ABB Installation Products 25PCJ1N1380 25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…
UPC: 783786645381
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Voltage Rating: 25 kV for medium-voltage applications
- Conductor Material: Aluminum, supporting 750 AWG stranded conductors
- Cable Insulation Diameter Range: 1.515" to 1.780"
- Housing Style: Single-piece design for simplified installation and robust protection
- Included Components: Housing, connector, lubricant tube, installation instructions, and crimp charts
Specifications
Application | For Direct Burial, Vault, Submersible and Other Severe Service Applications |
Color | Black |
Conductor Range | 750 kcmil |
Connection | Compression |
Insulation | Yes |
Material | EPDM Rubber |
Number Of Conductors | 2 |
Size | 15-3/4 inch long |
Special Features | Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable |
Standard | IEEE Standard 404 |
Type | Power Cable Joint |
Voltage Rating | 25 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 3.6000 L |
Package Weight (Metric) | 1.6330 kg |

25PCJ1N2380
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.515 inch to 1.780 inch. Copper Conductor. Conductor Size AWG Stranded 750.
25PCJ1M2330
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Stranded 500.
25PCJ1M2360
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 750.
35PCJ1M1300
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 350.
35PCJ1M1280-1270
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 250. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
25PCJ1M1360
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Solid 750.
35PCJ1M1310
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Solid 500.
35PCJ1M1330-S
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 500. Cold-Shrinkable Jacket Seal Included.Frequently Asked Questions
What are Elastimold PCJ power cable joints?
They are permanent, fully shielded, fully submersible splices with crimped connectors inside EPDM rubber housings. They are used for straight or transition splicing of power cables.
What is the overall length of a 25PCJ1GX joint?
The overall length (Dimension A) for a 25PCJ1GX joint is 14 3/8 inches.
Can aluminum connectors be used with copper cables?
Yes, aluminum compression connectors are suitable for splicing aluminum conductor to aluminum conductor or aluminum conductor to copper conductor.
What type of connector is needed for copper-to-copper splices?
An all-copper compression connector is required for copper-to-copper connections. Copper connectors should not be used on aluminum conductors.
What is the corona extinction voltage for a 35 kV joint?
For a 35 kV class joint, the corona extinction voltage with 3 pC sensitivity is 30 kV.
What is the BIL impulse withstand for a 25 kV joint?
For a 25 kV class joint, the BIL impulse withstand (1.2 x 50 μsec. wave) is 150 kV.
What is the short-time current rating?
The short-time current rating is equal to that of the cable rating, up to 35 kA.
Where can PCJ power cable joints be installed?
They can be installed in direct-burial, underground vault, and even overhead applications.
What is the continuous current rating?
The continuous current rating is equal to that of the cable rating.
What types of cables are compatible with PCJ joints?
They are designed for UD cable with concentric neutral and extruded insulation shielding. They also work with fabric-tape shielded or lead-jacketed cables using proper adapters.
How to Install the 15/25/35PCJ1 Series Straight Joint
This guide provides step-by-step instructions for installing the 15/25/35PCJ1 series straight joint, a permanent, fully shielded, and submersible joint for wire shielded cables.
Estimated time: 3h
Tools needed:
Wire brush, Crimping tool, Cable stripping tools, T&B WT3D tool (for 35kV only)
Supplies needed:
Joint Housing, Splice (Conductor Contact), Lubricant (DO NOT SUBSTITUTE), Deltec Cable ties TYD5135 (for 35kV only), #14 AWG copper wire (if needed), Appropriate electrical connector, Cable jacket reconstruction material
- Safety and Preparation
DANGER: De-energize all apparatus before installation or removal of parts. Inspect all components for damage, proper rating, and compatibility with cables. Gather all required tools and maintain a clean work area throughout the procedure.
- Prepare Cables for Joint Centerline
Overlap both cables and cut them 12 inches (305mm) from the joint centerline to ensure sufficient shield wire length. Where applicable, remove the cable jacket of Cable 1 to 37 inches (940mm) and Cable 2 to 21 inches (530mm). Fold back the shield wires. Finally, cut both cables at the joint centerline.
- Prepare Cable 1 and Store Housing
Taper the edge of Cable 1 insulation from 1/2 inch to 1-1/2 inches (13mm to 38mm). Clean and lubricate the insulation shield of Cable 1. Lubricate the inside bore of the joint housing on both ends. Slide the joint housing onto Cable 1, pushing it up to the shield wires.
- Prepare Cables for Splice Installation
Carefully remove the cable insulation and then the insulation shield from both cables. DO NOT CUT OR NICK THE CABLE INSULATION OR CONDUCTOR, as this will result in product failure and serious injury.
- Install the Splice
If conductors are aluminum, wire-brush them thoroughly and immediately insert them into the splice. Crimp the splice according to its specific recommendations. Wipe off any excess inhibitor. Verify the distance between cable insulations against the 'Max Check After' dimension in the provided table; redo assembly if it exceeds this. Remove any sharp protrusions or burrs from the crimped splice and thoroughly clean the joint assembly area of metal chips/filings. Clean the cables as indicated and apply lubricant in a manner that creates a build-up or ramp at the edge of the insulation shield.
- Complete Joint Assembly
Slide the joint housing into its final position, ensuring proper placement by observing and equalizing the deformation of the joint ends caused by the underlying cable insulation shield. For 35kV installations ONLY, install two DELTEC Cable ties on each end of the cable entrance, approximately 1/4 inch (6mm) from the splice edge, with the second tie 1/4 inch (6mm) from the first, offsetting the locking heads. Use a T&B WT3D tool to tighten and trim the ties. Remove and discard the yellow pin from the joint grounding eye.
- Grounding and Finalization
Retrain the shield wires and secure them to the ends of the joint. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye, and repeat for Cable 2. If shield wires are smaller than #14 AWG, use separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and remaining shield wires using an appropriate connector. Reconstruct the cable jacket (where applicable) over both cables and the joint housing.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.