ABB - Installation Products 274FLR3-D0270 - Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Capactive Test Ports, Large Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 4/0 AWG Stranded Compressed

ABB Installation Products 274FLR3-D0270 Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port…

UPC: 783786522507


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This ABB Molded Current Limiting Fuse Housing, SKU 274FLR3-D0270, is designed for reliable protection in medium-voltage electrical systems. It features a nominal fuse voltage rating of 17.2kV, ensuring compatibility with standard medium-voltage infrastructure. The housing is equipped with two capacitive test ports, facilitating safe and efficient testing of fuse status and system integrity without requiring direct contact with live components. Engineered for a specific range of cable insulation diameters, this unit accommodates cables from 0.890 inches to 1.220 inches (25-31mm). It is suitable for use with aluminum conductors, specifically sized for 4/0 AWG stranded compressed conductors. The molded construction provides robust insulation and environmental protection for the current-limiting fuse it houses. This component is essential for safeguarding electrical equipment from damaging overcurrents and short circuits in industrial and utility applications. Key Specifications: - Manufacturer: ABB - Installation Products - SKU: 274FLR3-D0270 - Nominal Fuse Voltage Rating: 17.2kV - Fuse Test Ports: Two Capacitive Test Ports - Cable Insulation Diameter Range: 0.890 inch - 1.220 inch / 25-31mm - Conductor Size: 4/0 AWG Stranded Compressed Aluminum
  • Nominal Fuse Voltage Rating: 17.2kV
  • Two Capacitive Test Ports for safe testing
  • Accommodates cable insulation diameters from 0.890" to 1.220" (25-31mm)
  • Designed for 4/0 AWG Stranded Compressed Aluminum conductors
  • Molded construction for robust protection

Specifications

Amperage Rating
200 A
Application
Protect Light Duty Underground Distribution Systems
Color
Black
Conductor Range
4/0 STR/COMPR AWG , 250 kcmil
Insulation
True
Length
21.12 in
Length
536.448 mm
Material
EPDM-Rubber
Special Features
Full-Range Current-Limiting Fusing with 50kA Interrupting Capability. Hotstick Operable 25/28kV Loadbreak Elbow Switching
Standard
IEEE 386, ANSI C37.40, ANSI C37.41, ANSI C37.47
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Fused Elbow Connector with Test Point
Voltage Rating
15.5 to 16.2 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.

162LR-D5270-S

200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact.

168FLR3-B0220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Capactive Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid Compact

274FLR3-C0220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Capactive Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid Compact
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 4/0 AWG Stranded Compressed.

168AFLR3C0270

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 4/0 AWG Stranded Compressed.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 6 AWG Stranded/Compressed.

168FLR1B0180

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 6 AWG Stranded/Compressed.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Capactive Test Ports, Large Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 3/0 AWG Stranded Compressed, 4/0 AWG Solid Compact

274FLR3-D0260

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Capactive Test Ports, Large Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 3/0 AWG Stranded Compressed, 4/0 AWG Solid Compact
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 4/0 AWG Stranded Compressed.

168AFLR3-D0270

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 4/0 AWG Stranded Compressed.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact.

168FLR1-C0220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact.

Frequently Asked Questions

What is the main application of the 274FLR fused elbow?

The 274FLR fused elbow protects light duty underground distribution systems, including sub-loops and radial taps, by replacing existing 200 Amp loadbreak tap elbows.

How is the housing size selected for the 274FLR?

The housing size (H code) is selected based on the desired fuse size and voltage, such as 3-45A 8.3kV or 6-20A 15.5kV fuses.

Does the 274FLR have a blown fuse indicator?

Yes, the 274FLR has built-in voltage test points for quick and convenient blown fuse indication.

What items are included in the 274FLR kit?

Each kit includes an elbow connector housing, crimp connector, probe lug, lubricant tubes, installation instructions, a crimp chart, and a V.D Cap-Peroxide.

How do I select the correct connector for my cable size?

The proper compression lug code (X code) is chosen according to the conductor size from the Conductor Code Table, which lists AWG or kcmil sizes.

Are sealing and grounding kits recommended for safety?

Yes, for safety purposes, a sealing and grounding kit with the loadbreak elbow is highly recommended.

Is the 274FLR fused elbow submersible?

Yes, the 274FLR fused elbow is fully sealed and submersible when used with ECS series sealing kits.

