Authorized ABB Distributor (Installation Products)
ABB - Installation Products 35PCJ1K2250 - 35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.

ABB Installation Products 35PCJ1K2250 35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…

UPC: 783786391059


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

ABB Installation Products 35PCJ1K2250 is a 35kV power cable joint designed for medium-voltage distribution systems. This joint features a single-piece housing optimized for cable insulation diameters ranging from 1.090 to 1.310 inches, ensuring compatibility with a broad spectrum of cable types. The joint accommodates both stranded 2/0 AWG and solid 3/0 AWG copper conductors, providing flexibility for various installation requirements. Engineered for reliability in medium-voltage applications, this joint is suitable for underground and aerial installations where 35kV-rated connections are required. The single-piece housing simplifies installation by reducing assembly steps and minimizing potential failure points compared to multi-part joints. It meets industry standards for 35kV systems, including dielectric strength and mechanical durability requirements. The 35PCJ1K2250 is part of ABB’s Installation Products line, a trusted manufacturer with decades of experience in electrical infrastructure solutions. This joint is ideal for utilities, industrial facilities, and commercial installations requiring durable, high-voltage cable connections. No additional tools or complex procedures are needed for installation, reducing downtime during maintenance or upgrades.
  • 35kV-rated power cable joint for medium-voltage systems
  • Single-piece housing for simplified installation and reduced failure points
  • Accommodates cable insulation diameters from 1.090 to 1.310 inches
  • Supports stranded 2/0 AWG and solid 3/0 AWG copper conductors
  • Compatible with underground and aerial 35kV distribution applications

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
2/0 STR AWG , 3/0 SOL AWG
Connection
Compression
Insulation
Yes
Material
Copper
Material
EPDM Rubber
Number Of Conductors
2
Series
35kV Power Cable Joint Style 1
Size
14-3/8 inch long
Size
1.090 inch to 1.310 inch
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
2.5000 L
Package Weight (Metric)
1.1340 kg
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.

35PCJ1K1250

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.

25PCJ1J1250

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 2/0 /Solid 3/0.
28kV Power Cable Joint Style 1 with Single Piece Housing for Canada, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.

28PCJ1H1230

28kV Power Cable Joint Style 1 with Single Piece Housing for Canada, Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

35PCJ1K1270

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Stranded 550 /Solid 650.

15PCJ1L2340

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Conductor. Conductor Size AWG Stranded 550 /Solid 650.
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.

25PCJ2H1240-G1220

25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 750. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded 450.

15PCJ2M1380-K1320

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 750. Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded 450.
35kV Power Cable Joint, Cable Insulation Diameter 1.900 inch to 2.120 inch.

35PCJ-Q

35kV Power Cable Joint, Cable Insulation Diameter 1.900 inch to 2.120 inch.

Frequently Asked Questions

Can copper connectors be used with aluminum conductors?

No, copper compression connectors are suitable for splicing copper conductors to copper conductors only and should not be used on aluminum conductors.

What environments are suitable for PCJ power cable joint installation?

PCJ power cable joints can be installed in direct-burial, underground vault, and even overhead applications. They provide a permanent, fully shielded, fully submersible splice.

What is the difference between Style 1 and Style 2 PCJ joints?

Style 1 is for straight splicing of two similar cables. Style 2 includes separate cable adapters for transition splicing between two different cable sizes.

What types of conductors are compatible with these joints?

These joints can be used with copper or aluminum conductors, accommodating a wide range of sizes up to 1250 kcmil.

What voltage classes are available for PCJ cable joints?

Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

What are Elastimold PCJ power cable joints used for?

They are used for straight splicing of two similar cables or transition splicing of different cable sizes, up to 1250 kcmil, in new or existing installations.

What types of conductors are compatible with these joints?

These joints can be used with copper or aluminum conductors, accommodating a wide range of sizes up to 1250 kcmil.

What are Elastimold PCJ power cable joints used for?

They are used for straight splicing of two similar cables or transition splicing of different cable sizes, up to 1250 kcmil, in new or existing installations.

