ABB - Installation Products 6010 K - Tin Plated Aluminum Mechanical Splice Flood Seal Kit, Contains One 61/64 inch long Mechanical Lug with 2 Screws tapped 5/16-24 UNF-2B, Flood Seal Cap with Liner and Rocket, and Oxide Inhibiting Compound. Wire Size #2 to #14 CU7AL. UL Listed.

ABB Installation Products 6010 K Tin Plated Aluminum Mechanical Splice Flood Seal Kit, Contains One 61/64 inch long…

UPC: 783786767854


Documents & Media
Installation InstructionsManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 6010 K Tin Plated Aluminum Mechanical Splice Flood Seal Kit is a UL-listed solution for terminating and splicing copper and aluminum wires ranging from #2 to #14 AWG. This kit includes one 61/64-inch mechanical lug with two 5/16-24 UNF-2B screws, a flood seal cap with liner and rocket, and oxide-inhibiting compound for corrosion resistance. The tin-plated aluminum construction ensures reliable conductivity and long-term performance in industrial and commercial applications. The flood seal design provides environmental protection against moisture and contaminants, making it suitable for use in harsh or outdoor environments. The mechanical lug’s screw design allows for secure, vibration-resistant connections without soldering or crimping. This kit is ideal for electrical contractors, maintenance teams, and OEMs requiring compliant, durable, and easy-to-install wire termination solutions. Compliance with UL standards ensures safety and reliability in critical electrical systems.
  • UL-listed mechanical splice kit for #2 to #14 AWG copper and aluminum wires
  • Includes 61/64-inch tin-plated aluminum mechanical lug with two 5/16-24 UNF-2B screws
  • Flood seal cap with liner and rocket for environmental protection against moisture and contaminants
  • Oxide-inhibiting compound included for corrosion resistance and reliable conductivity
  • Designed for secure, vibration-resistant connections without soldering or crimping

Specifications

Conductor Range
#2 to #14
Connection
Mechanical
Finish
Tinned
Insulation
True
Length
61/64 in
Material
Aluminum
Standard
UL Listed
Type
Mechanical Splice with Flood Seal
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
25kv, 600 Amp, Direct Test Straight Receptacle Elbow, Deadbreak, Cable Insulation Diameter 1.515-1.780. Aluminum Lug, Conductor Size 700/750 kcmil Stranded/Compressed or 800/900 kcmil Compact/Solid. Length 17 inches. Mates with K650SRA.

K655DSR-N0380

25kv, 600 Amp, Direct Test Straight Receptacle Elbow, Deadbreak, Cable Insulation Diameter 1.515-1.780. Aluminum Lug, Conductor Size 700/750 kcmil Stranded/Compressed or 800/900 kcmil Compact/Solid. Length 17 inches. Mates with K650SRA.
Single cable clamp 150-300mm2 for power terminal type 5

45000034

Single cable clamp 150-300mm2 for power terminal type 5
25kV, 600 Amps, Multi-way Connector. Three-Way. HAC01-HAC01-LAC01. H - Cable Insulation Diameter 0.850 inch to 1.050 inch. L - Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size Range AC01 for all Three-Ways Compressed / Stranded / Compacted / Solid #2 to 300 kcmil.

K656CY-DP0600831

25kV, 600 Amps, Multi-way Connector. Three-Way. HAC01-HAC01-LAC01. H - Cable Insulation Diameter 0.850 inch to 1.050 inch. L - Cable Insulation Diameter 1.180 inch to 1.465 inch. Conductor Size Range AC01 for all Three-Ways Compressed / Stranded / Compacted / Solid #2 to 300 kcmil.
15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size #2 Compressed or Stranded AWG or #1 Solid or Compact AWG. SG3 - Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.

168RLR-H5220-SG3

15kV 200 Amp, Loadbreak Replacement Elbow Connector with Test Point. Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug. Conductor Size #2 Compressed or Stranded AWG or #1 Solid or Compact AWG. SG3 - Cold-Shrinkable Seal with Copper Braid and Constant Force Spring.
15/25kV 200 Amp, Deadbreak Straight Plug, Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size #3 Compressed or Stranded AWG, or #2 Solid or Compact AWG or 26.67 mm2. Bails are required, but not included, order separately.

K151SP-A0210

15/25kV 200 Amp, Deadbreak Straight Plug, Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size #3 Compressed or Stranded AWG, or #2 Solid or Compact AWG or 26.67 mm2. Bails are required, but not included, order separately.
15/25kV 200 Amp, Deadbreak Straight Receptacle, Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size #3 Compressed or Stranded AWG, or #2 Solid or Compact AWG or 26.67 mm2. Bails are required, but not included, order separately. Length 9.54 inch. Widest point 2.74 inch.

