Authorized ABB Distributor (Installation Products)
ABB - Installation Products 35PCJ1N1330-S - 35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 500. Cold-Shrinkable Jacket Seal Included.

ABB Installation Products 35PCJ1N1330-S 35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…

UPC: 783786081530


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 35PCJ1N1330-S is a 35kV power cable joint designed for reliable medium-voltage cable connections. This joint accommodates aluminum conductors sized at 500 AWG stranded, with cable insulation diameters ranging from 1.515 to 1.780 inches. The single-piece housing simplifies installation while ensuring consistent performance in critical applications. The cold-shrinkable jacket seal included with this joint provides a watertight and corrosion-resistant termination, reducing the risk of moisture ingress and extending service life. This joint is engineered for use in medium-voltage distribution systems, including utility, industrial, and commercial installations where 35kV-rated cable joints are required. Key specifications: - Rated voltage: 35kV - Conductor type: Aluminum, 500 AWG stranded - Insulation diameter range: 1.515" to 1.780" - Housing style: Single-piece design - Included seal: Cold-shrinkable jacket This joint is part of ABB’s Installation Products line, known for durable and field-proven solutions in power distribution. The single-piece housing design minimizes installation steps, reducing labor time while maintaining electrical integrity. Ideal for underground and aerial cable systems requiring a 35kV-rated joint with reliable sealing and long-term performance.
  • 35kV-rated power cable joint for medium-voltage applications
  • Accommodates 500 AWG stranded aluminum conductors
  • Single-piece housing for simplified installation
  • Cable insulation diameter range: 1.515" to 1.780"
  • Includes cold-shrinkable jacket seal for watertight termination

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
500 kcmil
Conductor Size
500 AWG Stranded
Connection
Compression
Insulation
Yes
Material
Aluminum
Material
EPDM Rubber
Number Of Conductors
2
Series
Style 1
Size
15-3/4 inch long
Size
Cable Insulation Diameter - 1.515-1.780 inches
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Solid 500.

35PCJ1M1310

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Solid 500.
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size P Bore Diameter at Jacket/Insulation Transition 1.570. Connector Type - Copper, Connector Code 40P - Conductor Diameter Range - 1.036-1.100 inch (26.31-27.94mm), Heatsink Bore - N - 1.500 inch Diameter. Type Shield - D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink

69TCJS1P240PNDNNB

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size P Bore Diameter at Jacket/Insulation Transition 1.570. Connector Type - Copper, Connector Code 40P - Conductor Diameter Range - 1.036-1.100 inch (26.31-27.94mm), Heatsink Bore - N - 1.500 inch Diameter. Type Shield - D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size N Bore Diameter at Jacket/Insulation Transition 1.390. Connector Type - Copper, Connector Code 30P - Conductor Diameter Range - .636-.686 inch (16.15-17.42mm), Heatsink Size/Bore - E - .921 inch Diameter. Type Shield - B - Copper 1/3 Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - HeatShrink

69TCJS1N230PEBNNB

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size N Bore Diameter at Jacket/Insulation Transition 1.390. Connector Type - Copper, Connector Code 30P - Conductor Diameter Range - .636-.686 inch (16.15-17.42mm), Heatsink Size/Bore - E - .921 inch Diameter. Type Shield - B - Copper 1/3 Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - HeatShrink
69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 4, Housing Size 5, 4Q

69TCJN4-5-4Q

69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 4, Housing Size 5, 4Q
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750.

