Authorized ABB Distributor (Installation Products)
ABB - Installation Products K656LR-N0380 - 15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size Compressed/Stranded 700/750 or Compact/Solid 900.

ABB Installation Products K656LR-N0380 15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud…

UPC: 783786197521


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB K656LR-N0380 is a 15/25kV 600 Amp Series Deadbreak Elbow with Test Point, engineered for safe, load-interruption-free terminations in utility, industrial, and renewable energy applications. This fully shielded, dead-front connector features a molded rubber housing with 100% peroxide-cured EPDM insulation and conductive materials for long-term reliability in submersible environments. The integrated test point enables safe voltage verification without system de-energization, eliminating downtime during maintenance or troubleshooting. The aluminum compression lug supports conductor sizes of 700/750 compressed/stranded or 900 compact/solid, with cable insulation diameters ranging from 1.515" to 1.780". Typical applications include underground distribution, switchgear, transformers, and pad-mounted equipment. The compact, durable design withstands high humidity, temperature fluctuations, and corrosive environments, making it ideal for harsh operating conditions. Compatible with standard 600A bushings and requiring no specialized tools, the K656LR-N0380 delivers reliable performance in high-voltage electrical systems.
  • 15/25kV voltage class with 600 Amp continuous rating
  • Integrated test point for safe voltage verification without de-energization
  • Aluminum compression lug supports 700/750 compressed/stranded or 900 compact/solid conductors
  • Cable insulation diameter range: 1.515" to 1.780"
  • Fully shielded, dead-front molded rubber housing for submersible applications
  • Compatible with standard 600A bushings; no specialized tools required
  • Meets ANSI/IEEE Standard 386 for safety and reliability

Specifications

Amperage Rating
600 A
Application
15/25kV, 600 Amp Deadbreak Elbow Connection
Color
Black
Conductor Range
700 to 750 kcmil , 900 kcmil
Connection Type
Compression
Connection Type
Compression Lug
Current Rating
600 A
Environmental Conditions
Fully Submersible
Insulation
True
Length
13 in
Length
330.2 mm
Material
Aluminum
Material
Aluminum, Poly
Material
Housing - EPDM-Rubber
Series
600 Series Deadbreak Elbow
Series
K656LR
Size
Cable Insulation Diameter 1.515 inch to 1.780 inch
Special Features
Fully Shielded, Fully Submersible Molded Rubber Housing. 100 percent Peroxide-Cured Construction includes Insulation and Conductive EPDM Materials. Can be Easily Connected or Disconnected using Standard Hand Tools and Equipment in a De-Energized State. Non-Corrosive, Capacitive Test Point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Deadbreak Elbow Connector with Test Point
Voltage Rating
25 kV
Voltage Rating
15/25 kV
Width
10.36 in
Width
263.144 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
6.6200 L
Package Weight (Metric)
3.0030 kg
600 Amp, 25kV, Stick-Op Connector Kit. Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.

K655LRTP-N0380

600 Amp, 25kV, Stick-Op Connector Kit. Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size AWG or kcmil, Compressed Stranded 700/750 /Compacted Solid 900.
Single cable clamp 150-300mm2 for power terminal type 5

45000034

Single cable clamp 150-300mm2 for power terminal type 5
25 kV, 600 Amp, Deadbreak, Elbow Kit, with Test Point, Insulated Plug, Cap, Stud, Bi-Metal Lug, and Cable Adapter. Cable Insulation Diameter .760-.950. Conductor Size 1/0 Stranded/Compressed or 2/0 Compact/Solid

K656LR-G5240

25 kV, 600 Amp, Deadbreak, Elbow Kit, with Test Point, Insulated Plug, Cap, Stud, Bi-Metal Lug, and Cable Adapter. Cable Insulation Diameter .760-.950. Conductor Size 1/0 Stranded/Compressed or 2/0 Compact/Solid
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.

