Authorized ABB Distributor (Installation Products)
ABB - Installation Products 655LINKCLRJ0270BDRG - 600 Amp, Dead Break, Elbow Connector, Cam-Op Connector Kit, 15KV, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67.

ABB Installation Products 655LINKCLRJ0270BDRG 600 Amp, Dead Break, Elbow Connector, Cam-Op Connector Kit, 15KV, Cable Insulation…

UPC: 783786512508


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 655LINKCLRJ0270BDRG is a 600 Amp, 15kV dead break elbow connector kit designed for medium-voltage distribution systems. The kit includes an aluminum compression lug for low-resistance electrical contact and long-term mechanical integrity. Key specifications include a continuous current rating of 600 Amps, a maximum phase-to-ground operating voltage of 8.3kV, and a maximum phase-to-phase voltage of 14.4kV. The connector meets ANSI/IEEE Standard 386 and offers a 95kV BIL impulse withstand rating (1.2 x 50 microsecond wave), 34kV AC one-minute withstand, and 53kV DC 15-minute withstand. It also features a 11kV AC corona extinction at 3pC sensitivity and a 25kA symmetrical momentary rating for 10 cycles. The Cam-Op mechanism simplifies installation by eliminating the need for separate tools, reducing labor time while maintaining consistent compression force. This dead break connector is ideal for underground residential distribution (URD) systems, pad-mounted transformers, and switchgear installations where load-break capability is not required. It supports hotstick operations for de-energized primary feeder or network circuits, allowing external visible break, testing, grounding, and isolation. Compatible with Elastimold 15/25/35kV Class 600A deadbreak elbow and splice products, this connector kit is suitable for utility and industrial power distribution networks operating at medium voltage levels. The aluminum compression lug ensures compatibility with both copper and aluminum conductors, providing flexibility in system design and installation.
  • 600 Amp continuous current rating with 25kA symmetrical momentary rating
  • 15kV class dead break elbow connector kit with Cam-Op mechanism
  • Supports cable insulation diameters from 0.980 inch to 1.180 inch
  • Meets ANSI/IEEE Standard 386 with 95kV BIL impulse withstand rating

Specifications

Amperage Rating
600 A
Application
External Visible Break, Testing, Grounding and Isolation
Color
Black
Conductor Range
4/0 STR/COMPR AWG , 250 kcmil
Connection
Compression
Connection Type
Cam-Op Connector
Current Rating
600 A
Insulation
True
Material
Aluminum
Material
EPDM-Rubber
Series
655LINKCLRJ
Size
Cable Insulation Diameter 0.980 inch to 1.180 inch
Size
20.50 inches from edge of Lever to Bushing Flange
Special Features
Easily Installed or Removed by Hotstick Operation of the Cam Action Disconnect Lever
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Cam_OP Connector Kit
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.

162LR-D5270-S

200 Amp, 15kV, Loadbreak Elbow Connector, Cable Insulation Diameter 0.890 inch to 1.220 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 4/0 /Solid 250 /mmSquared 126.67. 200ECS Jacket Seal Included.
600 Amp, DeadBreak Elbow Connector, 2-Way L Kit, 35KV, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185. Cold-Shrinkable Jacket Seal Included.

755L2-M0300-S

600 Amp, DeadBreak Elbow Connector, 2-Way L Kit, 35KV, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Compression Lug. Conductor Size AWG or kcmil, Compressed Stranded 350 /Compacted Solid 400 /mmSquared Compact 185. Cold-Shrinkable Jacket Seal Included.
25kV, Fused Elbow Housing - Full Range Current Limiting Fuse, with Test Point. Cable Insulation Diameter C - 0.805-1.060 inch, Conductor Size 230 is #1 Stranded/Compressed, 1/0 Compact/Solid. Aluminum Connector.

274FLR-C0230

25kV, Fused Elbow Housing - Full Range Current Limiting Fuse, with Test Point. Cable Insulation Diameter C - 0.805-1.060 inch, Conductor Size 230 is #1 Stranded/Compressed, 1/0 Compact/Solid. Aluminum Connector.
600 Amp, Dead Break, Elbow Connector, Retrofit Cam-Op Connector Kit, 15 KV, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1000. Options AEBED

655LINKCLRN0410AEBED

600 Amp, Dead Break, Elbow Connector, Retrofit Cam-Op Connector Kit, 15 KV, Cable Insulation Diameter 1.515 inch to 1.780 inch. Aluminum Compression Lug. Conductor Size AWG Compressed Stranded 1000. Options AEBED
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 4/0 AWG Stranded/Compressed.

