ABB - Installation Products 656RETP-L0320-DRG - 600 Series Elbows with IEE Conductor Size AWG or kcmil, Compressed Stranded 1000. E 386 Capacitive Test Points, 600 Amp, 15kV, Test and Ground Replacement Elbow Connector Kit. Insulated Cap. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550.

ABB Installation Products 656RETP-L0320-DRG 600 Series Elbows with IEE Conductor Size AWG or kcmil, Compressed Stranded 1000. E 386…

UPC: 783786265329


Documents & Media
Installation InstructionsManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This ABB 600 Series Elbow Connector Kit, SKU 656RETP-L0320-DRG, is designed for 15kV applications and rated for 600 Amps. It features IEE conductor size compatibility for compressed stranded conductors ranging from AWG or kcmil 1000, and compacted solid conductors from 450/500/550 kcmil. The kit includes E 386 capacitive test points for safe testing and grounding procedures. The insulated cap ensures proper insulation integrity. Cable insulation diameters accommodated by this elbow connector range from 1.180 inches to 1.465 inches. It utilizes an aluminum compression lug for secure conductor termination. This connector kit is suitable for applications requiring reliable and safe termination of medium-voltage power cables. The UNSPSC code for this product is 26121630. ABB Installation Products is the manufacturer.
  • 15kV voltage rating
  • 600 Amp current rating
  • Accommodates cable insulation diameters from 1.180" to 1.465"
  • Includes E 386 capacitive test points
  • Aluminum compression lug for conductor termination

Specifications

Application
400 Amps
Connection
Compression
Material
Aluminum
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Elbow with Test Point
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
600 Series Elbow with out Test Point, With Stud, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 500 /Solid 600 /mmSquared 250/300.

K655BLR-K0330

600 Series Elbow with out Test Point, With Stud, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 500 /Solid 600 /mmSquared 250/300.
200 Amp, 15kV, Insulated Cap with Ground, Equipped with Insulated Cuff. Ground Lead Length 38 inch and Black.

167DRG(3)

200 Amp, 15kV, Insulated Cap with Ground, Equipped with Insulated Cuff. Ground Lead Length 38 inch and Black.
Base Bracket for K650J3, 15/25kV, 600 Amps. 3 Junction, 2 Welded Parking Stands.

600-402-2WD

Base Bracket for K650J3, 15/25kV, 600 Amps. 3 Junction, 2 Welded Parking Stands.
Grounding Kit, includes Constant Force Spring, Copper Foil Tape, Copper Braid, Butyl Auto Tape, Grounding Rod and Connector Strip Assembly

600-G2-2

Grounding Kit, includes Constant Force Spring, Copper Foil Tape, Copper Braid, Butyl Auto Tape, Grounding Rod and Connector Strip Assembly
15/25/35 kV, Copper Foil Tape - Cut, Carries Very Low Current. 6 inch Length, 0.375 inch Wide, 0.0026 inch Thick. Pressure Sensitive Conductive Acrylic Adhesive Tape with Backing.

200-28-1

15/25/35 kV, Copper Foil Tape - Cut, Carries Very Low Current. 6 inch Length, 0.375 inch Wide, 0.0026 inch Thick. Pressure Sensitive Conductive Acrylic Adhesive Tape with Backing.
Shield Plate, J3, 304 Stainless Steel, 12 inch x 3.5 inch x 16 Gage thick. No Holes.

650-278-2

Shield Plate, J3, 304 Stainless Steel, 12 inch x 3.5 inch x 16 Gage thick. No Holes.
Base Plate, 600 Amp Junctions, 15 inch x 6-3/4 inch x 5/8 inch thick with notched corners. 304 Stainless Steel. Two Rows of Three Slots 1 inch x 9/16 inch on 6 inch x 5-1/2 inch Centers.

600-403-1

Base Plate, 600 Amp Junctions, 15 inch x 6-3/4 inch x 5/8 inch thick with notched corners. 304 Stainless Steel. Two Rows of Three Slots 1 inch x 9/16 inch on 6 inch x 5-1/2 inch Centers.
Grounding Rod Adapter Assembly, Size N - Insulation Diameter Range 1.515 to 1.780 inch. includes Silicone Lubricant, Molded Housing, Grounding Rod and Instruction Sheet.

21MA-N

Grounding Rod Adapter Assembly, Size N - Insulation Diameter Range 1.515 to 1.780 inch. includes Silicone Lubricant, Molded Housing, Grounding Rod and Instruction Sheet.

