Overview
- 28kV voltage rating
- 200 Amp current rating
- Jacket seal for environmental protection
- Integrated test point for diagnostics
- Bi-metal compression lug included
Specifications
Amperage Rating | 200 A |
Application | 28 kV, 200 Amp |
Color | Black |
Conductor Range | #3 STR/COMPR AWG , #2 SOL/COMPT AWG |
Connection | Compression |
Connection Type | Loadbreak Jacket Seal Elbow Connector with Test Point |
Current Rating | 200 A |
Environmental Conditions | All Weather Conditions |
Insulation | True |
Length | 11.47 in |
Length | 291.338 mm |
Material | Housing - EPDM-Rubber |
Material | Bi-Metal Compression Lug |
Series | 262LRJS |
Size | 0.635 inch - 0.905 Inch Cable Insulation Diameter, #3 Stranded/Compressed or #2 Compact/Solid Wire Size |
Special Features | 28kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard. Built in cable jacket seal. Non-corrosive capacitive test point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector with Test Point and Jacket Seal |
Voltage Rating | 28 kV |
Voltage Rating | 28kV |
Width | 8.2 in |
Width | 208.28 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 2.4100 L |
Package Weight (Metric) | 1.0930 kg |

262LR-C5210
25kV 200 Amp, Loadbreak Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #3 Stranded Wire Size, Bi-Metal Compression Lug.
K675LR-M-2400
900 Amp, 15/25KV, DeadBreak, Copper, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 900 /Compacted Solid 1000 /mmSquared Compact 500.
K656ETP-K0330-DRG
600 Amp, Test and Ground Connector Kit, 25KV, Capacitive Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 500 /Compacted Solid 600 /mmSquared Compact 250/300.
K675LR-J5300
900 Amp, 15/25KV, DeadBreak, Copper, Elbow with Insulated Plug, Cap, Stud, Lug and Cable Adapter, Cable Insulation Diameter 0.980 inch to 1.180 inch. Bi-Metal Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185.
K676LR-N2380
900 Amp, Elbow Connector, with Test Point, with Insulated Plug, Cap, Stud, Lug and Cable Adapter, 15/25KV, Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed/Stranded 700/750 or Compacted/Solid 900.
K655L2-M0380-S
600 Amp, 2 Way L Kit, DeadBreak, 15/25KV, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. Cold-Shrinkable Jacket Seal Included.
K656ETP-K0300-DRG
600 Amp, Test and Ground Connector Kit, 25KV, Capacitive Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185.Frequently Asked Questions
Is the loadbreak elbow ANSI certified?
Yes, the enhanced loadbreak elbow has ANSI certification.
What industry standards does the elbow comply with?
The enhanced loadbreak elbow is IEEE 386 compliant.
Does the elbow prevent sticking with bushings?
Yes, it features a no-stick interface when used with Elastimold bushings, which has been NEETRAC tested.
Is the loadbreak elbow approved for rural infrastructure?
Yes, it has Rural Utilities Service (RUS) acceptance from the USDA, authorizing its use in rural infrastructure construction.
What is the current rating and voltage range of the elbow?
The enhanced loadbreak elbow is rated for 200 amps and is available for 15 kV and 25 kV systems.
Is the loadbreak elbow ANSI certified?
Yes, the enhanced loadbreak elbow has ANSI certification.
What industry standards does the elbow comply with?
The enhanced loadbreak elbow is IEEE 386 compliant.
Does the elbow prevent sticking with bushings?
Yes, it features a no-stick interface when used with Elastimold bushings, which has been NEETRAC tested.
Is the loadbreak elbow approved for rural infrastructure?
Yes, it has Rural Utilities Service (RUS) acceptance from the USDA, authorizing its use in rural infrastructure construction.
What is the current rating and voltage range of the elbow?
The enhanced loadbreak elbow is rated for 200 amps and is available for 15 kV and 25 kV systems.
How to Install 261LRJS and 262LRJS Loadbreak Elbow Connectors
This guide provides step-by-step instructions for the safe installation and assembly of 261LRJS (without test point) and 262LRJS (with test point) Loadbreak Elbow Connectors with Jacket Seal on UD cable.
Estimated time: 1h 30m
Tools needed:
Probe wrench, Crimp tool (refer to lug packaging), Wire brush, Wire strippers, Hotstick (for energized operation)
Supplies needed:
261LRJS or 262LRJS Elbow Connector Kit (housing, compression lug, probe), Lubricant (supplied, do not substitute), 3 Sealing strips (mastic), UD cable with jacketed concentric neutral wires, Vinyl tape, No. 14 AWG / 2.5mm copper wire (or equivalent), Appropriate connector for neutral to ground, HV insulated cap(s) or connector(s) (if replacing shipping covers)
- Initial Safety and Component Inspection
DANGER: Ensure all apparatus is de-energized before beginning installation. Inspect all components for damage, proper rating, and compatibility with the cable and mating parts. Check the contents of the package to ensure completeness. Thread the probe into the compression lug to check for resistance; replace damaged components if resistance is encountered.
- Cable Training
Train the UD cable to ensure sufficient slack for ease of future operation. Pull extra cable 24-26 inches beyond the bushing centerline and mark this point. Remove the outer jacket 7-3/4 to 8 inches back from the tape mark. Unwrap the neutral wires past the bushing centerline. Cut the excess cable squarely at the bushing centerline.
- Apply Mastic and Tape
Wrap one strip of mastic, stretching slightly, around the cable jacket. Bend all neutral wires straight back over the mastic and along the cable, pressing them into the mastic. Wrap a second strip of mastic completely around the outer jacket, overlapping the imbedded neutral wires. Use a third strip if needed to build up the diameter. Cover all mastic with vinyl tape.
- Prepare Insulation and Install Compression Lug
Remove the insulation shield and insulation from the cable end, cutting squarely without nicking the conductor. Wire brush bare aluminum conductors and immediately install the compression lug, rotating it to spread inhibitor. Position the lug so the contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe off any excessive inhibitor. Remove the insulation shield as shown in the diagram and bevel the insulation end by 1/8 inch maximum. Thoroughly clean the insulation to remove all traces of conductive residue.
- Elbow Assembly
Lubricate the cable insulation and the inside of the elbow housing using only the supplied lubricant; do not substitute. Slide the elbow connector onto the cable using a back-and-forth twisting motion, then wipe off all excess lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring not to cross-thread. The probe should turn freely for approximately four turns before becoming snug. Tighten the probe with the probe wrench until the wrench bends, indicating proper torque.
- Concentric Neutral Connection
Insert one end of a separate copper wire (No. 14 AWG / 2.5mm or equivalent) through the grounding eye on the elbow and twist it tightly, taking care not to damage the eye. Pull the hood over the concentric neutral seal area on the cable by pulling the tabs or rolling the seal down. Twist all neutral wires together and connect them to ground using an appropriate connector, ensuring to provide adequate slack in the wires for future elbow operation.
- Final Lubrication for Connection (Pre-Operation)
DANGER: Lubricate the receptacle portion of the elbow connector and the mating bushing ONLY if the transformer and elbow are known to be de-energized. Do not operate the elbow by hand; use a full insulated hotstick as per operating instructions.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.