Authorized ABB Distributor (Installation Products)
ABB - Installation Products 35PCJ1P1400-S - 35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.725 inch to 1.935 inch. Aluminum Conductor. Conductor Size AWG Solid 1000. Cold-Shrinkable Jacket Seal Included.

ABB Installation Products 35PCJ1P1400-S 35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…

UPC: 075114141826


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 35PCJ1P1400-S is a 35kV power cable joint designed for permanent, fully shielded, and fully submersible straight splices in industrial power distribution systems. This Style 1 joint accommodates cable insulation diameters from 1.725 inches to 1.935 inches and is optimized for aluminum conductors with a solid 1000 AWG size. The single-piece molded rubber housing integrates a conductive shield that meets IEEE Standard 592 for true deadfront construction, eliminating the need for additional taping at the cable entrance. The joint features a pin-and-socket interlock capable of withstanding axial pulls up to 500 lbs, making it suitable for direct burial or vault installations. Electrical ratings include a 200kV BIL impulse withstand, 69kV AC withstand, and 30kV AC corona extinction at 3pC sensitivity. The continuous current rating matches the connected cable, with a short-time current rating up to 35kA. A grounding eye is provided for connecting a ground wire to the molded conductive shield, ensuring safe operation. The cold-shrinkable jacket seal included in the kit provides waterproof integrity, while the design adheres to IEEE Standard 404 for 35kV applications. Typical uses include new cable installations or repairs to broken runs in existing systems, particularly where submersible or buried conditions are present. The joint is compatible with UD cables featuring concentric neutral and extruded insulation shielding, as well as fabric tape shielded or lead-jacketed cables when used with the appropriate Elastimold shield adapter or grounding device.
  • 35kV voltage rating with 200kV BIL impulse withstand per IEEE Standard 404
  • Single-piece molded rubber housing with conductive shield for deadfront construction
  • Accommodates cable insulation diameters from 1.725" to 1.935" and 1000 AWG solid aluminum conductors
  • Fully submersible and direct-burial capable with 500 lb pull resistance
  • Includes cold-shrinkable jacket seal for waterproof integrity and grounding eye for shield connection

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
1000 kcmil
Connection
Compression
Insulation
Yes
Material
Aluminum
Material
EPDM Rubber
Number Of Conductors
2
Series
Style 1
Size
15-3/4 inch long
Size
1000 AWG Solid
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.900 inch to 2.120 inch. Aluminum Conductor. Conductor Size AWG Solid 1000.

35PCJ1Q1400

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.900 inch to 2.120 inch. Aluminum Conductor. Conductor Size AWG Solid 1000.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.

15PCJ2G1240-F1220

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 4, Connector type Copper/no connector required, Connector Code 00P - Not Included, Heatsink Size N - Not Required, Heatsink Bore - N - Not Required. Type Shield - N - Unknown, Metallic Screen Continuity Kit - B - 4/0 Bonding Cable 6 foot Quantity 2 with 4 Split Bolts, Armor Kit - not specified, Outer Jacket Restoration Kit - not specified

69TCJS44DP0597633

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 4, Connector type Copper/no connector required, Connector Code 00P - Not Included, Heatsink Size N - Not Required, Heatsink Bore - N - Not Required. Type Shield - N - Unknown, Metallic Screen Continuity Kit - B - 4/0 Bonding Cable 6 foot Quantity 2 with 4 Split Bolts, Armor Kit - not specified, Outer Jacket Restoration Kit - not specified
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Copper Conductor. Conductor Size AWG Stranded 350.

15PCJ1G2300

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Copper Conductor. Conductor Size AWG Stranded 350.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0. Cold-Shrinkable Jacket Seal Included.

35PCJ1K1250-S

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0. Cold-Shrinkable Jacket Seal Included.
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 5, Connector type Copper/no connector required, Connector Code 00P - Not Included, Heatsink Size N - Not Required, Heatsink Bore - N - Not Required. Type Shield - N - Unknown, Metallic Screen Continuity Kit - B - 4/0 Bonding Cable 6 foot Quantity 2 with 4 Split Bolts, Armor Kit - not specified, Outer Jacket Restoration Kit - not specified, For Qatar

69TCJS45DP0597945-Q

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 4, Housing Size 5, Connector type Copper/no connector required, Connector Code 00P - Not Included, Heatsink Size N - Not Required, Heatsink Bore - N - Not Required. Type Shield - N - Unknown, Metallic Screen Continuity Kit - B - 4/0 Bonding Cable 6 foot Quantity 2 with 4 Split Bolts, Armor Kit - not specified, Outer Jacket Restoration Kit - not specified, For Qatar
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Solid 350. Cold-Shrinkable Jacket Seal Included.

35PCJ1L1290-S

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Solid 350. Cold-Shrinkable Jacket Seal Included.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Conductor. Conductor Size AWG Stranded 350.

15PCJ1H2300

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Conductor. Conductor Size AWG Stranded 350.

Frequently Asked Questions

What types of cable splicing do PCJ joints support?

