ABB - Installation Products 168FLR3B0270 - Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 4/0 AWG Stranded/Compressed.

ABB Installation Products 168FLR3B0270 Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port…

UPC: 783786503766


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 168FLR3B0270 molded current limiting fuse housing provides reliable overcurrent protection for medium-voltage systems rated at 8.3kV. Designed for installations requiring precise fault isolation, this housing accommodates cable insulation diameters from 0.635 inch (16mm) to 0.905 inch (23mm) and supports 4/0 AWG stranded/compressed aluminum conductors. The large housing design ensures compatibility with high fault current scenarios while maintaining structural integrity. Two capacitive test ports enable safe diagnostic testing without system de-energization, reducing downtime during maintenance or fault analysis. The molded construction delivers consistent dielectric performance and environmental resistance, making it suitable for indoor and outdoor applications in power distribution, industrial facilities, and utility substations. Compliance with medium-voltage safety standards ensures reliable operation in critical infrastructure.
  • Rated for 8.3kV nominal fuse voltage
  • Accommodates 16-23mm cable insulation diameters
  • Supports 4/0 AWG stranded/compressed aluminum conductors
  • Two capacitive test ports for safe diagnostics
  • Molded construction for environmental resistance

Specifications

Amperage Rating
200 A
Application
Protect Light Duty Underground Distribution Systems
Color
Black
Conductor Range
4/0 STR/COMPR AWG , 250 kcmil
Insulation
True
Length
21.12 in
Length
536.448 mm
Material
EPDM-Rubber
Special Features
Full-Range Current-Limiting Fusing with 50kA Interrupting Capability. Hotstick Operable 15kV Loadbreak Elbow Switching
Standard
IEEE 386, ANSI C37.40, ANSI C37.41, ANSI C37.47
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Fused Elbow Connector
Voltage Rating
8.3 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 4/0 AWG Stranded/Compressed.

168FLR3-D0270

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 4/0 AWG Stranded/Compressed.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid/Compact.

168FLR3A0220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.575 inch - 0.740 inch / 15-19mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Direct Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid/Compact.

274AFLR1-C0230

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Direct Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Bi-Metal Conductor size 3/0 AWG Stranded/Compressed, 4/0 AWG Solid/Compact.

168FLR3-C5260

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Bi-Metal Conductor size 3/0 AWG Stranded/Compressed, 4/0 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2/0 AWG Stranded Compressed, 3/0 AWG Solid Compact

274FLR1-B0250

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2/0 AWG Stranded Compressed, 3/0 AWG Solid Compact
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 4/0 AWG Stranded/Compressed.

168FLR3-C0270

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 4/0 AWG Stranded/Compressed.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 1 AWG Stranded/Compressed, 1/0 AWG Solid/Compact.

168FLR3-C0230

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 1 AWG Stranded/Compressed, 1/0 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid Compact

274FLR1-D0220

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid Compact

Frequently Asked Questions

What standards does the Elastimold 168FLR Fused Elbow meet?

The Elastimold 168FLR Fused Elbow meets applicable portions of IEEE 386, ANSI C37.40, ANSI C37.41, and ANSI C37.47 standards.

How do I select the correct housing size for the 168FLR?

Select the housing size based on the desired fuse. Size 1 is for 3-45A 8.3kV and 6-20A 15.5kV fuses, while Size 3 is for 65-80A 8.3kV and 3-45A 17.2kV fuses.

What items are included in the 168FLR Fused Elbow kit?

Each kit contains one elbow connector housing, one crimp connector, one probe lug, four tubes of lubricant, installation instructions, and a crimp chart.

What types of conductors are compatible with the compression lugs?

Copper compression lugs are suitable for all copper conductors. Bi-metal compression lugs with universal aluminum barrels are suitable for both copper or aluminum conductors.

What are the key features of the 168FLR Fused Elbow?

Key features include full-range current-limiting fusing, hotstick operable 15kV loadbreak switching, a fully sealed and submersible design, and built-in voltage test points. It also has a split center section for easy fuse replacement.

What is the current rating range for the 168FLR Fused Elbow?

The current rating for the 168FLR Fused Elbow ranges from 3 to 80 Amps. It also has a symmetrical interrupting capability of 50,000 Amps.

What voltage class is the 168FLR Fused Elbow designed for?

The 168FLR Fused Elbow is designed for a 15kV voltage class, with an 8.3kV nominal fuse voltage and a 10kV maximum rated fuse voltage.

What is the primary application of the 168FLR Fused Elbow?

The 168FLR combines full-range current-limiting fusing with 15kV hot stick operable, loadbreak elbow switching to improve distribution system reliability. It protects light duty underground distribution systems like sub-loops and radial taps.

What items are included in the 168FLR Fused Elbow kit?

Each kit contains one elbow connector housing, one crimp connector, one probe lug, four tubes of lubricant, installation instructions, and a crimp chart.

What standards does the Elastimold 168FLR Fused Elbow meet?