K656LR-M0330

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.370 inch to 1.630 inch. Conductor Size Compressed/Stranded 500 or Compact/Solid 600 or mm2 Compact 250/300.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size Compressed/Stranded 650 or Compact/Solid 750 or mm2 Compact 400.

K656LR-N0360

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size Compressed/Stranded 650 or Compact/Solid 750 or mm2 Compact 400.
15/25kV, 600 Amp, Elbow with Sealing Kit, With Test Point (includes Insulating Plug, Stud, Lug and Cable Adapter), Cable Insulation Diameter .640-.820 inches, Aluminum Lug, Conductor Size #2 Stranded/Compressed or #1 Compact/Solid

K656LR-F0220-SG3

15/25kV, 600 Amp, Elbow with Sealing Kit, With Test Point (includes Insulating Plug, Stud, Lug and Cable Adapter), Cable Insulation Diameter .640-.820 inches, Aluminum Lug, Conductor Size #2 Stranded/Compressed or #1 Compact/Solid
25kV, 600 Amp, Deadbreak Elbow, No Sealing Kit, without Test Point, Cable Insulation 1.370-1.630 inches, Bi-Metal Lug, Conductor Size kcmil Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185.

K655LR-M5300

25kV, 600 Amp, Deadbreak Elbow, No Sealing Kit, without Test Point, Cable Insulation 1.370-1.630 inches, Bi-Metal Lug, Conductor Size kcmil Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185.
15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

K656LR-N0300-SG3

15/25kV 600 Amp Series Deadbreak Elbow with Test Point (with Insulated Plug, Cap, Stud, Lug and Cable Adapter), Aluminum Compression Lug. Cable Insulation Diameter 1.515 inch to 1.780 inch. Conductor Size Compressed/Stranded 350 or Compact/Solid 400 or mm2 Compact 185. Cold Shrinkable Seal with Copper Braid and Constant Force Spring Included.

Frequently Asked Questions

What is the maximum operating voltage for the K656LR elbow connector?

For the 15kV voltage class, the maximum operating voltage is 8.3kV phase-to-ground and 14.4kV phase-to-phase. For the 28kV voltage class, it is 16.2kV phase-to-ground and 28kV phase-to-phase.

What conductor sizes can the K656LR handle?

The K656LR can be used with conductor sizes ranging from #2 AWG to 1250 kcmil for both aluminum and copper conductors.

What is the insulation diameter range for the K656LR?

The K656LR is designed for insulation diameters ranging from 0.640 inches to 1.935 inches.

What standards does the K656LR meet?

The K656LR meets ANSI/IEEE Standard 386, Latest Revision.

What is the continuous current rating of the K656LR?

The K656LR has a continuous current rating of 600 Amps.

What is the momentary current rating for the K656LR?

The K656LR has a momentary current rating of 25kA Sym for 10 Cycles.

What is the impulse withstand rating for the K656LR?

For the 15kV class, it's 95kV BIL. For the 28kV class, it's 140kV BIL.

What is the AC one-minute withstand voltage for the K656LR?

For the 15kV class, it's 34kV AC. For the 28kV class, it's 45kV AC.

What is the DC fifteen-minute withstand voltage for the K656LR?

For the 15kV class, it's 53kV DC. For the 28kV class, it's 84kV DC.

What is the corona extinction sensitivity for the K656LR?

For the 15kV class, it's 11kV AC @ 3pC sensitivity. For the 28kV class, it's 21.5kV AC @ 3pC sensitivity.

How to Install K655/K675LR Deadbreak Elbow Connectors

This guide provides step-by-step instructions for the safe and proper installation of K655/K675LR Deadbreak Elbow Connectors, including cable preparation, component assembly, and grounding procedures.

