
ABB Installation Products 15PCJ2N1380 15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable…
UPC: 783786447428
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15kV rated power cable joint
- Style 2 with universal housing
- Includes separate cable adapters
- Accommodates 1.515" to 1.780" insulation diameter
- Designed for AWG 750 stranded aluminum conductors
Specifications
Application | For Direct Burial, Vault, Submersible and Other Severe Service Applications |
Color | Black |
Conductor Range | 750 kcmil |
Connection | Compression |
Insulation | Yes |
Material | Aluminum |
Material | EPDM Rubber |
Number Of Conductors | 2 |
Series | 15PCJ2N |
Size | 21 inch long |
Size | 1.515 inch to 1.780 inch |
Special Features | Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable |
Standard | IEEE Standard 404 |
Type | Power Cable Joint |
Voltage Rating | 15 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 3.2500 L |
Package Weight (Metric) | 1.4740 kg |

15PCJ2N2410-L2360
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Solid 750.
15PCJ2N1410-M1360
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Solid 750.
15PCJ2H1240-F1240
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
15PCJ2H1270-F1220
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.
15PCJ2G1280
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 250.
15PCJ2H124P-F122P
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. With Customer Specific Modifications
15PCJ2G1270-F1210
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #3/Solid #2.
15PCJ2G1270-F1220
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.Frequently Asked Questions
What is the insulation diameter range for this cable joint?
The ABB 15kV Power Cable Joint Style 2 is designed to accommodate cable insulation diameters ranging from 1.515 inches to 1.780 inches.
What conductor type and size is this joint compatible with?
This joint is designed for stranded aluminum conductors, specifically supporting AWG 750 conductor sizes.
What is the voltage rating of this ABB cable joint?
The ABB 15kV Power Cable Joint Style 2 is rated for 15kV applications.
Does this cable joint come with separate adapters?
Yes, this ABB 15kV Power Cable Joint Style 2 includes separate cable adapters for installation.
How to Install the 15/25/35PCJ2WXXXX-RC Straight Joint for Wire Shielded Cables
This guide provides step-by-step instructions for installing the 15/25/35PCJ2WXXXX-RC straight joint, a permanent, fully shielded, and submersible joint for aluminum and/or copper conductor, wire shielded cables. It covers cable preparation, component assembly, and final joint completion.
Estimated time: 2h 30m
Tools needed:
Wire strippers, Circular cutting tool or glass scraper, Wirebrush, Hex wrench, Crimping tool, Electrical tape, Heat gun (if using heat shrink tubing)
Supplies needed:
Joint Housing (from kit), Splice (Conductor Contact, from kit), Cable Adapters (from kit), Lubricant (from kit), Retaining Collars (2, from kit), Hose Clamp (from kit), Appropriate electrical connector (for grounding, user supplied), #14 AWG copper wire or equivalent (if shield wires are smaller), Heat or cold shrink tubing (for jacket reconstruction, user supplied), Bonding cable(s), insulating/sealing tapes, solder, CNW’s connectors (if needed)
- Ensure Safety and Inspect Components
DANGER: All apparatus must be de-energized during installation or removal of parts. Install and operate in accordance with individual user, local, and national work rules. Inspect all parts for damage, rating, and compatibility with mating parts. This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment. Failure to follow these instructions will result in damage to the product and serious or fatal injury. Check package contents against the component list to ensure completeness and no damage. Verify all components fit properly with the cable and/or mating products. Read all instructions before starting and ensure all required tools are at hand, maintaining cleanliness throughout the procedure.
- Prepare Cable Ends
Examine the mating cable ends; both cables should be free from moisture and other contaminants. Remove any graphite coatings by circular cutting tool or scraping with glass 12 inches (30.5cm) beyond the cable jacket cut. Avoid sanding, as it may embed conductive particles within the cable jacket's insulation. If strand-filled or water-blocking material is present, contact the cable manufacturer for their procedures on welding and/or crimping the conductor.
- Remove Cable Jacket and Clean Cable 1
Using the stripping guide, carefully remove the cable jacket (if applicable) of both cables for a distance of 11-1/4 inches (285.7mm). Fold back the shield wires and tape the end of the wires on Cable 1 to the jacket, allowing enough extra length to rejoin over the joint later. Clean the surface of the insulation shield, shield wires, and jacket for a distance of 30 inches (760mm).
- Slide Joint Housing onto Cable 1
Slide the joint housing onto Cable 1 to a distance of 30 inches (760mm). Lubricate the cable for 11-1/4 inches (285.7mm) where the joint housing will eventually sit.
- Remove Insulation Shield and Cable Insulation
Using the stripping guide, carefully remove the insulation shield and cable insulation from both cables. DO NOT CUT OR NICK THE INSULATION, as this could result in failure of the assembly.
- Mark Cable Insulation with Tape
Wrap two turns of electrical tape 1 inch (25mm) from the edge of the insulation shield on both cables to serve as a marker.
- Clean and Lubricate Cable Insulation
Clean the cable insulation thoroughly. Then, lubricate the cable insulation to provide a build-up or ramp of lubricant at the edge of the insulation shield.
- Install Cable Adapters
Take one cable adapter and lubricate the inside of both ends. Install this cable adapter onto Cable 1 until it meets the tape marker. Repeat this process for the other cable adapter on Cable 2.
- Install Retaining Collars
Select a retaining collar and partially thread the proper size setscrews into it (refer to instructions packaged with the collars). Position the retaining collar over the insulation and flush against the cable adapter. Using the supplied hex wrench, tighten each set screw only one or two turns at a time to keep the collar centered over the insulation. Continue to tighten the set screws until they are below the surface of the collar. Repeat this process for Cable 2.
- Clean Adapters and Install Hose Clamp
Thoroughly clean the end of the cable adapters and the cable where shown in the diagram. Install a hose clamp around the adapter on the opposite side of the splice from where the housing is stored; this will hold the adapter in place during final assembly. Tape over the hose clamp to form a smooth surface.
- Prepare and Insert Conductors into Splice
Wirebrush the exposed conductors of both cables to ensure good contact. Immediately insert the prepared conductors into the splice. Verify that the 'Check' dimension (distance between cable adapters) does not exceed 8-1/2 inches (215mm); if it does, redo the assembly.
- Crimp the Splice
Crimp the splice securely, following the recommendations provided with the splice component. Ensure a proper and reliable connection.
- Clean and Verify Splice Dimensions
Wipe off all excess inhibitor from the splice area. Recheck the distance between the cable adapters. If it exceeds 8-3/4 inches (222mm), the assembly must be redone to ensure proper fit and function.
- Clean and Lubricate Cable Adapters
Clean and lubricate the outside surface of both cable adapters thoroughly before sliding the joint housing into its final position.
- Position Joint Housing
Slide the joint housing into its final position, carefully centering it over the cable adapters.
- Remove Tape and Verify Insulation Coverage
Remove all temporary tape used for marking or securing. Ensure that no cable or adapter insulation is exposed after the joint housing is correctly positioned.
- Secure Shield Wires
Reshape the shield wires and secure them to the ends of the joint housing as shown in the documentation diagrams.
- Connect Grounding Wires
Insert one of the shield wires from Cable 1 (if it is #14 AWG or larger) through the joint grounding eye. Repeat this for Cable 2. If the shield wires are smaller than #14 AWG, use a separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and any remaining shield wires using an appropriate electrical connector.
- Reconstruct Cable Jacket
Reconstruct the cable jacket (where applicable) over both cables and also over the joint housing. This typically involves using heat or cold shrink tubing (materials for this step are not included in the kit and must be user-supplied).
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.