Authorized ABB Distributor (Installation Products)
ABB - Installation Products 35PCJ2K1240 - 35kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

ABB Installation Products 35PCJ2K1240 35kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable…

UPC: 783786271771


Documents & Media
BrochureManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 35kV Power Cable Joint, SKU 35PCJ2K1240, is a Style 2 termination designed for aluminum conductors. This joint system features a universal housing and separate cable adapters, providing flexibility for various installation requirements. It is engineered to accommodate cable insulation diameters ranging from 1.090 inches to 1.310 inches. The system supports stranded aluminum conductors sized 1/0 AWG and solid aluminum conductors sized 2/0 AWG. This product is part of ABB's Installation Products catalog, known for reliable electrical infrastructure components. The separate adapter design allows for precise fitting to specific cable dimensions, ensuring a secure and insulated connection. This joint is suitable for medium voltage power distribution applications where reliable cable termination is critical. The universal housing simplifies inventory management by accommodating a range of cable sizes within its specified insulation diameter range. This product facilitates safe and efficient splicing of power cables in industrial and utility settings. UNSPSC Code: 39121452.
  • 35kV rated power cable joint
  • Style 2 termination
  • Universal housing with separate cable adapters
  • Accommodates cable insulation diameters from 1.090" to 1.310"
  • Designed for 1/0 AWG stranded and 2/0 AWG solid aluminum conductors

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
1/0 STR AWG , 2/0 SOL AWG
Connection
Compression
Enclosure
Yes
Environmental Conditions
Fully Insulated, Shielded and Sealed for Direct-Burial, Vault, Submersible and other Severe Service Applications
Insulation
Yes
Material
EPDM Rubber
Number Of Conductors
2
Size
14-3/8 inch long
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Power Cable Joint
Voltage Rating
35 kV
Package Dimensions (L x W x H)
15.5 IN x 4.75 IN x 3.19 IN
Package Dimensions (L x W x H)
39.37 cm x 12.065 cm x 8.1026 cm
Package Weight (Imperial)
3.2500 L
Package Weight (Metric)
1.4740 kg
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0. Cold-Shrinkable Jacket Seal Included.

35PCJ1J1240-S

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0. Cold-Shrinkable Jacket Seal Included.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.900 inch to 2.120 inch. Aluminum Conductor. Conductor Size AWG Stranded 1250.

35PCJ1Q1440

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.900 inch to 2.120 inch. Aluminum Conductor. Conductor Size AWG Stranded 1250.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.900 inch to 2.120 inch. Copper Conductor. Conductor Size AWG Solid 1000.

35PCJ1Q2400

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.900 inch to 2.120 inch. Copper Conductor. Conductor Size AWG Solid 1000.
35kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.

35PCJ2J1230

35kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.900 inch to 2.120 inch. Copper Conductor. Conductor Size AWG Stranded 750.

35PCJ1Q2380

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.900 inch to 2.120 inch. Copper Conductor. Conductor Size AWG Stranded 750.
35kV Power Cable Joint Style 1, Cable Insulation Diameter 1.900 inch to 2.120 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1250. Cold Shrinkable Jacket Seal included.

35PCJ1Q1440-S

35kV Power Cable Joint Style 1, Cable Insulation Diameter 1.900 inch to 2.120 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1250. Cold Shrinkable Jacket Seal included.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 1000. With Sheild Adapter.

15PCJ2N2410-M2400-TL

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 1000. With Sheild Adapter.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Solid 750.

15PCJ2N2410-L2360

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Solid 750.

Frequently Asked Questions

What voltage classes are available for PCJ joints?

Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

How are transition joints catalog numbers constructed?

When constructing a catalog number for a transition joint, list the larger connector first and the smaller connector second.

What is the AC withstand for a 25 kV class joint?

For a 25 kV class joint, the AC withstand at 60 Hz for 1 minute is 52 kV.

Can copper connectors be used with aluminum conductors?

No, copper compression connectors are suitable for copper-to-copper connections only and should not be used on aluminum conductors.

What is the maximum cable insulation diameter for 35PCJ joints?

For 35PCJ joints, the maximum cable insulation diameter is 2.120 inches, corresponding to symbol Q.

What is the minimum overall length for a Style 1 joint?

The minimum overall length for a Style 1 joint is 10 1/4 inches, found in the 15PCJ1FX and 15PCJ1GX models.

What is the purpose of the grounding eye?

The grounding eye provides a convenient point to connect a ground wire to the molded conductive shield, placing it at ground potential.

What is the BIL impulse withstand for a 35 kV class joint?

For a 35 kV class joint, the BIL impulse withstand (1.2 x 50 μsec. wave) is 300 kV.

What standards do PCJ joints meet for safety?

The shield design meets IEEE 592 standard, and connectors meet ANSI 119.4 Class A and Class 3 ratings.

What is the short-time current rating?

The short-time current rating for these joints is equal to that of the cable rating, up to 35 kA.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.