The Elastimold 168FLR Fused Elbow meets applicable portions of IEEE 386, ANSI C37.40, ANSI C37.41, and ANSI C37.47 standards.

How to Install the 168FLR/274FLR Loadbreak Fused Elbow Connector

This guide provides step-by-step instructions for the safe and proper installation of the 168FLR or 274FLR Loadbreak Fused Elbow Connector, including cable preparation, assembly, and neutral connection. Ensure all apparatus are de-energized before beginning.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Wire brush, Crimp tool, Torque-limiting Allen Wrench (supplied), Probe Wrench (supplied), Hotstick (for final connection)

Supplies needed:

168FLR or 274FLR Loadbreak Fused Elbow Connector kit, UD cable, No. 14 AWG / 2.5mm copper wire, Grounding connector, Lubricant (supplied in kit), Optional 200ECS Cold Shrink Cable Seal

  1. Perform Pre-Installation Checks and Safety

    DANGER: All apparatus must be de-energized during installation. Do not touch or move energized products. This product should be installed only by competent personnel trained in high voltage electrical equipment. Inspect all parts for damage, rating, and compatibility. Check contents for completeness. Verify proper fit with cable and/or mating products. Thread the probe into the compression lug to check threads; replace if resistance is encountered. Read all instructions before starting and maintain cleanliness.

  2. Train the Cable

    Using the bushing centerline as reference, cut excess cable off 20 inches minimum beyond the bushing. Slide the optional 200ECS Cold Shrink Cable Seal onto the cable. Remove the jacket from the excess cable length and an additional distance of 'A' (11-1/2” for FLR-1, 15-3/4” for FLR-3) plus 7-3/8” from the bushing centerline. If using a Cable Seal kit, follow its instructions; otherwise, unwrap and fold the concentric neutral wires back over the jacket and bind them. Squarely cut off the cable a distance of 'A' from the bushing centerline, leaving 7-3/8” minimum of cable to terminate.

  3. Prepare the Cable End

    Cut 1-1/8” from the cable end, ensuring a square cut and taking care not to nick the conductor. Wire brush the bare aluminum conductors and immediately install the compression lug. Rotate the lug to spread the inhibitor. Crimp the unthreaded end of the compression lug to the conductor, referring to the crimp chart provided with the lug. Start the crimp at the crimp line mark and rotate 180 degrees for each successive crimp. Carefully wipe any excess inhibitor from the outside of the lug and cable. Remove the insulation shield 5-1/2” from the end of the lug and bevel the insulation end 1/8” maximum. Thoroughly clean the insulation to remove all traces of conductive residue.

  4. Assemble Cable Half Housing and Fuse

    Apply the supplied lubricant to the outside of the connector, cable insulation, conductive shield, and the cable half of the Fused Elbow cable entrance end. DO NOT SUBSTITUTE lubricant. Insert the connector and cable into the cable half of the Fused Elbow until the top end of the connector protrudes beyond surface 'A'. Insert the threaded terminal end of the fuse into the cable half of the Fused Elbow and thread it into the cable connector. HAND TIGHTEN the fuse. CAUTION: The fuse stud will fracture if over torqued. Pull the housing up against the bottom of the tightened fuse.

  5. Install the Probe Connector

    Assemble the probe connector to the fuse terminal. Rotate the probe connector so that its flats are perpendicular to the bushing with which it will mate. Lock the probe connector in position and tighten the setscrews using the special torque-limiting Allen wrench supplied in the fuse kit. Rotate the cable half of the Fused Elbow so that the test point is perpendicular to the flats on the probe connector.

  6. Assemble Elbow Half Housing and Probe

    Apply lubricant to the elbow half of the fused elbow and assemble it to the cable half. The cuff of the cable half will overlap the elbow half by 3/4”. Ensure that the probe connector faces the opening of the fused elbow half and that the two test points are in line with each other. Insert the probe into the probe connector; it may be necessary to push on the cable to align the probe with the fuse. Start the threads by hand, taking care not to cross-thread the probe. To tighten, use the special torque-limiting Allen wrench supplied by inserting the short end into the hole in the probe and tightening until the wrench bends and remains bent. Position the hose clamp as shown in the diagram and tighten it. DO NOT OVERTIGHTEN.

  7. Connect the Concentric Neutral

    Using a separate copper wire (No. 14 AWG / 2.5mm) or equivalent, insert one end through each grounding eye on the elbow housing and cable housings. Twist tightly, taking care not to damage the eyes. Finish installing the 200ECS jacket seal if used. Twist all neutral wires, exercising care not to damage the grounding eyes, and connect them to ground using an appropriate connector. Provide adequate slack in the wires for elbow operation.

  8. Prepare for Final Connection to Bushing Plug

    Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. LUBRICATE ONLY IF THE TRANSFORMER AND ELBOW ARE KNOWN TO BE DE-ENERGIZED. The elbow is now ready for operation; DO NOT OPERATE BY HAND. Use a full insulated hotstick type tool for connection.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.