Authorized ABB Distributor (Installation Products)
ABB - Installation Products 35PCJ1N2330 - 35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 500.

ABB Installation Products 35PCJ1N2330 35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…

UPC: 783786653737


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This ABB 35kV Power Cable Joint, SKU 35PCJ1N2330, is designed for reliable termination of single-conductor, 35kV power cables with copper conductors. It accommodates cable insulation diameters ranging from 1.515 inches to 1.780 inches, ensuring a secure fit for specified cable sizes. The joint features a single-piece housing construction, simplifying installation and reducing potential points of failure. Engineered for copper conductors of size 500 AWG stranded, this product is suitable for medium-voltage power distribution networks. The Style 1 designation indicates a specific configuration for this type of joint. ABB's Installation Products division manufactures this component, adhering to established industry standards for electrical connections. This joint is intended for use in power systems where robust and dependable cable terminations are essential for operational integrity and safety. Its design focuses on providing a well-insulated and mechanically sound connection for critical power infrastructure. The UNSPSC code 39121452 categorizes this product within electrical connectors and accessories.
  • 35kV voltage rating for medium-voltage applications.
  • Accommodates cable insulation diameter from 1.515" to 1.780".
  • Designed for 500 AWG stranded copper conductors.
  • Single-piece housing for simplified installation.
  • ABB Installation Products manufacturer.

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
500 kcmil
Connection
Compression
Insulation
Yes
Material
EPDM Rubber
Material
Copper, Poly
Number Of Conductors
2
Series
35PCJ1N
Size
15-3/4 inch long
Size
1.515-1.780 inch (insulation diameter)
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
35 kV
Package Dimensions (L x W x H)
15.5 IN x 4.75 IN x 3.62 IN
Package Dimensions (L x W x H)
39.37 cm x 12.065 cm x 9.1948 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Solid 500.

35PCJ1M1310

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Solid 500.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

35PCJ1K1240

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

25PCJ1K1240

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Conductor. Conductor Size AWG Solid 350.

25PCJ1K2290

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Conductor. Conductor Size AWG Solid 350.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

25PCJ1H2240

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

15PCJ1G1270

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Stranded 350.

35PCJ1M2300

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Stranded 350.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Stranded 500.

25PCJ1L2330

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Stranded 500.

Frequently Asked Questions

How do I order a transition joint with different cable sizes?

When constructing a catalog number for a transition joint, list the larger connector first and the smaller connector second.

What voltage classes are available for PCJ joints?

Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

What types of cables can PCJ joints splice?

PCJ joints can splice two similar cables (Style 1) or transition splice different cable sizes (Style 2) up to 1250 kcmil. They work with copper or aluminum conductors.

What conductor materials are compatible with PCJ joints?

PCJ power cable joints are compatible with both copper and aluminum conductors. Specific connectors are required for copper-to-copper connections.

Can copper connectors be used with aluminum conductors?

No, copper compression connectors should not be used on aluminum conductors. Aluminum compression connectors are suitable for aluminum-to-aluminum or aluminum-to-copper connections.

What is the maximum conductor size for PCJ joints?

Elastimold PCJ power cable joints can accommodate a wide range of conductor sizes up to 1250 kcmil.

What are the installation environments for PCJ joints?

PCJ power cable joints provide a permanent, fully shielded, fully submersible splice suitable for direct-burial, underground vault, and overhead applications.

What is the continuous current rating of PCJ joints?

The continuous current rating of PCJ power cable joints is equal to that of the cable rating.

What is the short-time current rating of PCJ joints?

The short-time current rating of PCJ power cable joints is equal to that of the cable rating, up to 35 kA.

What standards do PCJ joint shields and connectors meet?

The shield design meets IEEE 592 standard, and the connectors meet ANSI 119.4 Class A and Class 3 ratings.

How to Install the 15/25/35PCJ1 Series Straight Joint

This guide provides step-by-step instructions for the permanent, fully shielded, and submersible installation of the 15/25/35PCJ1 series straight joint for wire shielded cables. Ensure all safety precautions are followed for high voltage electrical equipment.

Estimated time: 2h

Tools needed:

Cable stripping tools, Utility knife or tapering tool, Wire-brush, Crimping tool, Measuring tape or ruler, T&B WT3D tool (recommended for 35kV cable ties)

Supplies needed:

Joint Housing, Splice (Conductor Contact), Lubricant (DO NOT SUBSTITUTE), Appropriate connector (for grounding wires), DELTECt Cable ties TYD5135 (for 35kV ONLY), #14 AWG copper wire or equivalent, Cleaning supplies, Inhibitor (for aluminum conductors)

  1. De-energize and Inspect Apparatus

    DANGER: Ensure all apparatus is de-energized during installation. Do not touch or move energized products. Verify all components are complete, undamaged, and compatible with the cable and mating products. This installation must be performed by competent personnel trained in high voltage electrical safety practices.

  2. Prepare Cables for Jointing

    Overlap both cables and cut them to 12 inches (305mm) from the joint centerline. Where applicable, remove the cable jacket of Cable 1 to 37 inches (940mm) and Cable 2 to 21 inches (530mm). Fold back the shield wires. Then, cut both cables at the joint centerline.

  3. Taper Cable 1 and Store Housing

    Taper the edge of Cable 1 insulation at least 1/2 inch (13mm) to no greater than 1-1/2 inches (38mm). Clean and lubricate the insulation shield of Cable 1. Lubricate the inside bore of the joint housing on both ends. Slide the joint housing onto Cable 1, pushing it up to the shield wires for temporary storage.

  4. Remove Cable Insulation and Shield

    Carefully remove the cable insulation and then the insulation shield from both Cable 1 and Cable 2 according to the specified 'X' and 'Y' dimensions for your conductor size. DO NOT CUT OR NICK THE CABLE INSULATION OR CONDUCTOR during this process.

  5. Install and Crimp Splice

    If conductors are aluminum, wire-brush them immediately before insertion into the splice. Insert the conductors into the splice and check the dimension against the 'Max Check Before' table. Crimp the splice following the manufacturer's recommendations. After crimping, wipe off any excess inhibitor and check the distance between cable insulations against the 'Max Check After' table. Remove any sharp protrusions or burrs from the crimped splice and the joint assembly area.

  6. Clean and Lubricate Cables for Housing

    Clean the cables where indicated in the diagram. Lubricate the cables in the direction of the arrows to create a build-up or ramp of lubricant at the edge of the insulation shield on both Cable 1 and Cable 2.

  7. Position Joint Housing

    Slide the joint housing into its final position over the splice. Ensure proper positioning by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield.

  8. Install 35kV Cable Ties (If Applicable)

    For 35kV installations ONLY: Install two DELTECt Cable ties on each end of the cable entrance. Position the outer ties approximately 1/4 inch (6mm) from the edge of the splice, then install the second ties approximately 1/4 inch (6mm) from the first, offsetting the locking heads. Use a T&B WT3D tool (recommended) to tighten and trim the ties. Remove and discard the yellow pin from the joint grounding eye.

  9. Connect Grounding Wires

    Retrain the shield wires and secure them to the ends of the joint as shown in the diagram. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye, and repeat for Cable 2. If shield wires are smaller than #14 AWG, use separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and the remaining shield wires using an appropriate connector.

  10. Reconstruct Cable Jacket

    Where applicable, reconstruct the cable jacket over both cables and the joint housing to complete the installation.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.