
ABB Installation Products 35PCJ1Q1440 35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…
UPC: 783786499526
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 35kV rated power cable joint for high-voltage applications
- Single-piece housing for simplified installation and reduced failure points
- Accommodates cable insulation diameters from 1.900 to 2.120 inches
- Aluminum conductor rated at 1250 AWG stranded for high-current capacity
- Designed for compatibility with industrial and utility power distribution systems
Specifications
Application | For Direct Burial, Vault, Submersible and Other Severe Service Applications |
Color | Black |
Conductor Range | 1250 kcmil |
Connection | Compression |
Insulation | Yes |
Material | EPDM Rubber |
Number Of Conductors | 2 |
Size | 15-3/4 inch long |
Special Features | Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable |
Standard | IEEE Standard 404 |
Type | Power Cable Joint |
Voltage Rating | 35 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 3.2500 L |
Package Weight (Metric) | 1.4740 kg |

35PCJ1Q1440-S
35kV Power Cable Joint Style 1, Cable Insulation Diameter 1.900 inch to 2.120 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1250. Cold Shrinkable Jacket Seal included.
35PCJ1Q2400
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.900 inch to 2.120 inch. Copper Conductor. Conductor Size AWG Solid 1000.
35PCJ2J1230
35kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
35PCJ1Q2380
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.900 inch to 2.120 inch. Copper Conductor. Conductor Size AWG Stranded 750.
15PCJ2N2410-M2400-TL
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 1000. With Sheild Adapter.
15PCJ2N2410-L2360
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Solid 750.
15PCJ2N2400-M2360
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Solid 1000. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 750.
15PCJ2N2380
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 750.Frequently Asked Questions
What voltage rating does this cable joint support?
This cable joint is rated for 35kV applications.
What is the conductor size for this joint?
The joint supports a 1250 AWG stranded aluminum conductor.
What insulation diameter range does this joint accommodate?
The joint is designed for cable insulation diameters between 1.900 and 2.120 inches.
Is this joint compatible with aluminum conductors?
Yes, this joint is specifically designed for aluminum conductors.
What type of housing does this joint use?
This joint features a single-piece housing for simplified installation.
How to Install the 15/25/35PCJ1 Series Cable Joint
This guide provides detailed instructions for the permanent, fully shielded, and submersible installation of the 15/25/35PCJ1 series straight joint for aluminum or copper conductor wire shielded cables.
Estimated time: 2h
Tools needed:
Wire strippers, Utility knife, Wire brush, Crimping tool (for splice), T&B WT3D tool (for 35kV installations, if applicable), Connector crimping tool (for grounding wires)
Supplies needed:
Joint Housing, Splice (Conductor Contact), Lubricant (DO NOT SUBSTITUTE), Conductor connector (user supplied), Grounding wire (e.g., #14 AWG copper, if shield wires are smaller than #14 AWG), DELTECt Cable ties (for 35kV installations), Cable jacket reconstruction material (if applicable)
- Ensure Safety and Inspect Components
DANGER: De-energize all apparatus before beginning installation. Ensure the work area is safe and free from energized products. This product must be installed by competent personnel trained in high voltage electrical equipment safety practices. Inspect all package contents for completeness and damage. Verify all components fit properly with the cable and mating products. Have all required tools ready and maintain cleanliness throughout the procedure.
- Prepare Cables for Joint Centerline
Overlap both cables and cut them to 12 inches (305mm) from the joint's centerline. This ensures sufficient length for shield wires to rejoin over the joint. Remove the cable jacket of Cable 1 to 37 inches (940mm) and Cable 2 to 21 inches (530mm). Fold back the shield wires. Cut both cables precisely at the joint's centerline.
- Taper Cable 1 and Position Housing
Taper the edge of Cable 1's insulation shield from 1/2 inch to 1-1/2 inches (13mm to 38mm). Clean and lubricate the insulation shield. Lubricate the inside bore of the joint housing on both ends. Slide the housing onto Cable 1, pushing it up to the shield wires for temporary storage.
- Remove Cable Insulation and Shield
Carefully remove the cable insulation and then the insulation shield from both cables. Exercise extreme caution to avoid cutting or nicking the cable insulation or conductor, as this can lead to product failure.
- Install and Crimp Conductor Splice
If conductors are aluminum, wire-brush them thoroughly and immediately insert them into the splice. Crimp the splice according to the recommendations provided with it. Wipe off any excess inhibitor from the splice. Remove any sharp protrusions or burrs generated during crimping, ensuring all metal chips and filings are cleared from the splice and joint assembly area.
- Clean and Lubricate Cables
Clean the cables where indicated. Lubricate the cables in the direction of the arrows to create a build-up or ramp of lubricant at the edge of the insulation shield, facilitating smooth housing installation.
- Slide Housing into Final Position
Slide the joint housing into its final position. Ensure proper positioning is achieved by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield.
- Install DELTECt Cable Ties (35kV Only)
For 35kV installations ONLY: Install two DELTECt Cable ties on each end of the cable entrance. Position the outer ties approximately 1/4 inch (6mm) from the splice edge, then install the second ties approximately 1/4 inch (6mm) from the first, with an offset of the locking heads. Use a T&B WT3D tool (not included) to tighten and trim the ties. Remove and discard the yellow pin from the joint grounding eye.
- Retrain and Connect Shield Wires
Retrain the shield wires and secure them to the ends of the joint as shown in the diagrams. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye. Repeat this for Cable 2. If shield wires are smaller than #14 AWG, use a separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and the remaining shield wires using an appropriate connector.
- Reconstruct Cable Jacket
Reconstruct the cable jacket (if applicable) over both cables and the joint housing to complete the installation and provide environmental protection.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.