ABB - Installation Products 35PCJ1K1230 - 35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.

ABB Installation Products 35PCJ1K1230 35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…

UPC: 783786799527


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 35PCJ1K1230 is a fully rated 35kV Power Cable Joint, Style 1, designed for permanent, fully shielded, and fully submersible straight splices. This Elastimold® joint meets IEEE Standard 404 and is suitable for both new installations joining cable runs and repairs to broken cables. It is rated for 35kV applications, offering 200kV BIL (Impulse Withstand) and 69kV AC Withstand. The joint is engineered to accept cable insulation diameters ranging from 0.850 inches to 2.120 inches, with this specific model accommodating 1.090 inches to 1.310 inches. It is designed for aluminum conductors, specifically AWG Stranded #1 or Solid 1/0 AWG. The molded conductive shield ensures a virtually indestructible ground shield for true deadfront construction, and the molded conductive insert prevents electrical stress on entrapped air. The cable entrance provides electrical and water seal integrity, engaging the cable's insulation shielding to eliminate the need for taping. The grounding eye offers a convenient point to connect a ground wire to the molded conductive shield, placing it at ground potential. The pin and socket interlock is designed to withstand pulls of up to 500 lbs, making it suitable for direct burial or vault installations. Connectors meet ANSI C119.4 Class A and Class 3 ratings. Cyclic aging tests include 30 days at 60.6kV AC continuous with load current for 8 hours daily, reaching 130°F conductor temperature. The shield design meets IEEE Standard 592. This power cable joint is ideal for industrial and utility applications requiring dependable medium voltage cable connections.
  • Fully Rated 35kV Power Cable Joint, Style 1
  • Accommodates cable insulation diameters from 1.090" to 1.310"
  • Designed for AWG Stranded #1 / Solid 1/0 AWG Aluminum conductors
  • Fully shielded, fully submersible molded rubber housing
  • Meets IEEE Standard 404 for 35kV applications

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
#1 STR AWG , 1/0 SOL AWG
Connection
Compression
Insulation
Yes
Material
Aluminum
Material
EPDM Rubber
Number Of Conductors
2
Series
Style 1
Size
14-3/8 inch long
Size
1.090" to 1.310"
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
35 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
35kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.

35PCJ2J1230

35kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.

35PCJ1L1230

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Conductor. Conductor Size AWG Stranded #2/Solid #1.

25PCJ1H2220

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Conductor. Conductor Size AWG Stranded #2/Solid #1.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Solid 500.

15PCJ1M1310

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Solid 500.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Conductor. Conductor Size AWG Solid 350.

15PCJ1K2290

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Conductor. Conductor Size AWG Solid 350.
28kV Power Cable Joint Style 1 with Single Piece Housing for Canada, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.

28PCJ1L1330

28kV Power Cable Joint Style 1 with Single Piece Housing for Canada, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.
25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 500.

25PCJ2M2310

25kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 500.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 350. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

15PCJ2L1300-J1270

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 350. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

Frequently Asked Questions

What are the two styles of PCJ power cable joints?

Style 1 has a single-piece housing for straight splicing. Style 2 has a universal housing with separate cable adapters for transition splicing.

What conductor types and sizes are compatible with PCJ joints?

PCJ joints can be used with copper or aluminum conductors, supporting a wide range of sizes up to 1250 kcmil.

What types of cable splicing can PCJ power cable joints perform?

PCJ joints offer options for straight splicing of two similar cables or transition splicing of different cable sizes.

Where can Elastimold PCJ power cable joints be installed?

These joints provide a permanent, fully shielded, fully submersible splice suitable for direct-burial, underground vault, and overhead applications.

What is the maximum pull force the pin-and-socket interlock can withstand?

The pin-and-socket interlock in PCJ power cable joints is designed to withstand a pull force of up to 500 lb.

What standards do the PCJ joint shield and connectors meet?

The shield design meets IEEE 592 standard, and the connectors meet ANSI 119.4 Class A and Class 3 ratings.

What is the continuous current rating for PCJ power cable joints?

