ABB - Installation Products 252LRF - 25 kV, 200 Amp, Deadbreak, Elbow Probe
More images

ABB Installation Products 252LRF 25 kV, 200 Amp, Deadbreak, Elbow Probe

UPC: 075114326681


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This ABB 25 kV, 200 Amp Deadbreak Elbow Probe (SKU: 252LRF) is designed for underground electrical distribution systems. It features a center feed type and accommodates line wire ranges from #6 to #350 MCM and load wire ranges from #8 to #250 MCM. Key specifications include: - Rated Current: 200 Amps - Voltage Rating: 25 kV - Feed Type: Center - Gang: 2 - Ground Lug Size: (1) #14-2 - Overhead/Underground Line Feed: Top/bottom - Number of Terminals: 4 This component is essential for safe and reliable termination of underground power cables in utility and industrial applications.
  • 25 kV voltage rating
  • 200 Amp continuous current rating
  • Center feed type
  • Accommodates line wire #6-350MCM and load wire #8-250MCM

Specifications

Amperage Rating
200 A
Application
Designed to be used with 15/25kv Class Deadbreak Elbows
Connection
Threaded
Connection Type
Deadbreak Elbow Probe
Current Rating
200 A
Insulation
False
Length
2.64 in
Length
67.056 mm
Material
Copper
Series
252LRF
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Elbow Probe
Voltage Rating
25 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle. Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550.

K655YSR-K2320

600 Amp, 15-25kV, 600 Series Deadbreak Straight Receptacle. Cable Insulation Diameter 1.090 inch to 1.310 inch. Copper Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 450 /Compacted Solid 500/550.
Copper-coated conductor 1,90m 63A x2

173G0412

Copper-coated conductor 1,90m 63A x2
Solenoid Valve Connectors, Accessory, Thumb screw, Cabled Form A, B, ISB, and FW ISC

V-25TB

Solenoid Valve Connectors, Accessory, Thumb screw, Cabled Form A, B, ISB, and FW ISC
25kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #2 Compact/Solid Wire Size, Bi-Metal Compression Lug.

262LRJS-C5210

25kV 200 Amp, Loadbreak Jacket Seal Elbow Connector with Test Point, .805 inch - 1.060 Inch Cable Insulation Diameter, #2 Compact/Solid Wire Size, Bi-Metal Compression Lug.
Flood Seal Y-Type Disconnect Kit, NonFused, 600 volt. Main Size #14-#2, Tap Size #12-#4. Kit includes EPDM Rubber Twin Tape Insulating Sleeve and Cap, (1) Copper Disconnect Link. 1-1/2 inch long x 13/32 inch Outside Diameter. Male Diamond Marked around Center. (1) Tin Plated Aluminum Mechanical Fuse Clip, 1-1/16 inch long x 29/64 inch. Has 5/16-23 x .210 inch Screw. (1) Fuse Holder Sub-Assembly (1) Wood Dowel, Silicone Grease, Instruction Sheet.

DYU-M V1

Flood Seal Y-Type Disconnect Kit, NonFused, 600 volt. Main Size #14-#2, Tap Size #12-#4. Kit includes EPDM Rubber Twin Tape Insulating Sleeve and Cap, (1) Copper Disconnect Link. 1-1/2 inch long x 13/32 inch Outside Diameter. Male Diamond Marked around Center. (1) Tin Plated Aluminum Mechanical Fuse Clip, 1-1/16 inch long x 29/64 inch. Has 5/16-23 x .210 inch Screw. (1) Fuse Holder Sub-Assembly (1) Wood Dowel, Silicone Grease, Instruction Sheet.
200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.

376LR-H-5230

200 Amp, 35kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.850 inch to 1.050 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41.
200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

375LR-L-2270

200 Amp, 35kV, Loadbreak Elbow Connector without Test Point, Cable Insulation Diameter 1.180 inch to 1.465 inch. Copper Compression Lug, Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.
35kv, 200 Amp, Loadbreak, Elbow, with Sealing Kit, Cable Insulation Diameter 1.090-1.310 inches, Bi-Metal Lug, Conductor Size 2/0 Compressed/Stranded or 3/0 Compact/Solid.

375LR-K5250-SG3

35kv, 200 Amp, Loadbreak, Elbow, with Sealing Kit, Cable Insulation Diameter 1.090-1.310 inches, Bi-Metal Lug, Conductor Size 2/0 Compressed/Stranded or 3/0 Compact/Solid.

Frequently Asked Questions

Which industry standard does the 252LR Elbow Connector meet?

The 252LR Elbow Connector meets ANSI/IEEE Standard 386, Latest Revision.

What are the operating voltage limits for 25kV class?

For the 25kV voltage class, the maximum phase-to-ground operating voltage is 15.2kV and maximum phase-to-phase is 26.3kV.

What are the operating voltage limits for 15kV class?

For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV and maximum phase-to-phase is 14.4kV.

What is the 252LR Elbow Connector's voltage and current rating?

