ABB Installation Products 756LR-L0270-S 35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and…
UPC: 783786400614
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Fully rated 35kV, 600 Amp Deadbreak Elbow Connector with integrated test point.
- Fully shielded, fully submersible molded rubber housing constructed from 100% peroxide-cured EPDM.
- Accommodates cable insulation diameters from 1.180" to 1.465" and conductor sizes 4/0 AWG to 250 kcmil.
- Includes aluminum compression lug and cold-shrinkable jacket seal for secure termination and environmental protection.
- Meets ANSI/IEEE Standard 386, rated for 21.1kV Max Phase-to-Ground and 150kV BIL.
Specifications
Amperage Rating | 600 A |
Application | 35 kv, 600 Amp |
Color | Black |
Conductor Range | 4/0 STR/COMPR AWG , 250 kcmil |
Connection | Compression |
Connection Type | Deadbreak Elbow with Test Point |
Environmental Conditions | Fully Submersible |
Insulation | True |
Material | Housing - EPDM-Rubber |
Material | Aluminum Compression Lug |
Series | 600 Series |
Size | 1.180 inch to 1.465 inch Cable Insulation Diameter |
Special Features | 35kV, 600 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Can be easily connected or disconnected using standard hand tools and equipment in a de-energized state. S - Cold-Shrinkable Jacket Seal |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Deadbreak Elbow Connector with Test Point |
Voltage Rating | 35 kV |
Voltage Rating | 35kV |
Width | 12.28 in |
Width | 311.912 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 9.0000 L |
Package Weight (Metric) | 4.0820 kg |

375LR-L-2270
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
756LR-L0260-S
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 3/0 /Compacted Solid 4/0 /mmSquared Compact 95. Cold-Shrinkable Jacket Seal Included.
756LR-K2290-SG3
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Copper Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded 300 /Compacted Solid 350 /mmSquared Compact 150. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
756LR-L0240-S
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG Compressed Stranded 1/0 or Compacted Solid 2/0. Cold-Shrinkable Jacket Seal Included.
756LR-L0240
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 1/0 /Compacted Solid 2/0.
756LR-K0330-S
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300. Cold-Shrinkable Jacket Seal Included.
756LR-K2230-SG3
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Copper Compression Lug. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size AWG or kcmil, Compressed Stranded #1/ Compacted Solid 1/0 /mmSquared Compact 50. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.
756LR-L0250
35kV 600 Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Aluminum Compression Lug. Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size AWG or kcmil, Compressed Stranded 2/0 /Compacted Solid 3/0 /mmSquared Compact 70.Frequently Asked Questions
What is the primary application of the 756LR elbow connector?
The 756LR is designed to provide fully shielded, dead-front submersible cable connections to high-voltage apparatus.
What standard does the 756LR elbow connector meet?
The 756LR elbow connector meets ANSI/IEEE Standard 386, Latest Revision.
What is the impulse withstand rating of the connector?
The impulse withstand rating is 150kV BIL (1.2 x 50 microsecond wave).
What items are included in a 756LR kit?
A kit contains the elbow connector housing, copper compression lug, stud, insulated plug with cap, lubricant, cable adapter, and installation instructions.
What is recommended when using metallic tape shield cables?
An ECS cable seal grounding device is recommended when the 756LR is used on metallic tape shield or drain wire cable.
Is the 756LR connector submersible?
Yes, the 756LR features a fully shielded, fully submersible molded rubber housing.
What is the continuous current rating of the 756LR?
The continuous current rating for the 756LR elbow connector is 600 Amps.
What is the acceptable range for cable insulation diameters?
The connector supports cable insulation diameters ranging from 0.760 inches to 2.120 inches.
What conductor types and sizes are compatible with the 756LR?
It is compatible with #2 AWG to 1250 kcmil for both aluminum and copper conductors.
What is the maximum operating voltage for this connector?
The maximum phase-to-ground operating voltage for the 35kV class is 21.1kV.
How to Install 756LR/776LR Deadbreak Elbow Connectors
This guide provides step-by-step instructions for installing 756LR and 776LR Deadbreak Elbow Connectors. These connectors offer fully shielded, submersible deadfront cable connections for high-voltage apparatus on 35kV class systems, enabling splicing and tapping of 600-ampere or 900-ampere systems.
