
ABB Installation Products 656CETP-M0380-DRG 15kV, 600 Amp Combo T, carries current. Combo Elbow with bus, stud and cable adapter…
UPC: 075114184373
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15kV voltage class, 600 Amp continuous deadbreak connection
- Accommodates cable insulation diameters from 1.370 to 1.630 inches
- Aluminum compression lug for 700/750 kcmil stranded or 900 kcmil solid conductors
- Meets ANSI/IEEE Standard 386 with 95kV BIL and 34kV AC withstand
- Reduced stack height and simple connection system for easier installation
Specifications
Amperage Rating | 600 A |
Application | 600 Amps, 15kV Connector |
Color | PBT |
Color | Black |
Conductor Range | 700 to 750 kcmil , 900 kcmil |
Connection Type | Compression Lug, Elbow |
Connection Type | Compression Lug |
Current Rating | 600 A |
Environmental Conditions | All Weather Conditions |
Insulation | True |
Material | Housing - EPDM-Rubber |
Material | Aluminum, PBT |
Material | Aluminum |
Series | 656CETP |
Size | Cable Insulation Diameter 1.370 inch to 1.630 inch |
Size | 1.370-1.630 inch (cable insulation diameter), 700/750-900 kcmil (conductor size) |
Special Features | Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | ComboT Elbow |
Voltage Rating | 15 kV |
Voltage Rating | 15kV |
Width | 13.31 in |
Width | 338.074 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

655CETPNM0380S
600 Amp, 15kV, Combo T Elbow Reducing Tap Plug without Stud, with Cable Adapter, Lug, No Test Point, Aluminum, Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. With Shrink-Fit Jacket Seal Kit.
656CETP-L0330
15kV, 600 Amp Combo T, carries current. Combo Elbow with bus, stud and cable adapter, lug and insulated cap kit. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
656CETP-L0330-S
15kV, 600 Series ComboT Elbow with 200 Amp Reducing Tap Plug, Stud, Cable Adapter and Lug Kit with Test Point and Seal. Cable Insulation Diameter 1.180 - 1.465 inches (30.0-37.2mm). Aluminum Compression Lug. Conductor Size 330 - 500 kcmil Stranded/Compressed or 600 kcmil Solid/Compact. Kit Includes Elbow Connector Housing, Stud, Lug, Tube of Lubricant, Cable Adapter, Crimp Chart and Installation Instructions.
656CETP-M0360-DRG
15kV, 600 Amp Combo T, carries current. Combo Elbow with bus, stud and cable adapter, lug and insulated cap kit. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 650 /Compacted Solid 750 /mmSquared Compact 400.
656CETP-L0330-DRG
15kV, 600 Amp Combo T. Combo Elbow with bus, stud and cable adapter, lug and insulated cap kit. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Compression Lug. Conductor Size Compressed Stranded 500 kcmil or Compacted Solid 600 kcmil. Includes Insulated Cap.
656CETP-K5330-SG3
15kV, 600 Amp Combo T, carries current. Combo Elbow with bus, stud and cable adapter, lug and insulated cap kit. Cable Insulation Diameter 1.090 inch to 1.310 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
656CETP-L0270-DRG
15kV, 600 Amp, Combo T Reducing Tap Plug with Stud, Cable Adapter, Lug and Insulated Cap Kit. Cable Insulation 1.180-1.465 inches. Aluminum Connector Type, Connector Size 4/0 Stranded/Compressed or 500 Compact/Solid. With Insulated Cap. With Test Point.
656CETP-K0330-DRG
15kV, 600 Amp Combo T. Combo Elbow with bus, stud and cable adapter, lug and insulated cap kit. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size Compressed Stranded 500 kcmil or Compacted Solid 600 kcmil. Includes Insulated Cap.Frequently Asked Questions
What is the primary safety precaution for ComboT installation?
The system must be de-energized before initiating any ComboT installation. Always refer to the complete instruction sheet.
What is the primary safety precaution for ComboT installation?
The system must be de-energized before initiating any ComboT installation. Always refer to the complete instruction sheet.
How much stack height does the ComboT reduce?
Each combination elbow/connecting plug reduces the stack height by 2.67 inches.
What is the cable insulation diameter range for ComboT?
The cable insulation diameter range for ComboT connectors is from 0.42 inches to 1.935 inches.
What is the torque specification for the 600ATM in CCP installation?
During CCP installation, the 600ATM should be torqued to 50 to 60 ft.-lbs.
What stud size is used for ComboT assembly?
ComboT assembly utilizes a standard 5/8 in–11 stud that threads into the equipment bushing.
What are the continuous current ratings for CCP/CBW connectors?
CCP/CBW connectors have continuous current ratings of 600 A or 900 A.
What are the voltage ratings for K655/K656 CCP/CBW series?
The K655/K656 CCP/CBW series has a max phase-to-ground operating voltage of 16.2 kV and a max phase-to-phase operating voltage of 28.0 kV.
What are the continuous current ratings for CETP connectors?
CETP connectors have continuous current ratings of 600 A for deadbreak and 200 A for loadbreak, or 900 A for deadbreak and 200 A for loadbreak.
What are the voltage ratings for 25 kV CETP series?