69TCJS1-Q-Q

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750.
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size P Bore Diameter at Jacket/Insulation Transition 1.570. Housing only

69TCJS1-P-Q

69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size P Bore Diameter at Jacket/Insulation Transition 1.570. Housing only
69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Copper, Connector Code 31P - Conductor Diameter Range - .687-.745 inch (17.45-18.92mm), Heatsink Size/Bore - Q - 1.625 inch Diameter. Type Shield - A - Copper Tape, Metallic Screen Continuity Kit - V - #2 Flat Braid 6 foot quantity 1, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - HeatShrink

69TCJN1Q231PQAVNB

69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Copper, Connector Code 31P - Conductor Diameter Range - .687-.745 inch (17.45-18.92mm), Heatsink Size/Bore - Q - 1.625 inch Diameter. Type Shield - A - Copper Tape, Metallic Screen Continuity Kit - V - #2 Flat Braid 6 foot quantity 1, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - HeatShrink
69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Aluminum, Connector Code 36P - Conductor Diameter Range - .901-.935 inch (22.88-23.75mm), Heatsink Size/Bore - N - 1.500 inch Diameter. Type Shield - D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - HeatShrink

69TCJN1Q136PNDNNB

69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Aluminum, Connector Code 36P - Conductor Diameter Range - .901-.935 inch (22.88-23.75mm), Heatsink Size/Bore - N - 1.500 inch Diameter. Type Shield - D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - HeatShrink

Frequently Asked Questions

How are catalog numbers constructed for transition joints?

When constructing a catalog number for a transition joint (two different-size cables), list the larger connector first and the smaller connector second.

Can copper compression connectors be used with aluminum conductors?

No, copper compression connectors are suitable for splicing copper conductors to copper conductors only and should not be used on aluminum conductors.

What is the cable insulation diameter range for 35PCJ-1/2?

For 35PCJ-1 and 35PCJ-2, the cable insulation diameter ranges from 0.850 inches (Symbol H) to 2.120 inches (Symbol Q).

What is the 35 kV class DC withstand voltage during installation?

For the 35 kV class, the DC withstand during installation is 100 kV.

What safety standards do PCJ power cable joints meet?

The shield design meets IEEE 592 standard, and connectors meet ANSI 119.4 Class A and Class 3 ratings.

What is the short-time current rating of PCJ joints?

The short-time current rating is equal to that of the cable rating, up to 35 kA.

What is the continuous current rating of PCJ joints?

The continuous current rating of PCJ power cable joints is equal to that of the cable rating.

Where can PCJ power cable joints be installed?

These joints provide a permanent, fully shielded, fully submersible splice suitable for direct-burial, underground vault, and overhead applications.

What conductor types are compatible with PCJ joints?

PCJ power cable joints can be used with copper or aluminum conductors, accommodating a wide range of sizes up to 1250 kcmil.

What voltage classes are available for PCJ joints?

Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

How to Install the 15/25/35PCJ1 Series Cable Joint

This guide provides step-by-step instructions for the permanent, fully shielded, and submersible installation of the 15/25/35PCJ1 series straight joint for aluminum to aluminum and/or aluminum to copper conductor, wire shielded cables. Installation must be performed by competent personnel trained in high voltage safety.

Estimated time: 2h

Tools needed:

Wire strippers, Cutting tool, Wire brush, Crimping tool, T&B WT3D tool (recommended for 35kV cable ties)

Supplies needed:

Joint Housing, Splice (Conductor Contact), Lubricant (DO NOT SUBSTITUTE), Connector (User Supplied, for grounding wires), DELTECt Cable ties (TYD5135, for 35kV ONLY), #14 AWG copper wire or equivalent (if shield wires are smaller than #14 AWG), Cable jacket reconstruction material (where applicable)

  1. De-energize All Apparatus

    DANGER: Ensure all apparatus in the work area are completely de-energized during installation or removal of parts. Do not touch or move energized products. Failure to follow this instruction will result in serious or fatal injury.

  2. Inspect Package Contents and Components

    Check the contents of the package to ensure they are complete and undamaged. Inspect all components for proper fit with the cable and/or mating products. Read the entire installation instructions before starting.

  3. Gather Tools and Maintain Cleanliness

    Have all required tools at hand and maintain cleanliness throughout the entire installation procedure to prevent contamination of electrical interfaces.

  4. Prepare Cables for Joint Centerline

    Overlap both cables and cut them to 12 inches (305mm) from the intended centerline of the joint. This ensures sufficient length of shield wires to be rejoined over the completed joint.

