing Tap Plug, Elbow Housing, Cable Adapter, and Lug, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 600 /Compacted Solid 700.
600 Amp, Dead Break, Elbow Connector, Test and Ground Connector Kit with Capacitive Test Point, 15KV, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

656ETP-F0230-DRG-S

600 Amp, Dead Break, Elbow Connector, Test and Ground Connector Kit with Capacitive Test Point, 15KV, Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
600 Amp, Test and Ground Connector Kit, 35KV, DeadBreak, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

755ETP-J0230-DRG

600 Amp, Test and Ground Connector Kit, 35KV, DeadBreak, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
600 Amp, 25KV, DeadBreak, Elbow Connctor, Test and Ground Connector Kit, with Insulated Cap, Reducing Tap Plug, Elbow Housing, Cable Adapter, and Lug, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

K655ETPL0320DRGSG3

600 Amp, 25KV, DeadBreak, Elbow Connctor, Test and Ground Connector Kit, with Insulated Cap, Reducing Tap Plug, Elbow Housing, Cable Adapter, and Lug, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

Frequently Asked Questions

How do I order the 675ETP with a loose stud?

To order the 675ETP with a loose stud, add the suffix "S" to the part number.

How do I order the 675ETP with a factory-assembled stud?

To order the 675ETP with a factory-assembled stud, add "SP" to the part number.

What items are included in the 675ETP kit?

Each kit contains one 675ETP Bushing Insert, one 1601-APC-1 Protective shipping cap, two 82-08 Lubricants, and one IS-0766 Installation Instruction.

How can I visually check for proper installation?

A Seating Indicator provides a visual check to ensure mating components are properly installed.

Can the loadbreak interface be operated when energized?

Yes, the loadbreak interface is designed for energized operation.

What are the current ratings for the 900A deadbreak interface?

The 900A deadbreak interface has a 900 Amp continuous rating and a 25kA Sym 10 cycle momentary rating.

What are the current ratings for the 200A loadbreak interface?

The 200A loadbreak interface has a 200 Amp continuous and loadbreak rating, and a 10kA Sym 10 cycle momentary & fault close rating.

What is the primary function of the 675ETP tap plug?

The 675ETP elbow tap plug allows a 200 Amp tap from a mating 900 Amp connector.

What are the maximum operating voltages for the 675ETP?

The maximum operating voltages are 8.3kV phase-to-ground and 14.4kV phase-to-phase.

What products are compatible with the 675ETP tap plug?

The 675ETP mates with K675BLR, K675BE, 167DR, 167DRG, 167ESA-XX, 165LR, 165LRJS, 167ELR, 167RLR, 167DLR, 167DELR, and 160GLR.

How to Install the LINK-C Deadbreak Cam Link Operable Connector System

This guide provides step-by-step instructions for the safe installation and setup of the LINK-C 600 amp deadbreak cam link operable connector system, including mounting, wiring, and grounding procedures. Ensure all apparatus are de-energized before starting.

Estimated time: 1h 30m

Tools needed:

Torque wrench, 1 inch hex socket, Hot stick, Wire strippers, Welding equipment (if using welded studs)

Supplies needed:

600 amp elbow, Stand-off plug (SOP), 3/8-16 hex nuts, Lockwashers, 3/8-16 x 2 inch studs, ELASTIMOLD supplied lubricant, 600 amp bushing extender, Retainer contact, Alignment bracket, Bushing extender clamp hardware, Elbow clamp hardware, LINK-C connector, #14 AWG or #12 AWG solid copper wire, Appropriate grounding connectors, Mating 200 amp product (optional), HV insulated cap (if no mating product)

  1. Prepare the 600 Amp Elbow and Determine Mounting Type

    Install the 600 amp elbow onto the cable according to its specific installation instructions, ensuring it will align with the stand-off plug. Next, determine if you will be installing with a bolted stand-off plug or an alignment bracket. This guide proceeds with the bolted stand-off plug method.

  2. Install the Mounted Stand-Off Plug (If Applicable)

    Weld three 3/8-16 x 2 inch studs to the faceplate per customer standard practice. Install three hex nuts onto the studs to support the stand-off plug, ensuring it aligns with the bushing. Place the stand-off plug over the studs, resting on the nuts. Secure the stand-off plug by installing a lockwasher and hex nut on each stud, then tighten to 12 ft-lbs. Verify that the top surfaces of the bushing and stand-off plug are in-line; readjust nuts if necessary.

  3. Install Bushing Extender and Elbow

    Clean and thoroughly lubricate the apparatus bushing and both interfaces of the 600 amp bushing extender with ELASTIMOLD lubricant. Install the bushing extender onto the apparatus bushing. Insert the 600ATM (Retainer Contact Operating Tool) into the retainer contact, engage its internal hex broach, and then insert the retainer contact into the bushing extender. Thread it into the apparatus bushing using a suitable tool on the 1 inch hex portion of the 600ATM, torquing to 50-60 ft-lbs. Repeat the cleaning and lubrication process for the epoxy standoff plug and both interfaces of the 600 amp elbow. Install the elbow onto the epoxy standoff plug, inserting the 600AMT (Retainer Contact Operating Tool) into the retainer contact and threading it into the epoxy standoff plug, torquing to 50-60 ft-lbs.

  4. Install the Alignment Bracket

    Remove the bushing extender clamp and elbow clamp from the alignment bracket. Position the alignment bracket on the bushing extender, measuring 2.5 inches (63.5mm) from the grounding eye. Assemble the bushing extender clamp to the alignment bracket with the supplied hardware, torquing by alternating sides until the clamp tabs are flush and tight. Next, position the elbow in the alignment bracket so that the elbow cuff is evenly lined up with the bushing extender cuff. Assemble the elbow clamp to the alignment bracket with the supplied hardware, torquing by alternating sides until the clamp tabs are flush and tight. Ensure the elbow clamp notch faces the cable entrance of the elbow.

  5. Insert the LINK-C Connector

    Clean and thoroughly lubricate both 600 ampere interfaces of the LINK-C connector with ELASTIMOLD lubricant. Align the Link so it is perpendicular to the switch faceplate when inserted. Insert the Link into the bushing extender and elbow, ensuring both lever arms are on the inside of the alignment bracket legs. Engage the pivot pin into the slots in the alignment bracket legs. While pushing inward, use a hot stick to move the lever arms downward, engaging the roller pin and moving the Link inward until the lever arms are perpendicular to the alignment bracket leg.

  6. Ground the System and Install Mating Products

    Ground the elbow by feeding a #14 AWG or #12 AWG solid copper wire through its grounding eye, twisting it tight, and connecting it to ground. Clean and lubricate the 200 amp interface on the Link. Ground and then install the desired mating product (e.g., loadbreak elbow, insulated cap) onto the 200 amp interface according to its specific installation instructions. Finally, ground the cable: if using concentric neutral cable, twist the wires together and connect to ground; if using 20MA or 21MA grounding devices, connect their ground lead to ground. For three-phase installations, tie all grounds from all three phases to a common ground point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.