The 25 kV CETP series has a max phase-to-ground operating voltage of 15.2 kV and a max phase-to-phase operating voltage of 26.3 kV.
How to Install the 656CETP Deadbreak Elbow Connector
This guide provides detailed instructions for the installation, cable preparation, and connection of the 656CETP Deadbreak Elbow Connector on 15kV class systems, including safety warnings and voltage testing procedures.
Estimated time: 1h 30m
Tools needed:
Hotstick, 600AT assembly tool (for products dated Sep 30, 2013 or earlier), 600ATM assembly tool (for products dated Oct 1, 2013 or later), Wire brush (for aluminum conductors), Suitable sensing device (for voltage test), Crimping tool, Wire strippers
Supplies needed:
656CETP Elbow Connector, Cable Adapter, Compression Lug, Lubricant, Vinyl plastic tape, Suitable connector for ground wire, Insulated cap (for test point, if applicable)
- Perform Initial Safety Checks and Inspections
DANGER: Ensure all apparatus are de-energized before installation or removal of any parts. Inspect all product components for damage, verify their ratings, and confirm compatibility with mating parts. This product must be installed only by competent personnel trained in high voltage electrical equipment safety practices. Failure to follow these instructions will result in damage to the product and serious or fatal injury.
- Position and Clean the Cable
Position the cable in its final assembled location, ensuring enough slack for elbow removal. For concentric neutral cable, unwind the concentric neutral wires. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product. Thoroughly clean the outer surface of the cable for a distance of 24 inches (610mm) or up to the bent-back concentric neutral wires.
- Prepare Cable Jacket and Shield
Follow the instructions that apply to your cable type: A. Remove the outer jacket to the specified dimension. B. Fold back shield wires. C. Remove flat metallic tape shield and secure with vinyl plastic tape to the specified dimension. D. Remove fabric tape shield and install tape retainer and tape marker to dimensions shown. E. Remove longitudinally corrugated shield and install tape marker to dimension shown. F. For UNISHIELD® or Lead Sheath cable, refer to the Installation Instructions supplied with the 10TL cable shield adapter. G. Remove semi-con shield and install tape marker to dimensions shown, ensuring not to cut or nick the cable insulation.
- Bevel Insulation and Install Cable Adapter
Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean and then lubricate the cable insulation, always working toward the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.
- Prepare the Conductor
Remove the protruding cable insulation by cutting it even with the end of the cable adapter. Exercise caution not to cut or nick the cable adapter or the conductor. The length of the exposed conductor should measure between 4-3/8 inches and 4-11/16 inches (111mm-119mm). If the measurement is outside this range, redo the assembly.
- Install the Compression Lug
For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor immediately before fully inserting it into the compression lug. Measure the 'Check Dimension' before crimping; it should be less than 6-1/2 inches (165mm). Crimp the compression lug according to its supplied instructions. Wipe off any excess inhibitor from the lug and cable adapter surface after crimping. The distance from the end of the compression lug to the cable adapter after crimping should be 6-1/2 inches to 7-1/4 inches (165mm-184mm).
- Install the Elbow Connector
Lubricate the cable adapter and the inside of the elbow cable entrance using the supplied lubricant. Install the elbow onto the cable adapter until it cannot advance further. Ensure the cable adapter remains flush with the tape marker; reposition if necessary. Once the elbow is fully seated, remove the tape marker.
- Connect to Mating Product
WARNING: DO NOT CONNECT OR DISCONNECT MATING PRODUCTS WHILE ENERGIZED. DO NOT ENERGIZE WHILE DISCONNECTED. Remove protective caps from the elbow and the mating part. Install the stud into the apparatus by hand until it is fully seated. Clean and lubricate both the elbow and the mating part with the supplied lubricant. Push the elbow onto the mating part. For products dated September 30, 2013 or earlier, use the 600AT assembly tool to torque the contact assembly until the torque limiter ratchets (19 to 25 ft/lbs). For products dated October 1, 2013 or later, use the 600ATM assembly tool to tighten the contact assembly to 50-60 ft/lbs torque, but DO NOT EXCEED 60 ft/lbs.
- Ground the Cable Shield and Waterproof Jacket
Insert one end of a wire, with ampacity at least equivalent to No. 14 AWG Copper, through the grounding eye and twist to form a small loop without damaging the eye. Connect this wire to ground using a suitable connector. The cable shield must be grounded according to the instructions supplied with the grounding device, or via an alternate method if no device is used. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.
- Install Loadbreak Interface (If Applicable)
Clean and lubricate the entire loadbreak interface and the mating connector (such as a DR(G), ESA, GLR, or LR of the appropriate voltage class) with the supplied or ELASTIMOLD® approved lubricant. Install the mating connector to the tap plug interface following the instructions provided with that specific product.
- Verify Seating Indication
Confirm the complete assembly of an insulated cap or elbow by ensuring that no portion of the colored interface sleeve is visible when viewed from the side. This indicates full seating.
- Perform Voltage Test (656CETP Specific)
To test if the circuit is energized, remove the test point cap with a hotstick, peeling it off at an angle. WARNING: The voltage test point is a capacitance device, not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device designed for capacitive test points. Contamination or incorrect equipment can give a false 'no voltage' indication; treat the elbow as energized until confirmed by other means to prevent serious injury. After testing, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.