
Contact for Pricing
Overview
- 69 kV Voltage Rating for high-power transmission
- Shieldbreak Housing Type for effective electrical stress management
- Housing Style 1 for optimized performance
- Size Q with 1.750" (44.45mm) Bore Diameter at jacket/insulation transition
- ABB - Installation Products manufacturer for trusted quality
Specifications
Application | For use on Solid Dielectric Cables - providing permanent, fully-shielded, fully submersible cable joints for direct burial or vault applications |
Color | Black |
Connection | Compression |
Insulation | Yes |
Material | EPDM Rubber |
Number Of Conductors | 2 |
Special Features | Each Cable Joint is produced exactly to design, producing a quality not possible with field molding equipment or tape. Electrically tested in the factory to ensure consistent quality. Molding is done in the factory, reducing on-site time - no penciling of cable installation required. Easy to learn installation procedure. Field molds, wrapping machines or pre-stretch not required, and a low-cost assembly tool is available. Extended shelf life enables instant availability of spares. Designed with optimized pre-molded stress control and heat transfer capabilities |
Standard | ANSI C119.4, Shield Test IEEE 592 |
Temperature Rating, Maximum | 194 F |
Temperature Rating, Maximum | 90 C |
Temperature Rating, Minimum | 194 F |
Temperature Rating, Minimum | 90 C |
Type | Transmission Cable Joint - Shieldbreak |
Voltage Rating | 69 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

69TCJS4-5-4
69 kV, TCJ - Transmission Cable Joint. Housing Type - Shieldbreak. Housing Style 4. Housing Size 5.
69TCJS1-P-Q
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size P Bore Diameter at Jacket/Insulation Transition 1.570. Housing only
69TCJN1Q231PQAVNB
69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Copper, Connector Code 31P - Conductor Diameter Range - .687-.745 inch (17.45-18.92mm), Heatsink Size/Bore - Q - 1.625 inch Diameter. Type Shield - A - Copper Tape, Metallic Screen Continuity Kit - V - #2 Flat Braid 6 foot quantity 1, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - HeatShrink
69TCJN1Q136PNDNNB
69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750. Connector Type - Aluminum, Connector Code 36P - Conductor Diameter Range - .901-.935 inch (22.88-23.75mm), Heatsink Size/Bore - N - 1.500 inch Diameter. Type Shield - D - Copper Tape and Neutral Wire, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - HeatShrink
69TCJN1Q
69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 1, Housing Only, Housing Size Q Bore Diameter at Jacket/Insulation Transition 1.750.
69TCJN43246P3LABNN
69 kv, Transmission Cable Joint, Housing Type - Non-Shieldbreak, Housing Style 4, Housing Size 3, Connector type Copper, Connector Code 46P - Conductor Diameter Range - 1.328-1.377 inch (33.73-34.98mm), Heatsink Size 3 - Outside Diameter 2.250 inch ( 57.15mm), Heatsink Bore - L - 1.406 inch Diameter. Type Shield - A - Copper Tape, Metallic Screen Continuity Kit - B -4/0 Bonding Cable 6 foot quantity 2 with Split Bolts quantity 4, Armor Kit - N - not required, Outer Jacket Restoration Kit - N - not required
69TCJS1PB40PNLNNB
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size P Bore Diameter at Jacket/Insulation Transition 1.570. Connector Type - Copper/no connector required, Connector Code 40P - Conductor Diameter Range - 1.036-1.100 inch (26.31-27.94mm), Heatsink Bore - N - 1.500 inch Diameter.. Type Shield - L - Lead and Neutral Wires, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not required, Outer Jacket Restoration Kit - B - Heat Shrink
69TCJS1NB38PNNNN
69 kv, Transmission Cable Joint, Housing Type - Shieldbreak, Housing Style 1, Housing Size N Bore Diameter at Jacket/Insulation Transition 1.390. Connector Type - Copper/No connector required, Connector Code 38P - Conductor Diameter Range - .936-1.011 inch (23.77-25.68mm), Heatsink Bore - N - 1.500 inch Diameter.Type Shield - N - Unknown, Metallic Screen Continuity Kit - N - not required, Armor Kit - N - not requiredFrequently Asked Questions
What is the voltage rating of this cable joint?
The ABB 69TCJS1-Q-Q has a voltage rating of 69 kV.
What is the bore diameter of the housing at the jacket/insulation transition?
The bore diameter at the jacket/insulation transition for this joint is 1.750 inches (44.45mm).
What type of housing does this transmission cable joint feature?
This transmission cable joint features a Shieldbreak housing type and Housing Style 1.
What is the manufacturer of the 69TCJS1-Q-Q cable joint?
The manufacturer of the 69TCJS1-Q-Q cable joint is ABB - Installation Products.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.