Authorized ABB Distributor (Installation Products)
ABB - Installation Products 168FLR3-C5250 - Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Bi-Metal, Conductor size 250 - 2/0 AWG Stranded/Compressed, 3/0 AWG Solid/Compact.

ABB Installation Products 168FLR3-C5250 Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port…

UPC: 075114345347


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 168FLR3-C5250 is a molded current limiting fuse housing designed for robust electrical protection. This unit features a nominal fuse voltage rating of 8.3kV, making it suitable for medium-voltage applications. Equipped with two capacitive test ports, it facilitates safe and efficient fuse testing and diagnostics. The large housing design accommodates a cable insulation diameter ranging from 0.805 to 1.060 inches (20-27mm). Constructed with bi-metal components, this housing is engineered for reliable performance. It supports a wide range of conductor sizes, including 250 to 2/0 AWG stranded/compressed conductors and 3/0 AWG solid/compact conductors. The ABB 168FLR3-C5250 ensures secure mounting and protection for current limiting fuses in critical electrical infrastructure. Key specifications include: Nominal Fuse Voltage Rating: 8.3kV, Fuse Test Ports: Two Capacitive Test Ports, Cable Insulation Diameter: 0.805 - 1.060 inch / 20-27mm, Conductor Size Compatibility: 250 - 2/0 AWG Stranded/Compressed, 3/0 AWG Solid/Compact. This fuse housing is a vital component for maintaining system integrity and preventing damage from overcurrent events in industrial settings. SKU: 168FLR3-C5250. Manufacturer: ABB - Installation Products.
  • Nominal Fuse Voltage Rating: 8.3kV
  • Fuse Test Port: Two Capacitive Test Ports
  • Cable Insulation Diameter: 0.805 inch - 1.060 inch / 20-27mm
  • Conductor Size: 250 - 2/0 AWG Stranded/Compressed
  • Conductor Size: 3/0 AWG Solid/Compact

Specifications

Amperage Rating
200 A
Application
Protect Light Duty Underground Distribution Systems
Color
Black
Conductor Range
2/0 STR/COMPR AWG , 3/0 SOL/COMPT AWG
Connection
Compression
Insulation
True
Length
21.12 in
Length
536.448 mm
Material
EPDM-Rubber
Special Features
Full-Range Current-Limiting Fusing with 50kA Interrupting Capability. Hotstick Operable 15kV Loadbreak Elbow Switching
Standard
IEEE 386, ANSI C37.40, ANSI C37.41, ANSI C37.47
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Fused Elbow Connector
Voltage Rating
8.3 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2/0 AWG Stranded/Compressed, 3/0 AWG Solid/Compact.

168FLR3B0250

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 2/0 AWG Stranded/Compressed, 3/0 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Bi-Metal Conductor size 4/0 AWG Stranded Compressed. With Seal

274FLR1-D5270-S

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Bi-Metal Conductor size 4/0 AWG Stranded Compressed. With Seal
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Bi-Metal Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid Compact. With Seal

274FLR1-C5240-S

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Bi-Metal Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid Compact. With Seal
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 3/0 AWG Stranded Compressed, 4/0 AWG Solid/Compact.

168AFLR3-C0260

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 3/0 AWG Stranded Compressed, 4/0 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 3/0 AWG Stranded Compressed, 4/0 AWG Solid Compact, No Sealing

274FLR1-D0260

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 15.5kV, Fuse Test Port - Two Capactive Test Ports, Small Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 3/0 AWG Stranded Compressed, 4/0 AWG Solid Compact, No Sealing
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid/Compact.

168AFLR3-C0240

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid/Compact.

168AFLR3-B0240

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 1/0 AWG Stranded Compressed, 2/0 AWG Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 1 AWG Stranded Compressed, 1/0 AWG Solid/Compact.

168AFLR3-B0230

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Large Housing, Cable Insulation Diameter 0.635 inch - 0.905 inch / 16-23mm, Aluminum Conductor size 1 AWG Stranded Compressed, 1/0 AWG Solid/Compact.

Frequently Asked Questions

What is the voltage class of the 168FLR?

The 168FLR is designed for a 15kV voltage class, with an 8.3kV nominal fuse voltage and a 10kV maximum rated fuse voltage.

What items are included in the 168FLR kit?

Each kit contains an elbow connector housing, a crimp connector, a probe lug, lubricant tubes, installation instructions, and a crimp chart.

What is the impulse withstand rating of the 168FLR?

The 168FLR has a 95kV BIL impulse withstand rating, measured with a 1.2 x 50 microsecond wave.

How do I choose the proper compression lug code?

Choose the proper compression lug code from the Conductor Code Table according to the conductor size.

How do I determine the cable insulation diameter code?

Measure the cable's insulation diameter and select the insulation letter code from the W table that best straddles that diameter.

How do I select the correct housing size for the 168FLR?

Select the housing size based on the desired fuse. Housing 1 is for 3-45A 8.3kV and 6-20A 15.5kV fuses, while Housing 3 is for 65-80A 8.3kV and 3-45A 17.2kV fuses.

What types of conductors are compatible with the lugs?