How to Install the LINK-C Deadbreak Cam Link Operable Connector System

This guide provides step-by-step instructions for the safe installation and setup of the LINK-C 600 amp deadbreak cam link operable connector system, including mounting, wiring, and grounding procedures.

Estimated time: 1h

Tools needed:

Torque wrench, Socket wrench (1 inch hex), Hot stick, Wire strippers, 600ATM Operating Tool

Supplies needed:

ELASTIMOLD supplied lubricant, #14 AWG or #12 AWG solid copper wire, Appropriate grounding connector, HV insulated cap(s) or connector(s) (if replacing shipping covers)

  1. Prepare for Installation and Ensure Safety

    DANGER: Ensure all apparatus is de-energized before beginning installation or removal of any parts. This product must only be installed by competent personnel trained in high voltage electrical equipment safety practices. Inspect all parts for damage, proper rating, and compatibility with mating components. If supplied with protective shipping covers, remove them and replace with appropriate HV insulated caps or connectors before energizing or submerging the circuit. Read all instructions thoroughly before starting.

  2. Install the 600 Amp Elbow onto the Cable

    Install the 600 amp elbow onto the cable according to the specific installation instructions provided with the elbow. Ensure it is positioned to properly align with the stand-off plug or apparatus bushing.

  3. Install the Bushing Extender

    Clean and thoroughly lubricate the apparatus bushing and both interfaces of the 600 amp bushing extender using ELASTIMOLD supplied lubricant. Insert the 600ATM Operating Tool into the retainer contact and engage its internal hex broach. Install the bushing extender onto the apparatus bushing. Insert the retainer contact into the bushing extender and thread it into the apparatus bushing using a suitable tool applied to the 1-inch hex portion of the 600ATM Operating Tool. Torque to 50-60 ft-lbs.

  4. Install the 600 Amp Elbow onto the Epoxy Standoff Plug

    Clean and thoroughly lubricate the epoxy standoff plug and both interfaces of the 600 amp elbow with ELASTIMOLD supplied lubricant. Insert the 600ATM Operating Tool into the retainer contact and engage its internal hex broach. Install the elbow onto the epoxy standoff plug. Insert the retainer contact into the 600 amp elbow through the hole in the compression lug and thread it into the epoxy standoff plug using a suitable tool applied to the 1-inch hex portion of the 600ATM Operating Tool. Torque to 50-60 ft-lbs.

  5. Install the Alignment Bracket

    Remove the bushing extender clamp and elbow clamp from the alignment bracket. Position the alignment bracket on the bushing extender at a dimension of 2.5 inches (63.5mm) from the grounding eye. Assemble the bushing extender clamp to the alignment bracket with the supplied hardware, torquing by alternating sides until the clamp tabs are flush and tight on both sides.

  6. Position and Secure the Elbow in the Alignment Bracket

    Position the elbow in the alignment bracket so that the elbow cuff is lined up evenly with the bushing extender cuff. Assemble the elbow clamp to the alignment bracket with the supplied hardware, torquing by alternating sides until the clamp tabs are flush and tight on both sides. Ensure the elbow clamp notch faces the cable entrance of the elbow.

  7. Insert and Engage the LINK-C Connector

    Clean and thoroughly lubricate both 600 ampere interfaces of the Link with ELASTIMOLD supplied lubricant. Align the Link so it is perpendicular to the switch faceplate when inserted into the bushing extender and elbow. Insert the Link, ensuring both lever arms are on the inside of the alignment bracket legs. Engage the pivot pin into the slots in the alignment bracket legs. While pushing inward, move the lever arms downward using a hot stick eye, engaging the roller pin and moving the Link inward. Continue moving lever arms until they are perpendicular to the alignment bracket leg.

  8. Ground the System and Install Mating Products

    Ground the elbow by feeding a #14 AWG or #12 AWG solid copper wire through the grounding eye, twisting it tight, and connecting it to ground. Clean and lubricate the 200 amp interface on the Link. Ground the cable: if using concentric neutral cable, twist the neutral wires together and connect to ground with an appropriate connector; if using 20MA or 21MA grounding devices, connect the ground lead to ground with a suitable connector. For three-phase installations, tie all grounds from all three phases to a common ground point. Install the desired 200 amp mating product onto the Link's 200 amp interface according to its specific instructions.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.