ABB - Installation Products 168FLR3A0220 - Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid/Compact.

ABB Installation Products 168FLR3A0220 Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port…

UPC: 075114232418


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This ABB Molded Current Limiting Fuse Housing, SKU 168FLR3A0220, is engineered for robust and reliable protection within medium-voltage electrical systems. The molded construction of this housing ensures durability and consistent performance. It is rated for a nominal fuse voltage of 8.3 kV, a critical parameter for safe and effective operation in its intended applications. For enhanced maintainability and diagnostic capabilities, the housing is equipped with two capacitive test ports. These ports allow for convenient and accurate fuse testing procedures without the need to disrupt the overall system integrity, contributing to reduced downtime and improved operational efficiency. The design of this fuse housing features a large housing volume, specifically accommodating a wide range of cable insulation diameters. This flexibility extends from a minimum of 0.575 inches up to a maximum of 0.740 inches, which is equivalent to 15-19mm. This broad insulation diameter range ensures compatibility with various cable types and sizes commonly found in medium-voltage installations. For conductor connections, the 168FLR3A0220 housing is designed to support aluminum conductors. It is compatible with aluminum conductors sized at 2 AWG stranded compressed, providing a secure and efficient connection for this conductor type. Additionally, it supports 1 AWG solid or compact aluminum conductors, offering versatility in conductor selection based on specific project requirements and available materials. The ABB Installation Products division is dedicated to providing dependable and high-performance solutions for electrical infrastructure. This molded current limiting fuse housing is a prime example of their commitment to functional design, operational safety, and precise current limitation for critical medium-voltage circuits. Its specifications are meticulously tailored for applications demanding reliable insulation and effective current limiting capabilities.
  • Nominal Fuse Voltage Rating: 8.3 kV
  • Fuse Test Port: Two Capacitive Test Ports
  • Housing Size: Large
  • Cable Insulation Diameter: 0.575 inch - 0.740 inch / 15-19mm
  • Conductor Size: 2 AWG Stranded Compressed, 1 AWG Solid/Compact Aluminum

Specifications

Amperage Rating
200 A
Application
Protect Light Duty Underground Distribution Systems
Color
Black
Conductor Range
#2 STR/COMPR AWG , #1 SOL/COMPT AWG
Insulation
True
Length
21.12 in
Length
536.448 mm
Material
EPDM-Rubber
Special Features
Full-Range Current-Limiting Fusing with 50kA Interrupting Capability. Hotstick Operable 15kV Loadbreak Elbow Switching
Standard
IEEE 386, ANSI C37.40, ANSI C37.41, ANSI C37.47
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Fused Elbow Connector
Voltage Rating
8.3 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
9.2700 L
Package Weight (Metric)
4.2050 kg
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact. no Sealing Kit

168FLR1-B5220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact. no Sealing Kit
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Direct Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid/Compact.

274AFLR1-C0230

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Direct Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Bi-Metal Conductor size 3/0 AWG Stranded/Compressed, 4/0 AWG Solid/Compact.

168FLR3-C5260

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Bi-Metal Conductor size 3/0 AWG Stranded/Compressed, 4/0 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2/0 AWG Stranded Compressed, 3/0 AWG Solid Compact

274FLR1-B0250

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2/0 AWG Stranded Compressed, 3/0 AWG Solid Compact
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 4/0 AWG Stranded/Compressed.

168FLR3-C0270

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 4/0 AWG Stranded/Compressed.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 1 AWG Stranded/Compressed, 1/0 AWG Solid/Compact.

168FLR3-C0230

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 1 AWG Stranded/Compressed, 1/0 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid Compact

274FLR1-D0220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid Compact
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Direct Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 15-19mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid/Compact.

274AFLR1-B0220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Direct Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 15-19mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid/Compact.

Frequently Asked Questions

What items are included in each 168FLR kit?

Each kit includes an elbow connector housing, crimp connector, probe lug, lubricant tubes, installation instructions, and a crimp chart.

What types of conductors are compatible with the compression lugs?

Copper compression lugs are for copper conductors only. Bi-metal compression lugs are suitable for copper or aluminum conductors.

Is the 168FLR suitable for submersible applications?

Yes, the 168FLR is fully sealed and submersible.

What is the current rating range for the 168FLR?

The current rating range for the 168FLR is 3-80 Amps.

What is the interrupting capability of the 168FLR?

The 168FLR has a symmetrical interrupting capability of 50,000 Amps.

What is the maximum rated fuse voltage?

The maximum rated fuse voltage for the 168FLR is 10kV.

What is the nominal fuse voltage for the 168FLR?

The nominal fuse voltage for the 168FLR is 8.3kV.

What is the primary application of the 168FLR?

The 168FLR protects light duty underground distribution systems, including sub-loops and radial taps, by replacing existing 200 Amp loadbreak tap elbows.

What types of conductors are compatible with the compression lugs?

Copper compression lugs are for copper conductors only. Bi-metal compression lugs are suitable for copper or aluminum conductors.