Estimated time: 2h
Tools needed:
Cutting tool, Wire strippers, Wire brush (for aluminum conductors), Crimping tool, Torque wrench, Hotstick, Capacitive voltage sensing device
Supplies needed:
756LR/776LR Elbow Connector Kit, Lubricant (silicone), Threaded stud (if not integrated), Grounding wire (No. 14 AWG Copper or equivalent), Grounding connector, Waterproofing material (recommended), Mating apparatus bushing
- De-energize and Inspect Apparatus
DANGER: Ensure all apparatus in the work area are de-energized before beginning installation; do not touch or move energized products. This product must be installed only by competent personnel trained in high voltage electrical safety. Inspect all kit contents and mating parts for damage, proper rating, and compatibility with the cable and other components. Remove any protective shipping covers and replace with appropriate HV insulated caps or connectors if the circuit will be submerged or energized.
- Prepare the Cable
Position the cable in its final assembled location, ensuring enough slack for elbow removal. Cut the cable 1-3/4 inches (45mm) from the centerline of the mating product. Clean the outer jacket of the cable for a distance of 24 inches (610mm). Refer to the specific instructions for your cable type (e.g., UNISHIELD, jacketed, non-jacketed) to remove the outer jacket and prepare the cable shield and insulation according to the provided diagrams and measurements.
- Install Cable Adapter and Prepare Conductor
Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4 inch (6mm) back. Thoroughly clean the cable insulation, then lubricate it working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker. Carefully remove the protruding cable insulation, cutting it even with the end of the cable adapter without nicking the adapter or conductor. The exposed conductor length must be between 4-3/8 inches (111mm) and 4-3/4 inches (121mm).
- Crimp the Compression Lug
For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor immediately before fully inserting it into the lug. Measure the 'Check Dimension' (must be less than 7 inches / 178mm) before crimping. Crimp the compression lug according to the instructions supplied with the lug. After crimping, wipe off all excess inhibitor from the lug and cable adapter surface. The distance from the end of the compression lug to the cable adapter should be between 6-7/8 inches (175mm) and 7-5/8 inches (194mm).
- Install the Elbow
Lubricate the cable adapter and the inside of the elbow's cable entrance. Install the elbow onto the cable adapter, pushing until it cannot advance further. Verify the cable adapter remains flush with the tape marker; reposition if necessary. Remove the tape marker.
- Connect to Mating Product
DANGER: Do not connect or disconnect mating products while energized, and do not energize while disconnected. Remove protective caps from both the elbow and the mating part. If the mating part lacks a stud, hand tighten the threaded stud supplied with the elbow into it. Clean and lubricate both the elbow and the mating part. Push the elbow onto the mating part, aligning the compression lug's hole with the stud. Clean and lubricate the mating part for the opposite end of the elbow, then insert it into the elbow, engage threads, and hand tighten. Torque the mating part according to its specific instructions.
- Install Insulating Plug and Ground the Cable
If using an insulating plug, clean and lubricate the inner surface of the voltage detection cap, then push it onto the elbow until it snaps into place. CAUTION: The insulating plug provides a means for detecting system voltage. Insert one end of a No. 14 AWG Copper (or equivalent) wire through the grounding eye, twist to form a small loop, and connect it to ground using a suitable connector. Ensure the cable shield is grounded according to instructions supplied with any grounding device, or via an alternate method. Waterproof the cable jacket at this point to prevent moisture ingress.
- Perform Voltage Test (If Applicable)
If the connector has an integral capacitance test point, remove the test point cap with a hotstick, peeling it off at an angle. WARNING: The voltage test point is a capacitance device, not directly connected to the conductor. Use a suitable sensing device designed for capacitive test points to determine if the cable is energized, following the device manufacturer's directions. Do not use conventional voltage measuring equipment. Treat the elbow as energized until a 'no voltage' indication is confirmed by other means to prevent serious or fatal injury. After testing, clean and lubricate the inside surface of the cap with silicone lubricant and replace it.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.