The 252LR Elbow Connector is a fully-rated 15/25kV, 200 Amp Class dead-break connector. It is designed for continuous operation at 200 Amps.

Is a sealing and grounding kit recommended for safety?

Yes, for safety purposes, a sealing and grounding kit with the deadbreak elbow is highly recommended.

What are the operating voltage limits for 25kV class?

For the 25kV voltage class, the maximum phase-to-ground operating voltage is 15.2kV and maximum phase-to-phase is 26.3kV.

Which industry standard does the 252LR Elbow Connector meet?

The 252LR Elbow Connector meets ANSI/IEEE Standard 386, Latest Revision.

Is a sealing and grounding kit recommended for safety?

Yes, for safety purposes, a sealing and grounding kit with the deadbreak elbow is highly recommended.

What is the 252LR Elbow Connector's voltage and current rating?

The 252LR Elbow Connector is a fully-rated 15/25kV, 200 Amp Class dead-break connector. It is designed for continuous operation at 200 Amps.

What are the operating voltage limits for 15kV class?

For the 15kV voltage class, the maximum phase-to-ground operating voltage is 8.3kV and maximum phase-to-phase is 14.4kV.

How to Install 252LR Deadbreak Elbow Connectors

A comprehensive guide for the safe installation and connection of 252LR Deadbreak Elbow Connectors to UD cable and 25kV class deadbreak bushings or accessory devices.

Estimated time: 1h 30m

Tools needed:

Wrench, Crimp tool, Wire brush, Fully insulated hot stick

Supplies needed:

252LR Elbow Connector Housing, Compression Lug, Probe, Probe Contact, Lubricant (supplied), Hold-down Bail, UD cable, No. 14 AWG (2.5mm) copper wire, Appropriate ground connector

  1. Ensure Safety and Inspect Components

    DANGER: All apparatus must be de-energized during installation or removal of parts. This product should only be installed by competent personnel trained in high voltage electrical equipment safety. Inspect all package contents to ensure they are complete and undamaged. Verify the elbow housing cable entrance size and compression lug size for proper fit with the cable. Check threads by hand-threading the probe into the compression lug; if resistance is encountered, check for damage and replace the component. If a test point cap is not installed, lubricate the cap and test point, then install the cap.

  2. Prepare and Train the Cable

    Train the UD cable to ease operation, ensuring a minimum of 20 inches (508.0mm) beyond the end of the cable pad mount transformer. Cut the excess cable squarely at the center line of the bushing. Unwrap and bind the concentric neutral wires 8-1/2 inches (216.0mm) back from the cable end. Carefully remove the shield and insulation from the cable end, cutting squarely without nicking the conductor. Wire brush bare aluminum conductors immediately and install the compression lug, rotating it to spread inhibitor. Align the lug's threaded hole with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Wipe off any excessive inhibitor. Remove the semi-con shield and bevel the insulation end a maximum of 1/8 inch (3.2mm). Thoroughly clean the insulation to remove all traces of conductive residue.

  3. Assemble the Elbow Connector

    Clean and lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; do not substitute. Slide the elbow connector onto the cable using a back and forth twisting motion, then wipe off all excess silicone lubricant. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, taking care not to cross-thread. Tighten the probe with a wrench until the wrench bends, indicating proper torque.

  4. Assemble Hold-Down Bail and Connect Neutral

    Place the hold-down bail into the hold-down bracket. Using a separate No. 14 AWG (2.5mm) copper wire or equivalent, insert one end through the grounding eye on the elbow and twist tightly, ensuring not to damage the eye. Twist all concentric neutral wires together and connect them to ground using an appropriate connector, providing adequate slack for elbow operation.

  5. Connect Elbow to Bushing Plug

    Clean the receptacle portion of the elbow connector and the mating bushing, then lubricate them with the supplied lubricant. IMPORTANT: Only lubricate if the transformer and elbow are known to be de-energized. Use a fully insulated hot stick to place the elbow onto the bushing. DANGER: Do not operate by hand. Do not separate if energized.

  6. Secure Elbow with Hold-Down Bail

    Pull the hold-down bail up over the crown or top of the elbow so that the eyebolt on the bail is directly over the operating eye. Tighten down on the elbow locator by turning the eyebolt in a clockwise direction. Adjust the nut on the eyebolt until it allows the eyebolt to seat securely in the locator. The nut should act as a stop to prevent the eyebolt from applying excessive force on the elbow. Once the nut is in its final position, it will not need readjustment when removing and replacing the elbow.

  7. Perform Voltage Test (Optional Verification)

    If the connector is equipped with an integral capacitance test point, remove the test point cap with a hot stick, peeling it off at an angle. WARNING: The voltage test point is a capacitance device, not directly connected to the conductor. Do not use conventional voltage measuring equipment. Test with a suitable sensing device made for capacitive test points to determine if the cable is energized. Contamination or incorrect equipment can provide a false 'no voltage' indication; treat the elbow as energized until confirmed by other means. After testing, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.