PCJ power cable joints support straight splicing of two similar cables or transition splicing of different cable sizes, up to 1250 kcmil.

What safety standards do PCJ joints meet?

The shield design meets IEEE 592 standard, and the connectors meet ANSI 119.4 Class A and Class 3 ratings.

What connector type is needed for copper-to-copper splices?

An all-copper compression connector is required for copper-to-copper connections. Aluminum compression connectors are for aluminum-to-aluminum or aluminum-to-copper.

What is the maximum conductor size supported by PCJ joints?

PCJ joints support conductor sizes up to 1250 kcmil for both stranded/compressed and compressed/solid types.

What is the short-time current rating for PCJ joints?

The short-time current rating for PCJ power cable joints is equal to that of the cable rating, up to 35 kA.

What is the continuous current rating of PCJ power cable joints?

The continuous current rating of PCJ power cable joints is equal to that of the cable rating.

What pull force can the PCJ pin-and-socket interlock withstand?

The pin-and-socket interlock of the PCJ power cable joints can withstand a pull force of up to 500 lb.

What are the two styles of PCJ power cable joints?

Style 1 is for straight splicing of two similar cables. Style 2 includes separate cable adapters for transition splicing between two different cable sizes.

What conductor materials are compatible with PCJ joints?

PCJ power cable joints are compatible with both copper and aluminum conductors, supporting a wide range of sizes up to 1250 kcmil.

What voltage classes are available for PCJ joints?

Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

How to Install the 15/25/35PCJ1 Series Straight Cable Joint

This guide provides detailed instructions for installing the 15/25/35PCJ1 series straight joint, a permanent, fully shielded, and submersible solution for connecting wire-shielded cables. Ensure all safety precautions are followed for high-voltage electrical equipment.

Estimated time: 2h

Tools needed:

Wire-brush, Crimping tool (specific to splice), T&B WT3D tool (for 35kV DELTECt Cable ties, not included), Measuring tape or ruler, Cable stripping tools (for jacket, insulation, insulation shield)

Supplies needed:

Joint Housing (included), Splice (Conductor Contact) (included), Lubricant (DO NOT SUBSTITUTE) (included), Appropriate connector (for grounding wires/shield wires), DELTECt Cable ties TYD5135 (for 35kV ONLY), #14 AWG copper wire or equivalent (if shield wires are smaller than #14 AWG), Cleaning supplies, Inhibitor (implied)

  1. Prepare for Installation and Ensure Safety

    Before starting, ensure all apparatus is de-energized. Read the entire installation instructions and verify all package contents are complete and undamaged. Confirm all components fit properly with the cable and mating products. Gather all required tools and maintain a clean work area. This product must only be installed by competent personnel trained in high-voltage electrical safety practices.

  2. Prepare Cables and Store Joint Housing

    Overlap both cables and cut them to 12 inches (305mm) from the joint's centerline to ensure sufficient shield wire length. Where applicable, remove the cable jacket of Cable 1 to 37 inches (940mm) and Cable 2 to 21 inches (530mm). Fold back the shield wires. Cut both cables precisely at the joint's centerline. Taper the edge of Cable 1's insulation shield at least 1/2 inch (13mm) to no more than 1-1/2 inches (38mm). Clean and lubricate the insulation shield. Lubricate the inside bore of the joint housing on both ends, then slide the housing onto Cable 1 up to the shield wires.

  3. Remove Cable Insulation and Insulation Shield

    Carefully remove the cable insulation from both cables, followed by the insulation shield. Exercise extreme caution to avoid cutting or nicking the cable insulation or conductor. Refer to the provided table for precise 'X' and 'Y' dimensions based on conductor size (e.g., 500-750 MCM or 1000 MCM) to ensure correct removal lengths.

  4. Install and Crimp the Splice

    If conductors are aluminum, wire-brush them thoroughly and immediately insert them into the splice. Check the dimension against the 'Max Check Before' table; if it exceeds, redo the assembly. Crimp the splice according to its specific recommendations. Wipe off any excess inhibitor. Verify the distance between cable insulations against the 'Max Check After' table; if it exceeds, redo the assembly. Remove any sharp protrusions or burrs generated during crimping and ensure all metal chips/filings are cleared from the splice and joint assembly area. Clean the cables where indicated and lubricate in the direction of the arrows to create a lubricant build-up at the edge of the insulation shield.

  5. Complete Joint Assembly and Grounding

    Slide the joint housing into its final position, ensuring proper placement by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield. For 35kV applications ONLY: Install two DELTECt Cable ties (TYD5135) on each end of the cable entrance, approximately 1/4 inch (6mm) from the splice edge, with the second tie 1/4 inch (6mm) from the first and locking heads offset. Use a T&B WT3D tool (not included) to tighten and trim the ties. Remove and discard the yellow pin from the joint grounding eye. Retrain the shield wires and secure them to the ends of the joint. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye, and repeat for Cable 2. If shield wires are smaller than #14 AWG, use a separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and remaining shield wires using an appropriate connector. Finally, reconstruct the cable jacket (where applicable) over both cables and the joint housing.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.