Estimated time: 1h 30m

Tools needed:

Wire brush, Hotstick, Suitable voltage sensing device, Crimping tool, Wire strippers

Supplies needed:

Lubricant, Compression lug, Threaded stud, Insulating plug (if applicable), Tape marker, No. 14 AWG Copper wire (or equivalent), Suitable grounding connector, Silicone lubricant

  1. Initial Safety and Inspection

    Ensure all apparatus is de-energized before beginning installation. Do not touch or move energized products. This installation must be performed by competent personnel trained in high voltage electrical equipment safety. Inspect all package contents and components for completeness, damage, proper rating, and compatibility with mating parts.

  2. Prepare the Cable

    Assemble the cable in its final position with enough slack. For concentric neutral cable, unwind the neutral wires. Cut the cable 1-3/4” (45mm) from the centerline of the mating product. Clean the outer surface of the cable for a distance of 24” (610mm) or up to the bent back concentric neutral wires. Follow specific instructions for 20MA/21MA grounding devices, 600ECS Jacket Cable Seals, UNISHIELD*, LEAD SHEATH, JACKETED, or NON-JACKETED cables for outer jacket removal and shield preparation, including specific dimensions for insulation and semi-con shield.

  3. Install the Cable Adapter

    Bevel the end of the cable insulation at a 45-degree angle, approximately 1/4” (6mm) back. Thoroughly clean and then lubricate the cable insulation, working towards the semi-con shield. Install the cable adapter, small end first, until it is flush with the edge of the tape marker.

  4. Prepare the Conductor

    Remove any protruding cable insulation by cutting it even with the end of the cable adapter. Be careful not to cut or nick the cable adapter or the conductor. Verify that the length of the exposed conductor is between 4-1/4” and 4-9/16” (108mm-116mm). If the length is incorrect, redo the assembly.

  5. Crimp the Compression Lug

    For copper conductors, fully insert the conductor into the compression lug. For aluminum conductors, wire brush the conductor immediately before fully inserting it into the compression lug. Measure the 'Check Dimension' before crimping; it must be less than 6-3/8”. Crimp the compression lug according to the instructions supplied with the lug. After crimping, wipe off all excess inhibitor. The distance from the end of the compression lug to the cable adapter should be between 6-3/8” to 7-1/8” (162mm-181mm).

  6. Install the Elbow

    Lubricate the cable adapter and the inside of the elbow cable entrance. Install the elbow onto the cable adapter, pushing until it cannot advance further. Ensure the cable adapter remains flush with the tape marker; reposition if necessary. Remove the tape marker.

  7. Connect Mating Products

    WARNING: Do not connect or disconnect mating products while energized, and do not energize while disconnected. Remove protective caps from both the elbow and the mating part. If the mating part is not equipped with a stud, hand tighten the threaded stud (supplied with the elbow) into the mating part. Clean and lubricate both the elbow and the mating part with the supplied lubricant, ensuring all surfaces remain clean.

  8. Assemble the Elbow to Mating Part

    Push the elbow onto the mating part, carefully aligning the hole in the compression lug with the stud on the mating part. For the opposite end of the elbow, clean and lubricate the mating part, then insert it into the elbow. Engage the threads and hand tighten. Torque the mating part according to its specific instructions.

  9. Install Insulating Plug (Optional)

    If an insulating plug is used as a mating part, clean and lubricate the inner surface of the voltage detection cap. Place the cap onto the elbow and push down firmly until it snaps securely into place. Proceed to the voltage test directions.

  10. Ground the Cable Shield

    Insert one end of a wire (at least No. 14 AWG Copper equivalent ampacity) through the grounding eye and twist to form a small loop, taking care not to damage the eye. Connect this wire to ground using a suitable connector. The cable shield must be grounded; follow instructions supplied with any grounding device, or use an alternate grounding method. It is also recommended to waterproof the cable jacket at this point to prevent moisture ingress.

  11. Perform Voltage Test

    Remove the test point cap using a hotstick, peeling it off at an angle. WARNING: The voltage test point is a capacitance device, not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device designed for capacitive test points to determine if the cable is energized. Treat the elbow as energized until a 'no voltage' indication is confirmed by other means. After testing, clean and lubricate the inside surface of the cap with silicone lubricant and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.