  5. Remove Cable Jackets

    Where applicable, remove the cable jacket of Cable 1 to 37 inches (940mm) and the cable jacket of Cable 2 to 21 inches (530mm).

  6. Fold Back Shield Wires

    Carefully fold back the shield wires on both Cable 1 and Cable 2.

  7. Cut Cables at Centerline

    Cut both Cable 1 and Cable 2 precisely at the centerline of the joint.

  8. Taper Cable 1 Insulation

    Taper the edge of Cable 1 insulation at least 1/2 inch (13mm) to no greater than 1-1/2 inches (38mm).

  9. Clean and Lubricate Cable 1 Insulation Shield

    Clean and lubricate the insulation shield of Cable 1.

  10. Lubricate Joint Housing

    Lubricate the inside bore of the joint housing on both ends with the provided lubricant (DO NOT SUBSTITUTE).

  11. Store Housing on Cable 1

    Slide the joint housing onto Cable 1, positioning it up to the shield wires for temporary storage. This procedure will not contaminate electrical interfaces.

  12. Remove Cable Insulation

    Carefully remove the cable insulation from both Cable 1 and Cable 2 to the specified 'Y' dimension (refer to the document's table for 500-750 MCM or 1000 MCM conductors). DO NOT CUT OR NICK THE CABLE INSULATION OR CONDUCTOR.

  13. Remove Insulation Shield

    Carefully remove the insulation shield from both Cable 1 and Cable 2 to the specified 'X' dimension (refer to the document's table for 500-750 MCM or 1000 MCM conductors). DO NOT CUT OR NICK THE CABLE INSULATION.

  14. Prepare and Insert Conductors into Splice

    If conductors are aluminum, wire-brush them thoroughly and immediately insert them into the splice. Check the dimension to the 'Max Check Before' table (6 inches or 6 1/8 inches). If it exceeds this dimension, redo the assembly.

  15. Crimp the Splice

    Crimp the splice following the recommendations provided with the splice itself.

  16. Clean Splice Area

    Wipe off all excess inhibitor from the splice area where applicable. Check the distance between cable insulations against the 'Max Check After' table (6 1/4 inches or 6 1/2 inches). If it exceeds this dimension, redo the assembly.

  17. Remove Burrs and Clean Splice

    Remove any sharp protrusions or burrs that were generated when crimping the splice. Metal chips or filings must be thoroughly removed from the splice and joint assembly area prior to sliding the joint housing.

  18. Clean and Lubricate Cables for Housing

    Clean the cables where indicated in the diagram. Lubricate the cables in the direction of the arrows to provide a build-up or ramp of lubricant at the edge of the insulation shield.

  19. Slide Housing into Final Position

    Slide the joint housing into its final position. Proper positioning is ensured by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield.

  20. Install Cable Ties (35kV ONLY)

    For 35kV installations ONLY: Install two DELTECt Cable ties (TYD5135) on each end of the cable entrance. Begin by installing the outer ties approximately 1/4 inch (6mm) from the edge of the splice, then install the second ties approximately 1/4 inch (6mm) from the first with an offset of the locking heads. Use the T&B WT3D tool (not included) to tighten and trim the ties.

  21. Remove Grounding Pin (35kV ONLY)

    For 35kV installations ONLY: Remove the yellow pin from the joint grounding eye and discard it.

  22. Retrain and Secure Shield Wires

    Retrain the shield wires and secure them to the ends of the joint as shown in the diagram.

  23. Insert Shield Wires into Grounding Eye

    Insert one of the shield wires from Cable 1 (if #14 AWG or larger) through the joint grounding eye. Repeat this process for Cable 2. If shield wires are smaller than #14 AWG, use a separate #14 AWG copper wire or equivalent.

  24. Connect Grounding Wires

    Connect the joint grounding wires and the remaining shield wires using an appropriate user-supplied connector, as shown in the diagram.

  25. Reconstruct Cable Jacket

    Reconstruct the cable jacket (where applicable) over both cables and the joint housing to complete the installation.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.