ABB - Installation Products 167ELR-6689-5220 - 15kV, 200 Amp, LoadBreak, Repair Elbow Connector/Extended Elbow, Cable Insulation .665-.895 inches, Bi-Metal Compression Lug, Conductor Size #2 Stranded/Compressed or #1 Compact/Solid. No Seal

ABB Installation Products 167ELR-6689-5220 15kV, 200 Amp, LoadBreak, Repair Elbow Connector/Extended Elbow, Cable Insulation…

UPC: 075114303859


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB Elastimold® 167ELR Repair Elbow Connector, SKU 167ELR-6689-5220, is a fully rated 15kV, 200 Amp Class loadbreak elbow connector designed for medium-voltage electrical distribution systems. This model features an extended length housing and compression lug, providing an additional +3.25 inches (82.6 mm) to accommodate cables that are too short for standard elbow connectors. This is crucial for repairing failed elbow connections where the cable must be stripped back and a new compression lug applied, or for gaining extra length when cables have been accidentally trimmed too short. It is designed for connecting to and operating 15kV Class, 95kV BIL apparatus. Key specifications include: - Voltage Class: 15kV (8.3kV Max Phase-to-Ground, 14.4kV Max Phase-to-Phase) - Impulse Withstand: 95kV BIL (1.2 x 50 microsecond wave) - AC Withstand: 34kV for 1 minute - DC Withstand: 53kV for 15 minutes - Corona Extinction: 11kV AC at 3pC sensitivity - Current Rating: 200 Amp Continuous and Loadbreak - Momentary & Fault Close Rating: 10kA Symmetrical for 10 Cycles The 167ELR accommodates cable insulation diameters ranging from 0.665 to 0.895 inches (16.89 to 22.73 mm), identified by the '6689' W Code. It supports conductor sizes of #2 stranded/compressed or #1 compact/solid. The connector features a fully shielded, fully submersible molded rubber housing with 100% peroxide-cured insulation, insert, and jacket for long-term reliability. It includes provisions for hot stick operation and ground wire connection. The bi-metal compression lug ensures excellent conductivity and corrosion resistance. This model does not include a test point. Typical applications include repairing failed elbow connections, extending cable length, and connecting new apparatus to existing cables in medium-voltage systems. The wide cable range minimizes the number of required cable sizes while maintaining full performance ratings per ANSI/IEEE Standard 386.
  • 15kV, 200 Amp Class Loadbreak Repair Elbow Connector
  • Extended length housing and compression lug (+3.25 inches / 82.6 mm)
  • Accommodates cable insulation diameters from 0.665 to 0.895 inches (16.89 to 22.73 mm)
  • Supports conductor sizes #2 stranded/compressed or #1 compact/solid
  • Fully shielded, fully submersible molded rubber housing with peroxide-cured insulation

Specifications

Amperage Rating
200 A
Application
Designed for connecting to and operating 15kV Class, 95kV BIL apparatus
Color
Black
Conductor Range
#2 STR/COMPR AWG , #1 SOL/COMPT AWG
Connection
Compression
Current Rating
200A
Environmental Conditions
Fully Submersible
Insulation
True
Length
11.7 in
Length
297.18 mm
Material
Bi-Metal Compression Lug
Material
Housing - EPDM-Rubber
Series
167ELR
Size
Cable Insulation Diameter 0.665 inch to 0.895 inch
Special Features
Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured insulation, insert and jacket. Provision for hot stick operation, Provision for ground wire connection. Wide cable range with minimum number of sizes. Extended Length Housing and Compression Lug - plus 3-1/4 inch (82.6mm)
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Repair Elbow Connector
Voltage Rating
15 kV
Voltage Rating
15kV
Width
7.1 in
Width
180.34 mm
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
25kV, 600 Amp, Deadbreak Elbow, No Sealing Kit, without Test Point, Cable Insulation .640-.820 inches, Bi-Metal Lug, Conductor Size AWG Compressed/Stranded #2 or Compacted/Solid #1 or mm2 Compact 35.