How does the 274FLR facilitate fuse replacement?

The 274FLR features a split center section designed for easy fuse replacement.

Can the 274FLR fused elbow be operated with a hot stick?

Yes, the 274FLR Loadbreak Fused Elbow features hot stick operable 25/28kV loadbreak elbow switching.

Is the fuse included with the 274FLR elbow connector?

No, the fuse for the 274FLR fused elbow is ordered separately.

How to Install the 168FLR or 274FLR Loadbreak Fused Elbow Connector

This guide provides step-by-step instructions for the installation and initial setup of the 168FLR or 274FLR Loadbreak Fused Elbow Connector, including cable preparation, assembly, and neutral connection.

Estimated time: 1h 30m

Tools needed:

Probe Wrench, Allen Wrench (torque limiting), Wire brush, Crimp tool, Hotstick, Vent stick

Supplies needed:

Cable Half Housing, Elbow Half Housing, Fuse, Compression Lug, Probe, Probe Connector, Hose Clamp, Lubricant, 200ECS Cold Shrink Cable Seal (optional), Copper wire (No. 14 AWG / 2.5mm), Appropriate grounding connector

  1. Perform Safety and Pre-Installation Checks

    DANGER: De-energize all apparatus before beginning installation or removal of parts, except for test point caps and indicators that can be installed and operated energized. Do not touch or move energized products in the work area. Inspect all parts for damage, correct rating, and compatibility with mating parts. Check threads by threading the probe into the compression lug. Ensure all required tools are at hand and maintain cleanliness throughout the procedure.

  2. Prepare the Cable for Termination

    Using the bushing centerline as a reference, cut excess cable, then remove the jacket for the specified length. Unwrap and fold the concentric neutral wires back over the jacket and bind them. Squarely cut the cable end, then wire brush bare aluminum conductors and immediately install the compression lug, crimping it according to the manufacturer's chart. Remove the insulation shield 5-1/2 inches from the lug end, bevel the insulation 1/8 inch maximum, and thoroughly clean it to remove all traces of conductive residue.

  3. Assemble the Cable Half Housing and Fuse

    Apply the supplied lubricant to the outside of the connector, cable insulation, conductive shield, and the cable entrance end of the Fused Elbow cable half. Insert the connector and cable into the cable half until the top end of the connector protrudes beyond surface 'A'. Insert the threaded terminal end of the fuse into the cable half of the Fused Elbow and thread it into the cable connector, hand tightening it. CAUTION: Fuse stud will fracture if over torqued. Pull the housing up against the bottom of the tightened fuse.

  4. Install and Orient the Probe Connector

    Assemble the probe connector to the fuse terminal. Rotate the probe connector so that its flats are perpendicular to the bushing with which it will mate, then lock it in position. Tighten the setscrews using the special torque-limiting allen wrench supplied in the fuse kit. Rotate the cable half of the Fused Elbow so that the test point is perpendicular to the flats on the probe connector.

  5. Assemble the Elbow Half Housing and Probe

    Apply lubricant to the elbow half of the fused elbow and assemble it to the cable half, ensuring the cuff of the cable half will overlap the elbow half by 3/4 inch. Make sure that the probe connector faces the opening of the fused elbow half, and the two test points should be in line with each other. Insert the probe into the probe connector, pushing on the cable if necessary to align it with the fuse. Hand start the threads, taking care not to cross-thread the probe. To tighten, use the special torque-limiting allen wrench supplied, inserting the short end into the hole in the probe; tighten until the wrench bends and remains bent. Position the hose clamp as shown and tighten, but DO NOT OVERTIGHTEN.

  6. Connect the Concentric Neutral Wires

    Using a separate copper wire (No. 14 AWG / 2.5mm or equivalent), insert one end through each grounding eye on the elbow housing and cable housings, twisting tightly, taking care not to damage the eye. If a 200ECS jacket seal kit is used, finish installing it. Twist all neutral wires together, exercising care not to damage grounding eyes, and connect them to ground using an appropriate connector. Provide adequate slack in the wires for elbow operation.

  7. Prepare for Connection to Bushing

    Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. LUBRICATE ONLY IF THE TRANSFORMER AND ELBOW ARE KNOWN TO BE DE-ENERGIZED. The elbow is now ready for operation using a full insulated 'hotstick' type live-line tool, following the company's safe work practices and operating instructions. DO NOT OPERATE BY HAND.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.