What is the nominal fuse voltage for the 168FLR?

The nominal fuse voltage for the 168FLR is 8.3kV.

How to Install the 168FLR/274FLR Loadbreak Fused Elbow Connector

This guide provides step-by-step instructions for the installation and initial setup of the 168FLR or 274FLR Loadbreak Fused Elbow Connector, including cable preparation, assembly, and neutral connection. Ensure all apparatus are de-energized before beginning installation.

Estimated time: 1h 30m

Tools needed:

Wire brush, Crimp tool, Special torque limiting allen wrench, Hotstick

Supplies needed:

Compression Lug, Fuse, Lubricant, Hose Clamp, Probe, Probe Connector, Copper wire (No. 14 AWG / 2.5mm or equivalent), Optional: 200ECS Cold Shrink Cable Seal

  1. Pre-Installation Safety and Inspection

    DANGER: De-energize all apparatus before starting installation. Inspect package contents for completeness and damage. Verify all components fit correctly with the cable and mating products. Check threads by threading the probe into the compression lug; replace damaged components if resistance is encountered. Read all instructions thoroughly and have all required tools at hand, maintaining cleanliness throughout the procedure.

  2. Cable Training and Jacket Removal

    Using the bushing centerline as a reference, cut excess cable off 20 inches minimum beyond the bushing. Slide the optional 200ECS Cold Shrink Cable Seal onto the cable if used. Remove the cable jacket for the specified length (distance of 'A' + 7-3/8 inches from the bushing centerline). If not using a cable seal kit, unwrap and fold the concentric neutral wires back over the jacket and bind them. Squarely cut off the cable a distance of 'A' from the bushing centerline, leaving 7-3/8 inches minimum of cable to terminate.

  3. Conductor Preparation and Lug Installation

    Cut 1-1/8 inches from the cable end, ensuring a square cut and taking care not to nick the conductor. Wire brush the bare aluminum conductors and immediately install the compression lug, rotating it to spread the inhibitor. Crimp the unthreaded end of the compression lug to the conductor (refer to the crimp chart packaged with the lug for tool information), starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe off any excess inhibitor from the outside of the lug and cable.

  4. Insulation Shield Removal and Cleaning

    Remove the insulation shield 5-1/2 inches from the end of the lug. Bevel the insulation end a maximum of 1/8 inch. Thoroughly clean the insulation to remove all traces of conductive residue.

  5. Lubricate and Assemble Cable Half

    Apply the supplied lubricant to the outside of the connector, cable insulation, conductive shield, and the cable entrance end of the Fused Elbow cable half. Insert the connector and cable into the cable half of the Fused Elbow until the top end of the connector protrudes beyond surface 'A'. This allows the fuse to be tightened before bottoming on the rubber.

  6. Install and Hand Tighten Fuse

    Insert the threaded terminal end of the fuse into the cable half of the Fused Elbow and hand-thread it into the cable connector. CAUTION: HAND TIGHTEN ONLY. The fuse stud will fracture if over-torqued. Pull the housing up against the bottom of the tightened fuse.

  7. Assemble and Position Probe Connector

    Assemble the probe connector to the fuse terminal. Rotate the probe connector so that its flats are perpendicular to the bushing with which it will mate. Lock the probe connector in position by tightening the setscrews using the special torque-limiting allen wrench supplied in the fuse kit. Rotate the cable half of the Fused Elbow so that its test point is perpendicular to the flats on the probe connector.

  8. Assemble Elbow Halves and Probe

    Apply the supplied lubricant to the elbow half of the fused elbow and assemble it to the cable half. The cuff of the cable half will overlap the elbow half by 3/4 inch. Ensure that the probe connector faces the opening of the fused elbow half and that the two test points are in line with each other. Insert the probe into the probe connector; it may be necessary to push on the cable to get the probe to line up with the fuse. Start the threads by hand, taking care not to cross-thread the probe. To tighten, use the special torque-limiting allen wrench supplied, inserting the short end into the hole in the probe and tightening until the wrench bends and remains bent.

  9. Secure with Hose Clamp

    Position the hose clamp as shown in the documentation and tighten it. DO NOT OVERTIGHTEN the hose clamp.

  10. Connect Concentric Neutral Wires

    Using a separate copper wire (No. 14 AWG / 2.5mm or equivalent), insert one end through each grounding eye on the elbow housing and cable housings. Twist tightly, taking care not to damage the eye. Finish installing the 200ECS jacket seal if used. Twist all neutral wires, exercising care not to damage the grounding eyes, and connect them to ground using an appropriate connector. Provide adequate slack in the wires for elbow operation.

  11. Lubricate and Connect to Bushing (De-energized)

    Lubricate the receptacle portion of the elbow connector and the mating bushing with the lubricant supplied. IMPORTANT: LUBRICATE ONLY IF THE TRANSFORMER AND ELBOW ARE KNOWN TO BE DE-ENERGIZED. Operate the connection per the operating instructions using a full insulated hotstick type tool; DO NOT OPERATE BY HAND.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.