ABB - Installation Products 15PCJ2L1360 - 15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Solid 750.

ABB Installation Products 15PCJ2L1360 15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable…

UPC: 783786362851


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 15PCJ2L1360 is a 15kV power cable joint designed for reliable medium-voltage cable connections. This Style 2 joint features a universal housing and separate cable adapters, accommodating aluminum conductors with insulation diameters between 1.180 inch and 1.465 inch. The joint supports 750 AWG solid aluminum conductors, making it suitable for high-capacity power distribution systems. The universal housing design simplifies installation by allowing compatibility with a range of cable sizes within the specified diameter limits. This joint is engineered for medium-voltage applications where durability and electrical integrity are critical. The separate cable adapters provide flexibility in matching different cable types, reducing the need for custom configurations. Ideal for utility, industrial, and commercial power systems requiring dependable 15kV-rated connections. The ABB 15PCJ2L1360 ensures consistent performance in demanding environments, with a focus on long-term reliability and minimal maintenance requirements.
  • 15kV rated power cable joint for medium-voltage applications
  • Universal housing with separate cable adapters for flexible installation
  • Supports 750 AWG solid aluminum conductors
  • Accommodates cable insulation diameters from 1.180 to 1.465 inches
  • Designed for reliable, long-term electrical connections in power systems

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
750 kcmil
Connection
Compression
Insulation
Yes
Material
Aluminum
Material
EPDM Rubber
Number Of Conductors
2
Series
Power Cable Joint Style 2
Size
21 inch long
Size
1.180 inch to 1.465 inch
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
3.2500 L
Package Weight (Metric)
1.4740 kg
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 750.

15PCJ1M2360

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 750.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250. Cold-Shrinkable Jacket Seal Included.

35PCJ1K1270-S

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250. Cold-Shrinkable Jacket Seal Included.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.

15PCJ2G1230

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Solid 350.

15PCJ1J1290

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Solid 350.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.725 inch to 1.935 inch. . Copper Conductor. Conductor Size AWG Stranded 1000.

15PCJ1P2410

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.725 inch to 1.935 inch. . Copper Conductor. Conductor Size AWG Stranded 1000.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Stranded 500. Copper Conductor. Conductor Size AWG Stranded 450.

25PCJ1L2330-2320

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Stranded 500. Copper Conductor. Conductor Size AWG Stranded 450.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 450.

25PCJ1M1320

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 450.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.

35PCJ1K2250

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.

Frequently Asked Questions

What is the operating voltage for this cable joint?

This cable joint is rated for 15kV medium-voltage applications.

What conductor sizes does this joint support?

The joint supports 750 AWG solid aluminum conductors.

What cable insulation diameter range does this joint accommodate?

The joint accommodates cable insulation diameters from 1.180 inch to 1.465 inch.

What type of housing does this cable joint feature?

The joint features a universal housing with separate cable adapters.

Is this joint compatible with copper conductors?

The joint is designed for aluminum conductors; compatibility with copper is not specified.

How to Install the 15PCJ2L1360 Straight Joint

This guide provides step-by-step instructions for the permanent, fully shielded, and submersible installation of the 15PCJ2L1360 straight joint on aluminum or copper conductor, wire-shielded cables. Ensure all safety precautions are followed for high voltage equipment.

Estimated time: 1h 30m

Tools needed:

Insulation stripping tool, Wire brush, Crimp tool, Hex wrench

Supplies needed:

15PCJ2L1360 Joint Kit (includes Joint Housing, Splice, Cable Adapters, Lubricant, Retaining Collars, Hose Clamp), Electrical tape, User-supplied connector (for grounding wires), Heat/cold shrink kit (for cable jacket reconstruction), Bonding cable(s) (if required), Insulating and sealing tapes (if required)

  1. Ensure Safety and Inspect Components

    DANGER: De-energize all apparatus before installation or removal. Install and operate according to individual user, local, and national work rules. Do not touch or move energized products in the work area. Inspect all kit contents for completeness and damage. Verify proper fit of all components with the specific cable and mating products. Examine mating cable ends, ensuring they are free from moisture and contaminants. CAUTION: This product should only be installed by competent personnel trained in high voltage electrical equipment safety practices.

  2. Prepare Cable Ends

    Remove any graphite coatings from the cable jacket for 12 inches (30.5 cm) beyond the cable jacket cut. Avoid sanding to prevent embedding conductive particles within the cable jacket's insulation. If the conductor contains strand-filled or water-blocking material, contact the cable manufacturer for their recommended welding or crimping procedures.

  3. Install Joint Housing on Cable 1

    Carefully remove the cable jacket (if applicable) from both cables for a distance of 11-1/4 inches (285.7 mm) using the stripping guide. Fold back the shield wires on Cable 1 and tape the ends to the jacket, allowing enough extra length to rejoin over the joint later. Clean the surface of the insulation shield, shield wires, and jacket for a distance of 30 inches (760 mm). Slide the joint housing onto Cable 1 to a distance of 30 inches (760 mm) from the end.

  4. Prepare Cable Insulation

    Using the stripping guide, carefully remove the insulation shield and cable insulation. DO NOT CUT OR NICK THE INSULATION, as this could result in failure of the assembly. Wrap two turns of electrical tape 1 inch (25 mm) from the edge of the insulation shield on both cables to serve as a marker. Clean the cable insulation thoroughly, then lubricate it to create a build-up or ramp of lubricant at the edge of the insulation shield.

  5. Install Cable Adapters

    Take one cable adapter and lubricate the inside of both ends. Install the lubricated cable adapter onto Cable 1 until it meets the tape marker. Repeat this process for the other cable adapter on Cable 2.

  6. Install Retaining Collars

    Select a retaining collar and partially thread the appropriate size setscrews (refer to instructions packaged with the collars). Position the retaining collar over the insulation, flush against the cable adapter. Using the supplied hex wrench, tighten each set screw only one or two turns at a time to ensure the collar remains centered over the insulation. Continue tightening the set screws until they are below the surface of the collar. Repeat this procedure for the retaining collar on Cable 2.

  7. Install the Splice

    Thoroughly clean the ends of both cable adapters and the exposed cable conductors. Install the supplied hose clamp around the adapter on the side opposite to where the housing is stored, and tape over the hose clamp to create a smooth surface, holding the adapter in place. Wirebrush the exposed conductors of both cables immediately before insertion. Insert the prepared conductors into the splice. Ensure the 'Check' dimension (distance between cable adapters) does not exceed 8-1/2 inches (215 mm); if it does, redo the assembly. Crimp the splice following the recommendations provided with it. Wipe off any excess inhibitor. Clean and lubricate the outside surface of the cable adapters before sliding the housing into its final position.

  8. Complete Joint Assembly and Grounding

    Slide the joint housing into its final position, centering it over the cable adapters. Remove all temporary tape. Ensure that no cable or adapter insulation is exposed after the joint is positioned. Reshape the shield wires and secure them to the ends of the joint. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye. Repeat for Cable 2. If shield wires are smaller than #14 AWG, use a separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and the remaining shield wires using an appropriate user-supplied connector.

  9. Reconstruct Cable Jacket

    Reconstruct the cable jacket (where applicable) over both cables and also over the joint housing. Note that heat/cold shrink materials for this step are not included in the kit and must be supplied separately.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.