Authorized ABB Distributor (Installation Products)
ABB - Installation Products 35PCJ1Q1440-S - 35kV Power Cable Joint Style 1, Cable Insulation Diameter 1.900 inch to 2.120 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1250. Cold Shrinkable Jacket Seal included.

ABB Installation Products 35PCJ1Q1440-S 35kV Power Cable Joint Style 1, Cable Insulation Diameter 1.900 inch to 2.120 inch.…

UPC: 783786338474


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 35PCJ1Q1440-S is a 35kV power cable joint engineered for medium-voltage applications requiring permanent, fully shielded, and fully submersible straight splices. This joint accommodates cable insulation diameters between 1.900 and 2.120 inches, making it suitable for 1250 kcmil compressed stranded conductors. The aluminum compression lug ensures secure electrical connectivity and mechanical strength, while the included cold shrinkable jacket seal provides an integrated, moisture-resistant barrier for long-term performance. Designed to meet IEEE Standard 404, the 35PCJ1Q1440-S delivers a 200kV BIL impulse withstand (1.2 x 50 microsecond wave), 69kV AC withstand, and 30kV AC corona extinction at 3pC sensitivity. Its continuous current rating matches the cable rating, with a short-time current rating up to 35kA. The molded conductive shield provides a virtually indestructible ground shield for true deadfront construction, eliminating the need for taping at the cable entrance. This joint is ideal for new installations to join cable runs or for repairs to broken cables in existing systems. It can be installed directly buried or in a vault, with a pin and socket interlock capable of withstanding pulls up to 500 lbs. The grounding eye allows convenient connection of a ground wire to the molded conductive shield, placing it at ground potential. Compatible with UD cable having concentric neutral and extruded insulation shielding, it also operates effectively on fabric tape shielded or lead-jacketed cables when used with the proper Elastimold® cable shield adapter or grounding device. The 35PCJ1Q1440-S simplifies installation with pre-engineered components, reducing field assembly complexity. Its compression lug design minimizes resistance and heat generation, reducing the risk of hot spots in high-load scenarios. Suitable for utility, industrial, and commercial power distribution systems where durability and ease of installation are critical.
  • 35kV voltage rating with 200kV BIL impulse withstand
  • Accommodates 1.900-2.120" cable insulation diameter
  • 1250 kcmil aluminum compression lug for secure connectivity
  • Fully shielded, fully submersible molded rubber housing
  • Cold shrinkable jacket seal for moisture resistance

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
1250 kcmil
Connection
Compression
Insulation
Yes
Material
EPDM Rubber
Number Of Conductors
2
Size
15-3/4 inch long
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
4.5900 L
Package Weight (Metric)
2.0820 kg
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.900 inch to 2.120 inch. Aluminum Conductor. Conductor Size AWG Stranded 1250.

35PCJ1Q1440

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.900 inch to 2.120 inch. Aluminum Conductor. Conductor Size AWG Stranded 1250.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 1000. With Sheild Adapter.

15PCJ2N2410-M2400-TL

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 1000. With Sheild Adapter.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Solid 750.

15PCJ2N2410-L2360

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Solid 750.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Solid 1000. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 750.

15PCJ2N2400-M2360

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Solid 1000. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 750.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 750.

15PCJ2N2380

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 750.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000.

15PCJ2M1410

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 750.

15PCJ2N1410-N1380

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 750.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 750.

15PCJ2N1380

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 750.

Frequently Asked Questions

What cable insulation diameter range does this joint support?

The joint supports cable insulation diameters between 1.900 and 2.120 inches.

What conductor size is compatible with this joint?

This joint is designed for 1250 kcmil compressed stranded conductors.

Does this joint include a sealing mechanism?

Yes, it includes a cold shrinkable jacket seal for moisture resistance.

What is the voltage rating of this cable joint?

The joint is rated for 35kV applications.

What material is the compression lug made of?

The compression lug is made of aluminum.

How to Install the 35PCJ1Q1440-S Straight Joint

This guide provides step-by-step instructions for the permanent installation of the 35PCJ1Q1440-S straight joint, designed for fully shielded, fully submersible connections of aluminum and/or copper conductor, wire shielded cables.

Estimated time: 1h 30m

Tools needed:

Cable stripping tool, Tapering tool, Wire brush, Crimping tool, Cleaning cloths

Supplies needed:

Joint Housing, Splice (Conductor Contact), Lubricant (DO NOT SUBSTITUTE), Grounding wire connector, #14 AWG copper wire (if needed), Cable jacket restoration kit (if applicable)

  1. Prepare Cables for Jointing

    Begin by ensuring all apparatus is de-energized to prevent serious injury. Overlap both cables and cut to 12 inches (305mm) from the joint's center line. Where applicable, remove the cable jacket of Cable 1 to 34 inches (865mm) and Cable 2 to 20 inches (510mm). Fold back the shield wires. Finally, cut both cables at the center line of the joint. Ensure all components are checked for damage and compatibility before proceeding.

  2. Prepare Cable 1 and Store Housing

    Taper the edge of Cable 1 from 1/2 inch to 1-1/2 inches (13mm to 38mm). Clean and then lubricate the insulation shield of Cable 1. Lubricate the inside bore of the joint housing on both ends. Carefully slide the housing onto Cable 1, pushing it up to the shield wires. This procedure is designed to prevent contamination of electrical interfaces.

  3. Prepare Cables for Splice Installation

    Using a stripping guide, carefully remove the cable insulation and then the insulation shield from both cables. Exercise extreme caution to AVOID CUTTING OR NICKING THE CABLE INSULATION OR CONDUCTOR, as this could lead to a failure of the assembly. Maintain cleanliness throughout this procedure.

  4. Install the Splice

    If using aluminum conductors, wirebrush them thoroughly and immediately insert them into the splice. Verify that the 'Check' dimension does not exceed 5 inches (127mm); if it does, redo the assembly. Crimp the splice following its provided recommendations. Wipe off any excess inhibitor. Check the distance between cable insulations; if it exceeds 5-1/4 inches (133mm), redo the assembly. Remove any sharp protrusions or metal chips generated during crimping from the splice and joint area. Clean cables as indicated, then lubricate to create a build-up at the insulation shield's edge.

  5. Complete Joint Assembly

    Slide the housing into its final position. Confirm proper positioning by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield. Reshape the shield wires and secure them to the ends of the joint as shown in the diagrams. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye, and repeat for Cable 2. If shield wires are smaller than #14 AWG, use a separate #14 AWG copper wire or equivalent. Connect all joint grounding wires and remaining shield wires using an appropriate connector. Reconstruct the cable jacket (if applicable) over both cables and the joint housing.

  6. Seal Cable Jacket (If Applicable)

    WARNING: If one or both of the cables being joined are jacketed, it is critically important to seal the ends of the jacket or completely restore the jacket across the joint. Follow standard operating procedures or instructions provided with compatible jacket sealing or restoration kits to ensure appropriate jacket seals or restoration, preventing moisture ingress and ensuring long-term integrity.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.