Copper compression lugs are suitable for all copper conductors. Bi-metal compression lugs with universal aluminum barrels are suitable for copper or aluminum conductors.

What industry standards does the 168FLR meet?

The 168FLR meets applicable portions of IEEE, ANSI, and other industry standards, including IEEE 386 and ANSI C37.40, C37.41, and C37.47.

Is the 168FLR Loadbreak Fused Elbow submersible?

Yes, the Elastimold 168FLR Loadbreak Fused Elbow is fully sealed and submersible.

What is the current rating range of the fused elbow?

The current rating for the fused elbow is between 3 and 80 Amps. It also has a 50,000 Amp symmetrical interrupting capability.

How to Install the 168FLR Loadbreak Fused Elbow Connector

This guide provides step-by-step instructions for the safe installation and assembly of the 168FLR Loadbreak Fused Elbow Connector, including cable preparation, component assembly, and neutral connections. Ensure all apparatus are de-energized before beginning installation.

Estimated time: 1h 30m

Tools needed:

Cable cutters, Cable stripping tool, Wire brush, Crimp tool, Special torque limiting allen wrench (supplied), Screwdriver, Hotstick

Supplies needed:

168FLR Loadbreak Fused Elbow Connector kit, UD cable, No. 14 AWG (2.5mm) copper wire, Grounding connector, Optional 200ECS Cold Shrink Cable Seal, Binding material, Cleaning solution, Mating 15kV class 200A loadbreak bushing or accessory device

  1. Perform Preliminary Safety Checks and Cable Training

    DANGER: Ensure all apparatus are de-energized before starting installation to prevent serious injury or death. Inspect all kit contents for damage and compatibility. Using the bushing centerline as reference, cut excess cable 20 inches minimum beyond the bushing. Slide the optional 200ECS Cold Shrink Cable Seal onto the cable if used. Remove the cable jacket for a length of 'A' + 7-3/8 inches from the bushing centerline. Unwrap and fold concentric neutral wires back over the jacket, then bind them. Squarely cut the cable a distance of 'A' from the bushing centerline, leaving 7-3/8 inches minimum for termination. ('A' = 11-1/2 inches for FLR-1, 15-3/4 inches for FLR-3).

  2. Prepare Cable End and Install Compression Lug

    Cut 1-1/8 inches squarely from the cable end, ensuring not to nick the conductor. Wire brush the bare aluminum conductors and immediately install the compression lug, rotating to spread inhibitor. Crimp the unthreaded end of the lug to the conductor, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe off any excess inhibitor. Remove the insulation shield 5-1/2 inches from the end of the lug and bevel the insulation end by 1/8 inch maximum. Thoroughly clean the insulation to remove all traces of conductive residue.

  3. Lubricate and Assemble Cable Half Housing

    Apply the supplied lubricant to the outside of the connector, cable insulation, conductive shield, and the cable entrance end of the Fused Elbow cable half. DO NOT SUBSTITUTE LUBRICANT. Insert the connector and cable into the cable half of the Fused Elbow until the top end of the connector protrudes beyond surface 'A'. This allows the fuse to be tightened before bottoming on the rubber.

  4. Install Fuse and Probe Connector

    Insert the threaded terminal end of the fuse into the cable half of the Fused Elbow and thread it into the cable connector. HAND TIGHTEN the fuse; CAUTION: over-torquing will fracture the fuse stud. Pull the housing up against the bottom of the tightened fuse. Assemble the probe connector to the fuse terminal, rotating it so the flats are perpendicular to the mating bushing. Lock the probe connector in position by tightening the setscrews using the special torque-limiting allen wrench provided. Rotate the cable half of the Fused Elbow so its test point is perpendicular to the flats on the probe connector.

  5. Assemble Elbow Half Housing and Probe

    Apply the supplied lubricant to the elbow half of the fused elbow and assemble it to the cable half, ensuring a 3/4 inch overlap. Verify the probe connector faces the opening of the fused elbow half and that both test points are in line. Insert the probe into the probe connector, starting threads by hand to prevent cross-threading. Tighten the probe using the special torque-limiting allen wrench until the wrench bends and remains bent. Position the hose clamp as shown in the diagram and tighten it, but DO NOT OVERTIGHTEN.

  6. Connect Concentric Neutral Wires

    Using a separate No. 14 AWG (2.5mm) copper wire, insert one end through each grounding eye on the elbow housing and cable housings. Twist the wire tightly, taking care not to damage the eyes. If used, finish installing the 200ECS jacket seal. Twist all neutral wires together, ensuring not to damage grounding eyes, and connect them to ground using an appropriate connector. Provide adequate slack in the wires to allow for elbow operation.

  7. Connect Fused Elbow to Mating Bushing

    DANGER: Lubricate the receptacle portion of the elbow connector and the mating bushing ONLY IF THE TRANSFORMER AND ELBOW ARE KNOWN TO BE DE-ENERGIZED. Connect the elbow to the bushing using a full insulated hotstick type live-line tool, following company safe work practices and operating instructions. DO NOT OPERATE BY HAND.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.