- Rated for 25kV, 200 Amps medium voltage applications
- Bi-metal conductor compatible with 2/0 stranded/compressed and 3/0 solid/compact cables
- Accommodates cable insulation diameters from 1.090 to 1.310 inches (27.69-33.27 mm)
- Integrated test point for safe circuit testing without de-energizing
- Kit includes elbow housing, compression lug, probe, wrench, lubricant, and installation instructions
Specifications
Amperage Rating | 200 A |
Application | 25/28kV, 200 Amp, Loadbreak Connector |
Color | Black |
Conductor Range | 2/0 STR/COMPR AWG , 3/0 SOL/COMPT AWG |
Connection | Push-In |
Connection Type | Compression Lug |
Current Rating | 200 A |
Environmental Conditions | All Weather Conditions |
Insulation | True |
Material | Bi-Metal |
Material | Housing - EPDM-Rubber |
Series | Loadbreak Elbow |
Series | 262LR |
Size | 1.090"-1.310" (27.69-33.27 mm) |
Size | Cable Insulation Diameter 1.090-1.310 inches (27.69-33.27 mm) |
Size | 8.20 inch (208.3 mm) X 9.03 inch (229.4 mm), 2.86 inch (72.6 mm) Diameter |
Special Features | 15kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard. Non-corrosive capacitive test point |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Elbow Connector with Test Point |
Voltage Rating | 25 to 28 kV |
Voltage Rating | 25 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

262LRJS-B5250
25kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .635 inch - .905 Inch Cable Insulation Diameter, 2/0 Stranded/Compressed or 3/0 Compact/Solid Wire Size, Bi-Metal Compression Lug.
755LR-M0280
600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.370 inch to 1.630 inch. Universal Aluminum Compression Lug. Conductor Size AWG or kcmil Compressed Stranded 250, Solid 350.
161LR-C5270-S
15kV, 200 Amp Loadbreak Elbow Connector without Test Point. Cable Insulation Diameter 0.805 - 1.060 inches. Bi-Metal Conductor. Conductor Size 270 - 4/0 Stranded/Compressed or 250 kcmil Sold/Compact. S - Cold-Shrinkable Jacket Seal. Length 9.03 inches, 7.44 inch Width (without counting Probe). 2.92 Diameter.
K655LRTP-G0220-DRG
600 Amp, 25kV, Stick-Op Connector Kit with Insulated Cap. Aluminum Compression Lug. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size AWG or kcmil, Compressed Stranded #2/Compacted Solid #1/mmSquared Compact 35.
676LRTP-K2330-DRG
900 Amp, 15kV Stickop Connector Kit With Test Point, No Sealing Kit. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size Compressed Stranded 500 kcmil or Compacted Solid 600 kcmil or mmSquared Compact 250/300 kcmil. Copper Conductor Only.
K656LRTP-LM0270DRG-S
600 Amp, 25kV, Deadbreak, Stick-Op Connector Kit with Test Point, Cable Insulation Diameter 1.280 inch to 1.430 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 4/0 /Compacted Solid 250 /mmSquared Compact 125. With Insulated Cap. Cold-Shrinkable Jacket Seal Included.
655LRTP-G0230-DRG
600 Amp, 15kV, Deadbreak Stick-Op Connector Kit, With Insulated Cap. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded #1 /Compacted Solid 1/0 /mmSquared Compact 70.Frequently Asked Questions
What is the maximum operating voltage for this elbow connector?
The ABB 262LR-E5250 loadbreak elbow connector is designed for 25kV applications.
What conductor sizes can this elbow connector accommodate?
This elbow connector is suitable for 2/0 Stranded/Compressed and 3/0 Solid/Compact conductor sizes.
What is the range of cable insulation diameters supported?
The connector supports cable insulation diameters from 1.090 to 1.310 inches (27.69-33.27 mm).
Does the kit include a test point?
Yes, the 262LR-E5250 kit includes a test point for safe circuit testing.
What components are included in the 262LR-E5250 kit?
The kit contains the elbow connector housing, compression lug, probe, probe wrench, lubricant, and installation instructions.
How to Install 261LR/262LR Loadbreak Elbow Connectors
This guide provides step-by-step instructions for the safe and proper installation of 261LR (without test point) and 262LR (with test point) Loadbreak Elbow Connectors. These connectors are designed to terminate various UD cables and connect to 25kV class 200ampere loadbreak bushings.
Estimated time: 1h 30m
Tools needed:
Probe Wrench, Wire brush, Crimp tool, Hotstick (for operation)
Supplies needed:
Elbow Connector Housing, Compression Lug, Probe, Lubricant (Do Not Substitute), Copper wire (No. 14 AWG / 2.5mm) or equivalent, Appropriate connector (for neutral wires), Vinyl tape (if applicable for cable type), Conductive copper tape (if applicable for cable type), Cold shrink tube (if using sealing kits)
- Perform Pre-Installation Checks and Safety Procedures
DANGER: Ensure all apparatus is de-energized during installation or removal of parts, except for test point caps and indicators. Do not touch or move energized products. This product must be installed only by competent personnel trained in high voltage electrical safety practices. Inspect all package contents for completeness and damage. Verify all components fit properly with the cable and mating products. Check probe threads by hand-threading into the compression lug; replace damaged components if resistance is encountered. Read the entire installation instructions thoroughly before beginning and have all required tools ready, maintaining cleanliness.
- Prepare the Cable for Termination
Train the cable to ensure sufficient slack for future operation. Cut the cable squarely at the centerline of the bushing. Remove the outer jacket and/or copper tape shield according to your specific cable type (concentric neutral, drain wires, or copper tape shield) and the dimensions specified in the documentation (e.g., 9-5/8” (240mm) for jacket removal, 7-1/8” (180mm) for copper tape shield removal). Prepare neutral or drain wires as instructed for grounding. If using a cold shrink sealing kit, slide the cold shrink tube onto the cable, loose end first.
- Prepare Cable End and Install Compression Lug
Remove the shield and insulation 2-1/8” (55mm) from the cable end, ensuring a square cut without nicking the conductor. Wire brush bare aluminum conductors immediately and install the compression lug. Rotate the lug to spread inhibitor. Position the lug so its contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe excess inhibitor from the lug and cable. Remove the insulation shield as per the cable cut back template, ensuring a straight, smooth, and squared cut. Bevel the insulation end a maximum of 1/8” (5mm). Thoroughly clean the insulation to remove all traces of dirt or excess inhibitor.
- Assemble the Elbow Connector
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant. DO NOT SUBSTITUTE. Keep the insulation clean. Slide the elbow connector onto the cable using a back-and-forth twisting motion. Wipe off all excess lubricant. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends.
- Ground the Elbow and Neutral Wires
Insert one end of a separate copper wire (No. 14 AWG / 2.5mm) or equivalent through the grounding eye on the elbow. Twist tightly, ensuring not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Provide adequate slack in the wires for elbow operation. If using a cold shrink grounding kit, follow the instructions provided with that kit.
- Connect the Elbow to the Bushing Plug
WARNING: CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED before proceeding with the connection. Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. Only lubricate if known to be de-energized. Operate the connection using a full insulated 'hotstick' type live-line tool. DO NOT OPERATE BY HAND. Maintain positive control and use a fast, firm, straight motion to fully engage the elbow with the bushing, ensuring the internal lock engages.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.