K655LR-F5220

25kV, 600 Amp, Deadbreak Elbow, No Sealing Kit, without Test Point, Cable Insulation .640-.820 inches, Bi-Metal Lug, Conductor Size AWG Compressed/Stranded #2 or Compacted/Solid #1 or mm2 Compact 35.
35kV, 200 Amp, LoadBreak, Elbow Connector with Test Point, Cable Insulation 1.090-1.310 inches, Bi-Metal Compression Lug, Conductor Size 1/0 Stranded/Compressed or 2/0 Compact/Solid. With Jacket Seal

376LR-K5240-S

35kV, 200 Amp, LoadBreak, Elbow Connector with Test Point, Cable Insulation 1.090-1.310 inches, Bi-Metal Compression Lug, Conductor Size 1/0 Stranded/Compressed or 2/0 Compact/Solid. With Jacket Seal
25kV, 200 Amp, LoadBreak, Repair Elbow Connector/Extended Elbow. Cable Insulation .740-.950 inches, Bi-Metal Compression Lug, Conductor Size 2/0 Stranded/Compressed or 3/0 Compact/Solid. No Seal

273ELR-7495-5250

25kV, 200 Amp, LoadBreak, Repair Elbow Connector/Extended Elbow. Cable Insulation .740-.950 inches, Bi-Metal Compression Lug, Conductor Size 2/0 Stranded/Compressed or 3/0 Compact/Solid. No Seal
15kV, 200 Amp, LoadBreak, Repair Elbow Connector/Extended Elbow, Cable Insulation .740-.950 inches, Bi-Metal Compression Lug, Conductor Size 2/0 Stranded/Compressed or 3/0 Compact/Solid. No Seal

167ELR-7495-5250

15kV, 200 Amp, LoadBreak, Repair Elbow Connector/Extended Elbow, Cable Insulation .740-.950 inches, Bi-Metal Compression Lug, Conductor Size 2/0 Stranded/Compressed or 3/0 Compact/Solid. No Seal
15kV, 200 Amp, LoadBreak, Repair Elbow Connector/Extended Elbow, Cable Insulation .665-.895 inches, Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67. No Seal

167ELR-6689-5210

15kV, 200 Amp, LoadBreak, Repair Elbow Connector/Extended Elbow, Cable Insulation .665-.895 inches, Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67. No Seal
15kV, 200 Amp, Straight Plug, Cable Insulation .635-.905 inches, Aluminum Compression Lug, Conductor Size 1/0 Stranded/Compressed or 2/0 Compact/Solid. With Jacket Seal.

K151SP-B0240-S

15kV, 200 Amp, Straight Plug, Cable Insulation .635-.905 inches, Aluminum Compression Lug, Conductor Size 1/0 Stranded/Compressed or 2/0 Compact/Solid. With Jacket Seal.
15kV, 200 Amp, LoadBreak, Repair Elbow Connector/Extended Elbow, Cable Insulation .740-.950 inches, Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67. No Seal

167ELR-7495-5210

15kV, 200 Amp, LoadBreak, Repair Elbow Connector/Extended Elbow, Cable Insulation .740-.950 inches, Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #3/Solid #2/mmSquared 26.67. No Seal
15kV, 200 Amp, LoadBreak, Repair Elbow Connector/Extended Elbow, Cable Insulation .665-.895 inches, Bi-Metal Compression Lug, Conductor Size #1 Stranded/Compressed or 1/0 Compact/Solid. No Seal

167ELR-6689-5230

15kV, 200 Amp, LoadBreak, Repair Elbow Connector/Extended Elbow, Cable Insulation .665-.895 inches, Bi-Metal Compression Lug, Conductor Size #1 Stranded/Compressed or 1/0 Compact/Solid. No Seal

Frequently Asked Questions

What is the catalog number for the test point cap?

The catalog number for the test point cap is 156-7.

Where are Elastimold 200 A elbows manufactured?

Elastimold 200 A repair and replacement elbows are designed, molded, tested, and assembled in Albuquerque, New Mexico, USA.

Are these connectors compliant with industry standards?

Yes, they are IEEE 386 compliant, ANSI certified, and Rural Utilities Service (RUS) accepted.

How much extra length does the replacement elbow provide?

The replacement elbow provides a net gain of 8 7⁄8 inches in length compared to a standard elbow.

How much extra length does the repair elbow provide?

The repair elbow provides a net gain of 3 1⁄4 inches in length compared to a standard elbow.

What voltage classes do these elbows support?

These elbow connectors are designed for 15 kV and 25 kV voltage classes.

What is the current rating of these connectors?

The Elastimold repair and replacement elbow connectors are rated for 200 A.

How much extra length does the repair elbow provide?

The repair elbow provides a net gain of 3 1⁄4 inches in length compared to a standard elbow.

Where are Elastimold 200 A elbows manufactured?