What voltage classes are available for PCJ cable joints?

Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

What is the difference between Style 1 and Style 2 PCJ joints?

Style 1 is for straight splicing of two similar cables. Style 2 includes separate cable adapters for transition splicing between two different cable sizes.

How to Install the 15/25/35PCJ1 Series Straight Joint

This guide provides step-by-step instructions for the permanent installation of the 15/25/35PCJ1 series straight joint, designed for aluminum to aluminum and/or aluminum to copper conductor, wire shielded cables. Installation must be performed by competent personnel trained in high voltage electrical equipment safety practices to prevent serious injury or product damage.

Estimated time: 2h

Tools needed:

Cable stripping tools, Wire-brush (for aluminum conductors), Crimping tool (for splice), T&B WT3D tool (recommended for 35kV DELTECt Cable ties)

Supplies needed:

Appropriate connector (for grounding wires), DELTECt Cable ties (TYD5135, for 35kV ONLY), #14 AWG copper wire or equivalent (if shield wires are smaller than #14 AWG), Cleaning supplies

  1. De-energize Apparatus and Inspect Components

    Ensure all apparatus in the work area are de-energized during installation or removal of any parts; do not touch or move energized products. Inspect the package contents to confirm they are complete and undamaged. Verify all components for proper fit with the cable and/or mating products.

  2. Prepare Work Area and Gather Tools

    Read the entire installation instructions before starting. Have all required tools at hand and maintain cleanliness throughout the entire procedure to prevent contamination.

  3. Prepare Cable Ends

    Overlap both cables and cut them to 12 inches (305mm) from the joint's centerline to ensure sufficient length of shield wires. Where applicable, remove the cable jacket of Cable 1 to 37 inches (940mm) and Cable 2 to 21 inches (530mm). Fold back the shield wires, then cut both cables at the joint's centerline.

  4. Taper Cable 1 and Store Housing

    Taper the edge of Cable 1's insulation shield at least 1/2 inch (13mm) to no greater than 1-1/2 inches (38mm). Clean and lubricate the insulation shield. Lubricate the inside bore of the joint housing on both ends. Slide the housing onto Cable 1 up to the shield wires.

  5. Prepare Cables for Splice Installation

    Carefully remove the cable insulation and then the insulation shield from both cables according to the specified dimensions (X and Y). WARNING: DO NOT CUT OR NICK THE CABLE INSULATION OR CONDUCTOR, as this will result in product failure.

  6. Install and Crimp the Splice

    If conductors are aluminum, wire-brush them immediately before inserting into the splice. Insert the conductors into the splice and check the dimension against the 'Max Check Before' table. Crimp the splice following its provided recommendations. If the dimension exceeds the maximum, redo the assembly.

  7. Clean and Lubricate Splice Area

    Wipe off any excess inhibitor where applicable. Check the distance between cable insulations against the 'Max Check After' table; redo assembly if it exceeds the maximum. Remove any sharp protrusions or burrs generated during crimping. Clean the cables where indicated and lubricate in the direction of the arrows to provide a build-up or ramp of lubricant at the edge of the insulation shield.

  8. Position Joint Housing

    Slide the joint housing into its final position. Proper positioning is ensured by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield.

  9. Install 35kV Cable Ties (35kV ONLY)

    For 35kV applications only, install two DELTECt Cable ties on each end of the cable entrance. Begin by installing the outer ties approximately 1/4 inch (6mm) from the splice edge, then install the second ties approximately 1/4 inch (6mm) from the first with an offset of the locking heads. Use the T&B WT3D tool (not included) to tighten and trim the ties. Remove and discard the yellow pin from the joint grounding eye.

  10. Connect Grounding Wires

    Retrain the shield wires and secure them to the ends of the joint. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye, and repeat for Cable 2. If shield wires are smaller than #14 AWG, use separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and remaining shield wires using an appropriate connector.

  11. Reconstruct Cable Jacket

    Reconstruct the cable jacket (where applicable) over both cables and the joint housing to complete the installation.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.