K151SR-A0210

15/25kV 200 Amp, Deadbreak Straight Receptacle, Cable Insulation Diameter 0.575 inch to 0.740 inch. Aluminum Compression Lug. Conductor Size #3 Compressed or Stranded AWG, or #2 Solid or Compact AWG or 26.67 mm2. Bails are required, but not included, order separately. Length 9.54 inch. Widest point 2.74 inch.
Black PVC Coated Aluminum Flood Seal 125 Series Screw-on Transformer Connectors for Wire Size #12-500 kcmil, Stud size 5/8 inch, length 10-3/4 inch, Height 6-15/16 inch, Outlets 6. Bolt Holes per outlet is 2. Complete Assembly with Six CSN 2011 Insulating Rockets. Hardware included (12) 1/2-13 x 1 inch, and (1) 5/8-11 Steel Jam Nut.

FTU 6 NAWR

Black PVC Coated Aluminum Flood Seal 125 Series Screw-on Transformer Connectors for Wire Size #12-500 kcmil, Stud size 5/8 inch, length 10-3/4 inch, Height 6-15/16 inch, Outlets 6. Bolt Holes per outlet is 2. Complete Assembly with Six CSN 2011 Insulating Rockets. Hardware included (12) 1/2-13 x 1 inch, and (1) 5/8-11 Steel Jam Nut.
Aluminum Keebar, Screw-on, Transformer Connector, Stud 1 Inch. 8-1/4 inch long x 2-53/64 inch tall. Stainless Steel Hardware includes (12) 1/2 inch Belleville Washers, (12) 1/2 inch Flat Washers, (12) 1/2-13 Nuts, (6) Studs. Cap and Grease. Pad is 8-1/4 inch long x 1-1/4 inch x 1/2 inch thick and has Six holes tapped 1/2-13 UNC-2B on 1-3/8 inch centers.

SKB 1-6

Aluminum Keebar, Screw-on, Transformer Connector, Stud 1 Inch. 8-1/4 inch long x 2-53/64 inch tall. Stainless Steel Hardware includes (12) 1/2 inch Belleville Washers, (12) 1/2 inch Flat Washers, (12) 1/2-13 Nuts, (6) Studs. Cap and Grease. Pad is 8-1/4 inch long x 1-1/4 inch x 1/2 inch thick and has Six holes tapped 1/2-13 UNC-2B on 1-3/8 inch centers.

How to Install the Flood Seal® Submersible Splice Cover FSS 20 & FSS 20L

This guide provides instructions for installing the Flood Seal® Submersible Splice Cover, designed to maintain watertight integrity and full insulating value for low voltage cable splice joints, eliminating the need for taping. Installation must be performed by trained installers in accordance with all applicable electrical codes and safety rules to prevent electric shock.

Estimated time: 15m

Tools needed:

Cutting tool, Insulation beveling tool, Connector installation tool

Supplies needed:

Flood Seal® Submersible Splice Cover (FSS 20 or FSS 20L), Low voltage cable, Silicone grease, Electrical connector, Silicone sealant

  1. Select Correct Cut-Off Ring

    Select the correct cut-off ring on the rocket sleeve and cap that corresponds to the specific cable size being used for the splice.

  2. Cut Rocket Sleeve and Cap

    Cut off the rocket sleeve and cap at the tip of the arrow, ensuring that the correct cable size marking remains visible on the opened rocket and cap after the cut.

  3. Bevel Cable Insulation

    Bevel or pencil the cable insulation by 1/4 inch (6.35 mm) to facilitate easier installation and proper seating of the splice cover components.

  4. Apply Silicone Grease

    Apply a generous amount of silicone grease to the prepared cable insulation to aid in sliding the cover components and ensure a good seal.

  5. Slide Rocket and Cap Over Cable

    Slide the cut rocket sleeve and cap over the prepared cable, positioning it appropriately for the upcoming connector installation.

  6. Install Electrical Connector

    Install the electrical connector onto the prepared cable ends according to the connector manufacturer's instructions, ensuring a secure and proper connection.

  7. Assemble Flood Seal Housing

    Apply silicone sealant to the open edge of the rocket sleeve. Then, slide the two halves of the Flood Seal® Housing together, carefully centering it over the installed connection to create a watertight and fully insulated splice.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.