Elastimold 200 A repair and replacement elbows are designed, molded, tested, and assembled in Albuquerque, New Mexico, USA.

What is the catalog number for the test point cap?

The catalog number for the test point cap is 156-7.

How to Install the 168ELR Loadbreak Elbow Connector

This guide provides step-by-step instructions for the new installation and wiring of the 168ELR Loadbreak Elbow Connector, including cable preparation, assembly, and initial connection to a bushing.

Estimated time: 1h 30m

Tools needed:

Probe Wrench, Crimp tool, Wire brush, Hotstick, Suitable sensing device for capacitive test points, Wire strippers

Supplies needed:

Elbow Connector Housing, Compression Lug, Probe, Lubricant (Do Not Substitute), UD cable, No. 14 AWG / 2.5mm copper wire, Appropriate ground connector, Silicone grease

  1. Prepare for Installation and Inspect Components

    Ensure all apparatus is de-energized before beginning installation or removal of any parts, except for test point caps and indicators. Inspect all components for damage, proper rating, and compatibility with mating parts. Check the contents of the package to ensure completeness. Thread the probe into the compression lug to check for resistance; if encountered, replace damaged components. Have all required tools readily available and maintain cleanliness throughout the procedure. DANGER: All apparatus must be de-energized during installation or removal of part(s) except for test point caps and indicators that can be installed and operated energized. Failure to follow these instructions will result in damage to the product and serious or fatal injury.

  2. Train and Prepare the Cable

    Train the UD cable to ease future operation, ensuring a minimum of 20 inches beyond the end of the cable pad mount transformer. For new installations, cut excess cable squarely at the center line of the bushing. Unwrap and bind the concentric neutral wires 'X' inches back from the end of the cable (refer to the compression lug chart for specific 'X' dimension). Remove the shield and insulation from the cable end, cutting squarely without nicking the conductor.

  3. Install and Crimp the Compression Lug

    Wire brush the bare aluminum conductors immediately after preparation. Install the compression lug, rotating it to spread the inhibitor. Position the compression lug so its contact threaded hole aligns with the bushing bore. Refer to the crimp chart provided with the compression lug for recommended crimp tool information. Start crimping at the crimp line mark, rotating 180 degrees for each successive crimp. Carefully wipe any excessive inhibitor from the outside of the lug and cable.

  4. Prepare Insulation and Assemble Elbow Housing

    Remove the insulation shield as shown in the documentation. Bevel the insulation end a maximum of 1/8 inch, ensuring it is straight, smooth, and squared without cuts or nicks. Thoroughly clean the insulation to remove all traces of conductive residue. Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; DO NOT SUBSTITUTE. Slide the elbow connector onto the cable with a back-and-forth twisting motion, then wipe off all excess grease.

  5. Align Elbow and Install Probe

    Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, taking care not to cross-thread. The probe must turn freely for approximately four turns before becoming snug. Tighten the probe with the supplied probe wrench until the wrench bends, indicating proper torque.

  6. Connect Concentric Neutral Wires to Ground

    Using a separate copper wire (No. 14 AWG / 2.5mm or equivalent), insert one end through the grounding eye on the elbow. Twist it tightly, taking care not to damage the eye. Twist all concentric neutral wires together with the wire from the grounding eye and connect them to ground using an appropriate connector. Ensure adequate slack in the wires to allow for elbow operation.

  7. Connect Elbow to Bushing Plug (De-energized)

    Lubricate the receptacle portion of the elbow connector and the mating bushing with the supplied lubricant. This lubrication MUST ONLY be performed if the transformer and elbow are known to be de-energized. Do not operate the elbow by hand; use a full insulated 'hotstick' type live-line tool for all operations. DANGER: Lubricate only if the transformer and elbow are known to be de-energized. Do not operate by hand. Loadbreak connectors must be operated with a full insulated 'hotstick' type live-line tool.

  8. Perform Voltage Test (168ELR Only)

    If using the 168ELR with a test point, remove the test point cap with a hotstick, peeling it off at an angle rather than pulling directly. Use a suitable sensing device designed for capacitive test points to determine if the cable is energized; do NOT use conventional voltage measuring equipment. After testing, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point. WARNING: The voltage test point is a capacitance device; it is not directly connected to the conductor. Contamination, moisture, dirt, etc., around the test point or use of the wrong measuring equipment can provide a false 'no voltage' indication on an energized elbow. To prevent serious or fatal injury, treat the elbow as energized until the 'no voltage' test point indication is confirmed by other means.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.