ABB Installation Products 15PCJ2N2380 15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable…
UPC: 783786473557
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15kV rated power cable joint for medium-voltage systems
- Universal housing with separate cable adapters for flexible sizing
- Supports copper conductors with insulation diameters 1.515–1.780 inch
- Compatible with 750 AWG stranded copper conductors
- Designed for reliable, weatherproof termination in industrial and utility applications
Specifications
Application | For Direct Burial, Vault, Submersible and Other Severe Service Applications |
Color | Black |
Conductor Range | 750 kcmil |
Connection | Compression |
Insulation | Yes |
Material | EPDM Rubber |
Number Of Conductors | 2 |
Size | 21 inch long |
Special Features | Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other severe service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable |
Standard | IEEE Standard 404 |
Type | Power Cable Joint |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 3.2500 L |
Package Weight (Metric) | 1.4740 kg |

15PCJ2N1410-N1380
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 750.
15PCJ2M1410
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000.
15PCJ2N1380
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 750.
15PCJ2N1410-M1360
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Solid 750.
15PCJ2H1240-F1240
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
15PCJ2H1270-F1220
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.
15PCJ2G1280
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 250.
15PCJ2H124P-F122P
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. With Customer Specific ModificationsFrequently Asked Questions
What voltage rating does this cable joint support?
The ABB 15PCJ2N2380 is rated for 15kV medium-voltage applications.
What cable insulation diameter range does this joint accommodate?
The joint supports cable insulation diameters from 1.515 inch to 1.780 inch.
What type of conductor is compatible with this joint?
This joint is designed for stranded copper conductors.
What AWG size conductor does this joint support?
The joint supports 750 AWG stranded copper conductors.
Is this joint suitable for outdoor installations?
The joint features a universal housing designed to provide weatherproof protection in outdoor environments.
How to Install the 15/25/35PCJ2WXXXX-RC Straight Joint
This guide provides step-by-step instructions for the permanent, fully shielded, and submersible installation of the 15/25/35PCJ2WXXXX-RC straight joint for aluminum and/or copper conductor, wire shielded cables.
Estimated time: 1h 30m
Tools needed:
Hex wrench, Wirebrush, Circular cutting tool, Crimping tool
Supplies needed:
Electrical Tape, Appropriate connector (for grounding wires), Bonding cable(s) (if required), Insulating tapes (if required), Sealing tapes (if required), Solder (if required), #14 AWG copper wire (if shield wires are smaller than #14 AWG), Heat/cold shrink material (for cable jacket reconstruction)
- Perform Initial Checks and Safety Precautions
Before starting, ensure all apparatus are de-energized. Inspect all components for damage, proper rating, and compatibility with cables. Verify the package contents are complete. Read all instructions and have tools ready. Examine the mating cable ends, ensuring both are free from moisture and other contaminants. This product must be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment.
- Prepare Cable Jackets and Shield Wires
Using the stripping guide, carefully remove the cable jacket of both cables for a distance of 11-1/4” (285.7mm). Remove any graphite coatings using a circular cutting tool or by scraping with glass 12” (30.5cm) beyond the cable jacket cut, avoiding sanding. Fold back the shield wires and tape the end of the wires on Cable 1 to the jacket, allowing enough extra length to rejoin later. Clean the surface of the insulation shield, shield wires, and jacket for a distance of 30” (760mm). Slide the joint housing onto Cable 1 to a distance of 30” (760mm). Lubricate the 11-1/4” (285.7mm) section of the cable.
- Prepare Cable Insulation and Apply Lubricant
Using the stripping guide, carefully remove the insulation shield and cable insulation. DO NOT CUT OR NICK THE INSULATION, as this could lead to assembly failure. Wrap two turns of tape 1” (25mm) from the edge of the insulation shield as a marker on both cables. Clean the cable insulation, then lubricate it to create a build-up or ramp of lubricant at the edge of the insulation shield.
- Install Cable Adapters
Take one cable adapter and lubricate the inside of both ends. Install the cable adapter onto Cable 1 until it meets the tape marker. Repeat this process for the other cable adapter on Cable 2.
- Install Retaining Collars
Select a retaining collar and partially thread the proper size setscrews (refer to instructions packaged with the collars). Position the retaining collar over the insulation, flush against the cable adapter. Using the supplied hex wrench, tighten each set screw one or two turns at a time to keep the collar centered over the insulation. Continue tightening until the set screws are below the surface of the collar. Repeat for Cable 2.
- Splice Conductors and Check Dimensions
Thoroughly clean the ends of the cable adapters and the cable as shown in the diagram. Install a hose clamp around the adapter on the opposite side of the splice from where the housing is stored to hold the adapter in place during final assembly. Tape over the hose clamp to form a smooth surface. Wirebrush the exposed conductors of both cables and immediately insert them into the splice. Ensure the 'Check' dimension does not exceed 8-1/2” (215mm); if it does, redo the assembly. Crimp the splice following its specific recommendations. Wipe off all excess inhibitor. Check the distance between cable adapters; if it exceeds 8-3/4” (222mm), redo the assembly. Clean and lubricate the outside surface of the cable adapters before sliding the housing into its final position.
- Complete Joint Assembly and Reconstruct Jacket
Slide the joint housing into its final position, centering it over the cable adapters. Remove all tape, ensuring that cable and adapter insulation are not exposed after positioning the joint. Reshape the shield wires and secure them to the ends of the joint. Insert one of the shield wires from Cable 1 (if #14 AWG or larger) through the joint grounding eye; repeat for Cable 2. If shield wires are smaller than #14 AWG, use separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and remaining shield wires using an appropriate connector. Reconstruct the cable jacket (where applicable) over both cables and over the joint housing using heat or cold shrink material (not included in the kit).
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.