ABB Installation Products 35PCJ1Q2380 35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…
UPC: 783786464876
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 35kV Power Cable Joint, Style 1
- Single-piece housing for simplified installation
- Cable Insulation Diameter: 1.900" - 2.120"
- Compatible with 750 AWG Stranded Copper Conductor
- ABB Installation Products
Specifications
Application | For Direct Burial, Vault, Submersible and Other Severe Service Applications |
Color | Black |
Conductor Range | 750 kcmil |
Connection | Compression |
Insulation | Yes |
Material | Copper |
Material | EPDM Rubber |
Number Of Conductors | 2 |
Series | 35PCJ1Q |
Size | 15-3/4 inch long |
Size | 1.900 inch to 2.120 inch |
Special Features | Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable |
Standard | IEEE Standard 404 |
Type | Power Cable Joint |
Voltage Rating | 35 kV |
Package Dimensions (L x W x H) | 15.5 IN x 4.75 IN x 3.19 IN |
Package Dimensions (L x W x H) | 39.37 cm x 12.065 cm x 8.1026 cm |
Package Weight (Imperial) | 3.2500 L |
Package Weight (Metric) | 1.4740 kg |

35PCJ1N1380-S
35kV Power Cable Joint Style 1, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. Cold Shrinkable Jacket Seal included.
35PCJ1Q1440-S
35kV Power Cable Joint Style 1, Cable Insulation Diameter 1.900 inch to 2.120 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 1250. Cold Shrinkable Jacket Seal included.
15PCJ2N2410-M2400-TL
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 1000. With Sheild Adapter.
15PCJ2N2410-L2360
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Solid 750.
15PCJ2N2400-M2360
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Solid 1000. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 750.
15PCJ2N2380
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 750.
15PCJ2M1410
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000.
15PCJ2N1410-N1380
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 750.Frequently Asked Questions
What is the 35 kV class DC withstand voltage during installation?
For a 35 kV class joint, the DC withstand voltage during installation is 100 kV.
What are the available voltage classes for PCJ joints?
Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.
What types of cables are compatible with PCJ joints?
PCJ joints are compatible with copper or aluminum conductors up to 1250 kcmil. They are designed for UD cable with concentric neutral and extruded insulation shielding.
Can PCJ joints be used for transition splicing?
Yes, Style 2 PCJ joints include separate cable adapters that allow for transition splicing between two different cable sizes.
What environments are suitable for installing PCJ power cable joints?
PCJ power cable joints can be installed in direct-burial, underground vault, and even overhead applications. They provide a fully submersible splice.
What is the maximum conductor size supported by PCJ joints?
Elastimold PCJ power cable joints can be used with conductors up to 1250 kcmil.
What is the continuous current rating of PCJ power cable joints?
The continuous current rating of PCJ power cable joints is equal to that of the cable rating.
What is the short-time current rating for PCJ joints?
The short-time current rating for PCJ power cable joints is equal to that of the cable rating, up to 35 kA.
What standards do the PCJ joint's shield and connectors meet?
The shield design meets IEEE 592 standard, and the connectors meet ANSI 119.4 Class A and Class 3 ratings.
What type of connector is included for aluminum conductors?
Kits for aluminum conductors include an aluminum compression connector suitable for splicing aluminum-to-aluminum or aluminum-to-copper conductors.
How to Install the 35PCJ1Q2380 Straight Joint
This guide provides step-by-step instructions for the permanent installation of the 35PCJ1Q2380 straight joint, designed for wire shielded cables, ensuring proper conductor splicing and housing assembly for high voltage applications.
Estimated time: 2h
Tools needed:
Cable cutting tool, Measuring tape, Cable jacket stripping tool, Cable insulation stripping tool, Wire brush, Crimping tool, T&B WT3D tool (for 35kV installations), Wire strippers
Supplies needed:
Joint Housing (included in kit), Splice (Conductor Contact) (included in kit), Lubricant (included in kit), Cleaning supplies, DELTECt Cable ties TYD5135 (for 35kV installations, user supplied), #14 AWG copper wire or equivalent (user supplied, if needed), Appropriate connector for grounding wires (user supplied)
- Prepare for Installation and Ensure Safety
Before beginning, ensure all apparatus are de-energized to prevent serious injury or fatality. Inspect all components for damage, proper rating, and compatibility with mating parts. Read the entire installation instructions thoroughly, gather all required tools, and maintain a clean work area throughout the procedure. Verify package contents are complete and undamaged.
- Prepare Cables for Joint Assembly
Overlap both cables and cut them to 12 inches (305mm) from the joint's centerline. Where applicable, remove the cable jacket of Cable 1 to 37 inches (940mm) and Cable 2 to 21 inches (530mm). Fold back the shield wires. Then, cut both cables precisely at the joint's centerline. Taper the edge of Cable 1's insulation shield at least 1/2 inch (13mm) to no greater than 1-1/2 inches (38mm). Clean and lubricate the insulation shield of Cable 1, and lubricate the inside bore of the joint housing on both ends. Slide the joint housing onto Cable 1, positioning it up to the shield wires.
- Remove Insulation and Prepare for Splice
Carefully remove the cable insulation from both Cable 1 and Cable 2 according to the 'Y' dimension in the provided table (e.g., 2 1/2 inches for 500-750 MCM). Then, carefully remove the insulation shield from both cables according to the 'X' dimension (e.g., 6 1/4 inches for 500-750 MCM). Exercise extreme caution to avoid cutting or nicking the cable insulation or conductor during this process.
- Install and Crimp the Splice
If the conductors are aluminum, wire-brush them thoroughly and immediately insert them into the splice. Check the dimension against the 'Max Check Before' table (e.g., 6 inches for 500-750 MCM); if it exceeds this, redo the assembly. Crimp the splice according to the manufacturer's recommendations provided with the splice. Wipe off any excess inhibitor. After crimping, check the distance between the cable insulations against the 'Max Check After' table (e.g., 6 1/4 inches for 500-750 MCM); if it exceeds this, redo the assembly. Remove any sharp protrusions or burrs generated during crimping, and ensure all metal chips or filings are removed from the splice and joint assembly area before proceeding.
- Lubricate and Complete Joint Assembly
Clean the cables where indicated and lubricate them in the direction of the arrows to create a build-up or ramp of lubricant at the edge of the insulation shield. Slide the joint housing into its final position, ensuring proper placement by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield. For 35kV installations only, install two DELTECt Cable ties on each end of the cable entrance, approximately 1/4 inch (6mm) from the edge of the splice, and the second tie approximately 1/4 inch (6mm) from the first with an offset of the locking heads. Use the T&B WT3D tool to tighten and trim the ties. Also for 35kV, remove and discard the yellow pin from the joint grounding eye. Retrain the shield wires and secure them to the ends of the joint as shown in the diagram. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye, and repeat for Cable 2. If shield wires are smaller than #14 AWG, use a separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and the remaining shield wires using an appropriate connector. Finally, reconstruct the cable jacket (where applicable) over both cables and the joint housing.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.