Authorized ABB Distributor (Installation Products)
ABB - Installation Products K655L2-M0380-S - 600 Amp, 2 Way L Kit, DeadBreak, 15/25KV, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900. Cold-Shrinkable Jacket Seal Included.

ABB Installation Products K655L2-M0380-S 600 Amp, 2 Way L Kit, DeadBreak, 15/25KV, Cable Insulation Diameter 1.370 inch to 1.630…

UPC: 783786421718


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K655L2-M0380-S is a 600 Amp, 2-way deadbreak L kit designed for 15/25KV medium-voltage cable systems. This kit accommodates cable insulation diameters from 1.370 inch to 1.630 inch and features aluminum compression lugs for secure conductor termination. Compatible with compressed stranded conductors sized 700/750 kcmil or compacted solid conductors up to 900 kcmil, it provides reliable performance in industrial and utility applications. The cold-shrinkable jacket seal ensures a moisture-resistant, long-lasting connection, reducing installation time and eliminating the need for heat-shrink or tape applications. Ideal for underground distribution, switchgear interconnections, and renewable energy projects where high current capacity and durability are critical. The deadbreak design allows for safe, load-break operations without de-energizing the system, enhancing operational flexibility. Manufactured by ABB Installation Products, this kit meets stringent electrical and mechanical standards for medium-voltage cable accessories.
  • 600 Amp rated for high-current medium-voltage applications
  • 2-way deadbreak design enables safe load-break operations
  • Compatible with 15/25KV cable insulation diameters 1.370–1.630 inch
  • Supports compressed stranded 700/750 kcmil or compacted solid 900 kcmil conductors
  • Includes cold-shrinkable jacket seal for moisture-resistant, permanent installation

Specifications

Amperage Rating
600 A
Application
Used to connect two cable ends and using the two insulating plugs as test points allows for capacitive voltage testing
Color
Black
Conductor Range
700 to 750 kcmil , 900 kcmil
Connection
Compression
Current Rating
600 A
Environmental Conditions
Fully Submersible
Insulation
True
Length
10.87 in
Length
276.098 mm
Material
Aluminum
Material
Housing - EPDM-Rubber
Series
K655L2
Size
Cable Insulation Diameter 1.370 inch to 1.630 inch
Special Features
Cold-Shrinkable Jacket Seal
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak 2-Way L Kit
Voltage Rating
15 to 25 kV
Voltage Rating
15/25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
14.0000 L
Package Weight (Metric)
6.3500 kg
600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Test and Ground Connector Kit, Insulated Cap. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size Compressed Stranded 700/750 kcmil or Compacted Solid 900 kcmil.

656ETP-M0380-DRG

600 Series Elbows with IEEE 386 Capacitive Test Points, 600 Amp, 15kV, Test and Ground Connector Kit, Insulated Cap. Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size Compressed Stranded 700/750 kcmil or Compacted Solid 900 kcmil.
Single cable clamp 150-300mm2 for power terminal type 5

45000034

Single cable clamp 150-300mm2 for power terminal type 5
600 Amp, Test and Ground Connector Kit, 25KV, Capacitive Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185.

K656ETP-K0300-DRG

600 Amp, Test and Ground Connector Kit, 25KV, Capacitive Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185.
600 Amp, Test and Ground Connector Kit, 25KV, Capacitive Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

K656ETP-K0270

600 Amp, Test and Ground Connector Kit, 25KV, Capacitive Test Point, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
600 Amp, DeadBreak Elbow Connector, 2-Way L Kit, 35KV, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. Cold-Shrinkable Jacket Seal Included.

755L2-K0250-S

600 Amp, DeadBreak Elbow Connector, 2-Way L Kit, 35KV, Cable Insulation Diameter 1.090 inch to 1.310 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 2/0 /Solid 3/0 /mmSquared 67.43. Cold-Shrinkable Jacket Seal Included.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2/0 AWG Stranded/Compressed, 3/0 AWG Solid/Compact.

168FLR3B0250

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2/0 AWG Stranded/Compressed, 3/0 AWG Solid/Compact.
600 Amp, Dead Break, Elbow Connector, Cam-Op Connector Kit, 15KV, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

655LINKCLRJ0270BDRG

600 Amp, Dead Break, Elbow Connector, Cam-Op Connector Kit, 15KV, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
600 Amp, DeadBreak Elbow Connector, 2-Way L Kit, 35KV, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185. Cold-Shrinkable Jacket Seal Included.

755L2-M0300-S

600 Amp, DeadBreak Elbow Connector, 2-Way L Kit, 35KV, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185. Cold-Shrinkable Jacket Seal Included.

Frequently Asked Questions

What cable insulation diameter range does this kit support?

The K655L2-M0380-S supports cable insulation diameters from 1.370 inch to 1.630 inch.

What is the voltage rating of this deadbreak kit?

The K655L2-M0380-S is rated for 15/25KV medium-voltage applications.

What conductor sizes are compatible with this kit?

The kit accommodates compressed stranded conductors sized 700/750 kcmil or compacted solid conductors up to 900 kcmil.

What material are the compression lugs made of?

The compression lugs are made of aluminum for reliable conductivity and durability.

Does this kit include a jacket seal?

Yes, a cold-shrinkable jacket seal is included for moisture-resistant installation.

Is this kit suitable for load-break operations?

Yes, the deadbreak design allows for safe load-break operations without de-energizing the system.

How to Install the 600/900 Series Deadbreak Connecting Plug

This guide provides step-by-step instructions for installing the 600/900 series deadbreak connecting plug, designed for power distribution systems. It covers stud installation, lubrication, connection, and grounding. WARNING: All apparatus must be de-energized during installation. Installation should only be performed by competent personnel.

Estimated time: 30m

Tools needed:

3/8 inch hex bit socket, Torque wrench, 600ATM

Supplies needed:

Connecting Plug, Lubricant (supplied), No. 14 AWG (2.5mm) copper wire

  1. Install the Stud into the Mating Plug Device

    If the mating plug device is not equipped with a stud, hand tighten the stud into the mating plug device. Thread the stud until the start of the flats are below the contact surface.

  2. Clean and Lubricate Connecting Plug and Mating Part

    Clean both the connecting plug and its mating part as indicated. Lubricate both parts with the supplied lubricant. DO NOT SUBSTITUTE other lubricants, as they may be harmful. Ensure surfaces remain clean.

  3. Connect and Torque the Connecting Plug

    Push the connecting plug into the elbow, bushing extender, vault stretcher, or elbow end module, and engage the threads. Hold the contact of the connecting plug against the contact surface of the mating part. Using a 600ATM or a 3/8” hex bit socket and a torque wrench, tighten the connection to 50 to 60 foot-pounds (68 to 81 newton-meters) of torque.

  4. Ground the Connecting Plug (If Applicable)

    If applicable, insert one end of a No. 14 AWG (2.5mm) copper wire or equivalent through the grounding eye on the connecting plug. Twist the wire tightly, taking care not to damage the eye. Connect the other end of the wire to ground.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.