Authorized ABB Distributor (Installation Products)
ABB - Installation Products 35PCJ1M1270 - 35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

ABB Installation Products 35PCJ1M1270 35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…

UPC: 783786641628


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This ABB 35kV Power Cable Joint, SKU 35PCJ1M1270, is designed for reliable termination of single-core, high-voltage power cables. It features a single-piece housing for simplified installation and reduced potential failure points. The joint is engineered to accommodate cable insulation diameters ranging from 1.370 inches to 1.630 inches, ensuring compatibility with a defined range of cable constructions. It is suitable for aluminum conductors, supporting both stranded 4/0 AWG and solid 250 AWG conductor sizes. The UNSPSC code 39121452 categorizes this product within electrical power distribution and transmission equipment. This joint provides essential electrical insulation and mechanical protection for the cable splice, critical for maintaining system integrity in medium-voltage power distribution networks. Proper installation is key to ensuring the long-term performance and safety of the electrical connection. The single-piece design streamlines the assembly process, potentially reducing installation time and labor costs for electrical contractors and utility personnel. This product is a component within the ABB Installation Products portfolio, known for its electrical infrastructure solutions.
  • 35kV Voltage Rating
  • Single-piece housing for simplified installation
  • Accommodates cable insulation diameters from 1.370" to 1.630"
  • Suitable for aluminum conductors: 4/0 AWG Stranded / 250 AWG Solid
  • ABB Installation Products quality

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
4/0 STR AWG , 250 kcmil
Connection
Compression
Insulation
Yes
Material
Aluminum
Material
EPDM Rubber
Number Of Conductors
2
Series
Style 1
Size
14-3/8 inch long
Size
Cable Insulation Diameter 1.370 inch to 1.630 inch
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
3.2500 L
Package Weight (Metric)
1.4740 kg
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

35PCJ1L2270

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 350.

15PCJ1J1300

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 350.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.

15PCJ2G1230-F1220

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

25PCJ1J1240

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
25kV Power Cable Joint With Customer Specific Modifications

25PCJ-T

25kV Power Cable Joint With Customer Specific Modifications
35kV Power Cable Joint, Cable Insulation Diameter 1.515 inch to 1.780 inch.

35PCJ-N

35kV Power Cable Joint, Cable Insulation Diameter 1.515 inch to 1.780 inch.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.725 inch to 1.935 inch. Copper Conductor. Conductor Size AWG Stranded 1000.

35PCJ1P2410

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.725 inch to 1.935 inch. Copper Conductor. Conductor Size AWG Stranded 1000.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 600 /Solid 700.

35PCJ1N1350

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Conductor. Conductor Size AWG Stranded 600 /Solid 700.

Frequently Asked Questions

Can copper connectors be used with aluminum conductors?

No, copper compression connectors are suitable for splicing copper-to-copper conductors only and should not be used on aluminum conductors.

What types of cable splicing can PCJ joints perform?

PCJ power cable joints offer options for straight splicing of two similar cables or transition splicing of different cable sizes.

What voltage classes are available for PCJ joints?

Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

What conductor materials are compatible with PCJ joints?

PCJ joints can be used with both copper or aluminum conductors, supporting a wide range of sizes up to 1250 kcmil.

What is the maximum cable size supported by PCJ joints?

PCJ power cable joints support cable sizes up to 1250 kcmil for both straight and transition splicing applications.

Where can PCJ power cable joints be installed?

They provide a permanent, fully shielded, fully submersible splice suitable for direct-burial, underground vault, and overhead applications.

What are the two styles of PCJ power cable joints?

Style 1 is for straight splicing of two similar cables. Style 2 uses separate cable adapters for transition splicing between different cable sizes.

What safety features does the molded conductive shield provide?

The molded conductive shield provides a virtually unbreakable ground shield for true dead-front construction and has a grounding eye for connecting a ground wire.

What standards do PCJ joints and connectors meet?

The shield design meets IEEE 592 standard, and connectors meet ANSI 119.4 Class A and Class 3 ratings. Electrical ratings meet IEEE 404.

What is the continuous current rating of PCJ joints?

The continuous current rating of PCJ power cable joints is equal to that of the cable rating.

