
ABB Installation Products 274FLR1-D0220 Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port…
UPC: 075114153683
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Molded current limiting fuse housing for 15.5kV systems
- Accommodates cable insulation diameter from 0.890" to 1.220" (25-31mm)
- Supports aluminum conductors: 2 AWG stranded compressed or 1 AWG solid compact
- Includes two capacitive test ports for safe and efficient testing
- Compact housing design for optimized space utilization
Specifications
Amperage Rating | 200 A |
Application | Protect Light Duty Underground Distribution Systems |
Color | Black |
Conductor Range | #2 STR/COMPR AWG , #1 SOL/COMPT AWG |
Insulation | True |
Length | 16.87 in |
Length | 428.498 mm |
Material | EPDM-Rubber |
Special Features | Full-Range Current-Limiting Fusing with 50kA Interrupting Capability. Hotstick Operable 25/28kV Loadbreak Elbow Switching |
Standard | IEEE 386, ANSI C37.40, ANSI C37.41, ANSI C37.47 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Fused Elbow Connector with Test Point |
Voltage Rating | 15.5 to 16.2 kV |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

168FLR1-B5220
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Bi-Metal Conductor size 2 AWG Stranded/Compressed, 1 AWG Solid/Compact. no Sealing Kit
274AFLR1-B0220
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Direct Test Ports, Small Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 15-19mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid/Compact.
274AFLR3-D5240
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid/Compact. No Sealing, Size 3.
274AFLR3-C0220
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 2 AWG Stranded Compressed, 1 AWG Solid/Compact.
274AFLR3-C0240
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 17.2kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid/Compact.
168FLR3-C5250
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Bi-Metal, Conductor size 250 - 2/0 AWG Stranded/Compressed, 3/0 AWG Solid/Compact.
274FLR1-D5270-S
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Bi-Metal Conductor size 4/0 AWG Stranded Compressed. With Seal
274FLR1-C5240-S
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Bi-Metal Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid Compact. With SealFrequently Asked Questions
What cable insulation diameters are compatible?
The housing accommodates cable insulation diameters from 0.890 to 1.220 inches (25-31mm).
What voltage rating does this fuse housing support?
The fuse housing is rated for a nominal voltage of 15.5kV.
How many test ports are included?
The device features two capacitive test ports for electrical testing.
What conductor sizes can be used with this housing?
The housing supports 2 AWG stranded compressed or 1 AWG solid compact aluminum conductors.
Is this fuse housing suitable for outdoor installations?
The product's material and design suggest suitability for industrial environments, but specific environmental ratings are not provided.
How to Install the 274FLR Loadbreak Fused Elbow Connector
This guide provides detailed instructions for the safe and proper installation of the 274FLR Loadbreak Fused Elbow Connector, covering cable preparation, component assembly, and final connection to a bushing.
Estimated time: 1h 30m
Tools needed:
Probe Wrench, Allen Wrench (torque limiting, supplied), Wire brush, Crimp tool (specific to compression lug), Hotstick (insulated), Wire strippers
Supplies needed:
Fuse (appropriate for FLR-1 or FLR-3), Compression Lug (appropriate for cable), Probe, Probe Connector, Hose Clamp, Lubricant (supplied), 200ECS Cold Shrink Cable Seal (optional), Copper wire (No. 14 AWG / 2.5mm or equivalent), Grounding connector
- Perform Initial Safety Checks and Component Verification
Before starting, ensure all apparatus is de-energized. Inspect all package contents for completeness and damage. Verify all components, including the 168FLR or 274FLR, are compatible with the cable and mating products. Check the probe threads by hand-threading it into the compression lug; if resistance is met, replace damaged components. Have all required tools ready and maintain cleanliness throughout the procedure. This product must be installed by competent personnel trained in high voltage safety practices.
- Prepare the Cable for Termination
Using the bushing centerline as a reference, cut excess cable, leaving a minimum of 20 inches beyond the bushing. If using an optional 200ECS Cold Shrink Cable Seal, slide it onto the cable now. Remove the cable jacket for a length equal to 'A' (11-1/2” for FLR-1, 15-3/4” for FLR-3) plus 7-3/8” from the bushing centerline. If not using a cable seal kit, unwrap and fold the concentric neutral wires back over the jacket and bind them. Finally, squarely cut off the cable a distance of 'A' from the bushing centerline, ensuring 7-3/8” minimum of cable remains for termination.
- Prepare the Cable End and Install Compression Lug
Cut 1-1/8” from the cable end, ensuring a square cut and taking care not to nick the conductor. Wire brush the bare aluminum conductors immediately and install the compression lug. Rotate the lug to spread any inhibitor. Crimp the unthreaded end of the compression lug to the conductor, following the crimp chart provided with the lug. Start crimping at the crimp line mark, rotating 180 degrees for each successive crimp. Carefully wipe any excess inhibitor from the outside of the lug and cable. Remove the insulation shield 5-1/2” from the end of the lug and bevel the insulation end a maximum of 1/8”. Thoroughly clean the insulation to remove all traces of conductive residue.
- Lubricate and Insert Cable into Cable Half Housing
Apply the supplied lubricant to the outside of the connector, the cable insulation, the conductive shield, and the cable entrance end of the Fused Elbow cable half. Insert the prepared connector and cable into the cable half of the Fused Elbow until the top end of the connector protrudes beyond surface 'A' of the housing. This ensures proper fuse tightening without bottoming on the rubber.
- Install and Hand Tighten the Fuse
Insert the threaded terminal end of the fuse into the cable half of the Fused Elbow and thread it into the cable connector. Hand tighten the fuse. CAUTION: The fuse stud will fracture if over-torqued. After tightening, pull the cable half housing up against the bottom of the tightened fuse.
- Assemble and Lock the Probe Connector
Assemble the probe connector to the fuse terminal. Rotate the probe connector so its flats are perpendicular to the bushing with which it will mate. Lock the probe connector in position by tightening the setscrews using the special torque-limiting allen wrench supplied in the fuse kit. Rotate the cable half of the Fused Elbow so that its test point is perpendicular to the flats on the probe connector.
- Assemble Elbow Halves and Secure Probe
Apply lubricant to the elbow half of the fused elbow and assemble it to the cable half. The cuff of the cable half must overlap the elbow half by 3/4”. Ensure the probe connector faces the opening of the fused elbow half and that the two test points are aligned. Insert the probe into the probe connector; it may be necessary to push on the cable to align the probe with the fuse. Start the threads by hand, taking care not to cross-thread. Tighten the probe using the special torque-limiting allen wrench supplied, inserting the short end into the hole in the probe and tightening until the wrench bends and remains bent. Position the hose clamp as shown in the diagram and tighten it, but DO NOT OVERTIGHTEN.
- Connect Concentric Neutral Wires to Ground
Using a separate copper wire (No. 14 AWG / 2.5mm or equivalent), insert one end through each grounding eye on both the elbow housing and cable housings. Twist the wire tightly, taking care not to damage the grounding eyes. If used, finish installing the 200ECS jacket seal. Twist all neutral wires together, exercising care not to damage the grounding eyes, and connect them to ground using an appropriate connector. Ensure adequate slack in the wires to allow for elbow operation.
- Connect the Fused Elbow to the Bushing Plug
Lubricate the receptacle portion of the elbow connector and the mating bushing with the lubricant supplied. WARNING: Lubricate ONLY if the transformer and elbow are known to be DE-ENERGIZED. Connect the elbow to the bushing plug using a full insulated 'hotstick' type live-line tool. DO NOT OPERATE BY HAND.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.