The continuous current rating for PCJ power cable joints is equal to that of the cable rating.

What is the short-time current rating for PCJ power cable joints?

The short-time current rating for PCJ power cable joints is equal to that of the cable rating, up to 35 kA.

Are there specific connector requirements for different conductor materials?

Aluminum compression connectors are for Al-Al or Al-Cu. Copper compression connectors are for Cu-Cu only and must not be used on aluminum conductors.

How should transition joints for different cable sizes be ordered?

When constructing a catalog number for a transition joint, list the larger connector first and the smaller connector second.

How to Install the 35PCJ1 Series Straight Joint

This guide provides step-by-step instructions for the permanent, fully shielded, and submersible installation of the 35PCJ1 series straight joint for wire shielded cables, connecting aluminum to aluminum and/or aluminum to copper conductors. Ensure all safety precautions are followed.

Estimated time: 1h 30m

Tools needed:

Cable strippers/knife, Wire brush, Crimping tool, Deburring tool/knife, Measuring tape, T&B WT3D tool (for 35kV installations)

Supplies needed:

Joint Housing, Splice (Conductor Contact), Lubricant (DO NOT SUBSTITUTE), Appropriate connector (for grounding wires), DELTECt Cable ties (TYD5135, for 35kV installations), #14 AWG copper wire or equivalent (if needed), Cleaning cloths/wipes, Cable jacket reconstruction material

  1. Perform Initial Safety Checks and Inspection

    DANGER: Ensure all apparatus is de-energized before starting installation. Inspect the package contents and all components for completeness, damage, and compatibility with the cables and mating parts. If supplied with protective shipping covers, remove them and replace with appropriate HV insulated caps or connectors before energizing the circuit.

  2. Prepare Cables for Jointing

    Overlap both cables and cut them to 12 inches (305mm) from the joint centerline to ensure sufficient shield wire length. Where applicable, remove the cable jacket of Cable 1 to 37 inches (940mm) and Cable 2 to 21 inches (530mm). Fold back the shield wires. Finally, cut both cables precisely at the joint centerline.

  3. Prepare Cable 1 and Store Housing

    Taper the edge of Cable 1 insulation from at least 1/2 inch to no greater than 1-1/2 inches (13mm to 38mm). Clean and lubricate the insulation shield of Cable 1. Lubricate the inside bore of the joint housing on both ends. Slide the joint housing onto Cable 1 up to the shield wires for temporary storage.

  4. Prepare Cables for Splice Installation

    Carefully remove the cable insulation and then the insulation shield from both Cable 1 and Cable 2. DO NOT CUT OR NICK THE CABLE INSULATION OR CONDUCTOR. Refer to the provided dimension table for precise 'X' and 'Y' measurements based on your conductor size (e.g., 500-750 MCM or 1000 MCM).

  5. Install the Splice

    If conductors are aluminum, wire-brush them thoroughly and immediately insert them into the splice. Crimp the splice following the manufacturer's recommendations. Wipe off any excess inhibitor. Check the distance between cable insulations against the 'Max Check After' dimension; if it exceeds, redo the assembly. Remove any sharp protrusions or burrs from the crimped splice and the joint assembly area. Clean cables where indicated and lubricate to create a build-up at the edge of the insulation shield.

  6. Complete Joint Assembly and Grounding

    Slide the joint housing into its final position, ensuring proper alignment by observing and equalizing the deformation of the joint ends. For 35kV installations ONLY: Install two DELTECt Cable ties on each end of the cable entrance, approximately 1/4 inch from the splice edge and 1/4 inch from the first tie with offset locking heads; use a T&B WT3D tool to tighten and trim. Remove and discard the yellow pin from the joint grounding eye. Retrain shield wires and secure them to the ends of the joint. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye, and repeat for Cable 2 (use separate #14 AWG copper wire if shield wires are smaller). Connect joint grounding wires and remaining shield wires using an appropriate connector. Reconstruct the cable jacket (where applicable) over both cables and the joint housing.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.