How to Install the 35PCJ1 Series Cable Joint

This guide provides step-by-step instructions for the permanent installation of the 35PCJ1 series straight joint, designed for wire shielded cables. It covers cable preparation, splice installation, and final joint assembly for safe and effective operation.

Estimated time: 2h

Tools needed:

Wire strippers, Measuring tape, Wire brush, Crimping tool, Voltage testing equipment, T&B WT3D tool (recommended for 35kV DELTECt Cable ties)

Supplies needed:

Joint Housing, Splice (Conductor Contact), Lubricant (DO NOT SUBSTITUTE), Conductor connector (user supplied), DELTECt Cable ties (TYD5135, for 35kV ONLY), #14 AWG copper wire or equivalent (if needed for grounding), Appropriate connector (for grounding wires), Cable jacket reconstruction material (where applicable)

  1. De-energize and Inspect Components

    Before beginning, ensure all apparatus in the work area are completely de-energized. Verify the absence of voltage using appropriate testing equipment. Inspect all joint components for damage, correct rating, and compatibility with the cables. Gather all required tools and supplies, and maintain a clean work environment throughout the installation.

  2. Prepare Cable Lengths and Jackets

    Overlap both cables and cut them to 12 inches (305mm) from the center line of the joint. This ensures sufficient length for shield wires to rejoin over the completed joint. Remove the cable jacket of Cable 1 to 37 inches (940mm) and Cable 2 to 21 inches (530mm) from the joint centerline, where applicable. Carefully fold back the shield wires. Finally, cut both cables precisely at the center line of the joint.

  3. Taper Cable 1 and Position Joint Housing

    Taper the edge of Cable 1's insulation shield at least 1/2 inch (13mm) to no greater than 1-1/2 inches (38mm). Clean and lubricate the insulation shield of Cable 1. Lubricate the inside bore of the joint housing on both ends. Carefully slide the joint housing onto Cable 1, pushing it up to the shield wires for temporary storage during subsequent steps.

  4. Remove Cable Insulation and Shield

    Carefully remove the cable insulation and then the insulation shield from both Cable 1 and Cable 2 according to the dimensions 'X' and 'Y' provided in the documentation for your specific conductor size (e.g., 500-750 MCM or 1000 MCM). Exercise extreme caution to avoid cutting or nicking the remaining cable insulation or the conductor during this process.

  5. Crimp Conductor Splice

    If conductors are aluminum, wire-brush them thoroughly and immediately insert them into the splice. Verify the dimension between cable insulations against the 'Max Check Before' dimension table; if it exceeds this, re-do the assembly. Crimp the splice following the manufacturer's recommendations provided with the splice. Wipe off any excess inhibitor. Check the distance between cable insulations again against the 'Max Check After' dimension table; if it exceeds this, re-do the assembly. Remove any sharp protrusions or burrs generated during crimping and ensure all metal chips/filings are removed from the splice and joint assembly area.

  6. Lubricate Cables for Housing

    Clean the cables where indicated in the diagram. Apply lubricant in the direction of the arrows to create a build-up or ramp of lubricant at the edge of the insulation shield on both cables. This facilitates smooth sliding of the joint housing.

  7. Position Joint Housing and Secure (35kV)

    Slide the joint housing into its final position over the splice. Ensure proper positioning by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield. For 35kV installations ONLY: Install two DELTECt Cable ties (TYD5135) on each end of the cable entrance. Install the outer ties approximately 1/4 inch (6mm) from the splice edge, then the second ties approximately 1/4 inch (6mm) from the first, with an offset of the locking heads. Use the T&B WT3D tool (not included) to tighten and trim the ties. Remove and discard the yellow pin from the joint grounding eye.

  8. Connect Grounding and Reconstruct Jacket

    Retrain the shield wires and secure them to the ends of the joint as shown in the diagram. Insert one of the shield wires from Cable 1 (if #14 AWG or larger) through the joint grounding eye, and repeat for Cable 2. If shield wires are smaller than #14 AWG, use separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and the remaining shield wires using an appropriate connector. Finally, reconstruct the cable jacket (where applicable) over both cables and the joint housing to complete the installation.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.