168FLR3-D0270

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Capacitive Test Ports, Large Housing, Cable Insulation Diameter 0.890 inch - 1.220 inch / 25-31mm, Aluminum Conductor size 4/0 AWG Stranded/Compressed.
15 kV, 200 Amp Loadbreak Repair Elbow without Test Point. Cable Insulation Diameter 0.740 to 0.950 inch. #1 Stranded/Compressed or 1/0 Solid/Compact.

167ELR-7495-230

15 kV, 200 Amp Loadbreak Repair Elbow without Test Point. Cable Insulation Diameter 0.740 to 0.950 inch. #1 Stranded/Compressed or 1/0 Solid/Compact.
Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 4/0 AWG Stranded Compressed

168AFLR1-C0270

Molded Current Limiting Fuse Housing, Nominal Fuse Voltage Rating 8.3kV, Fuse Test Port - Two Direct Test Ports, Small Housing, Cable Insulation Diameter 0.805 inch - 1.060 inch / 20-27mm, Aluminum Conductor size 4/0 AWG Stranded Compressed
15-25kV 600 Series Deadbreak 3-Way Insulated Bus Bar with Test Point, with Spiking Aid.

K656CYSL-BUS

15-25kV 600 Series Deadbreak 3-Way Insulated Bus Bar with Test Point, with Spiking Aid.

Frequently Asked Questions

What are the applications of this connector kit?

The 655LINK-C-LR-W0X-B-DRG CAM-OP Connector Kit is used for hotstick operations on de-energized primary feeder or network circuits. It allows for external visible break, testing, grounding, and isolation.

What cable insulation diameters are compatible?

Compatible cable insulation diameters range from 0.640 inches to 1.935 inches, corresponding to W codes F through P.

What is the corona extinction voltage?

The corona extinction voltage is 11kV AC at 3pC sensitivity.

What is the DC 15-minute withstand voltage?

The kit has a DC 15-minute withstand rating of 53kV.

What is the AC one-minute withstand voltage?

The kit has an AC one-minute withstand rating of 34kV.

What conductor sizes are compatible with the compression lug?

The compression lug supports a wide range of conductor sizes, including AWG/kcmil from 2 to 1250 and mm2 from 35 to 500.

What is the impulse withstand rating of the kit?

The kit has a 95kV BIL Impulse Withstand rating, based on a 1.2 x 50 microsecond wave.

What industry standards does the connector kit meet?

The connector kit meets ANSI/IEEE Standard 386, Latest Revision.

What is the continuous current rating of the connector kit?

The CAM-OP Connector Kit has a continuous current rating of 600 Amps.

What is the maximum operating voltage for this kit?

The maximum phase-to-ground operating voltage is 8.3kV, and the maximum phase-to-phase voltage is 14.4kV for the 15kV Voltage Class.

How to Install the LINK-C Deadbreak Cam Link Operable Connector System

This guide provides step-by-step instructions for the safe installation and setup of the LINK-C 600 amp deadbreak cam link operable connector system, including mounting, wiring, and grounding procedures.

Estimated time: 1h

Tools needed:

Torque wrench, Socket wrench (1 inch hex), Hot stick, Wire strippers, 600ATM Operating Tool

Supplies needed:

ELASTIMOLD supplied lubricant, #14 AWG or #12 AWG solid copper wire, Appropriate grounding connector, HV insulated cap(s) or connector(s) (if replacing shipping covers)

  1. Prepare for Installation and Ensure Safety

    DANGER: Ensure all apparatus is de-energized before beginning installation or removal of any parts. This product must only be installed by competent personnel trained in high voltage electrical equipment safety practices. Inspect all parts for damage, proper rating, and compatibility with mating components. If supplied with protective shipping covers, remove them and replace with appropriate HV insulated caps or connectors before energizing or submerging the circuit. Read all instructions thoroughly before starting.

  2. Install the 600 Amp Elbow onto the Cable

    Install the 600 amp elbow onto the cable according to the specific installation instructions provided with the elbow. Ensure it is positioned to properly align with the stand-off plug or apparatus bushing.

  3. Install the Bushing Extender

    Clean and thoroughly lubricate the apparatus bushing and both interfaces of the 600 amp bushing extender using ELASTIMOLD supplied lubricant. Insert the 600ATM Operating Tool into the retainer contact and engage its internal hex broach. Install the bushing extender onto the apparatus bushing. Insert the retainer contact into the bushing extender and thread it into the apparatus bushing using a suitable tool applied to the 1-inch hex portion of the 600ATM Operating Tool. Torque to 50-60 ft-lbs.

  4. Install the 600 Amp Elbow onto the Epoxy Standoff Plug

    Clean and thoroughly lubricate the epoxy standoff plug and both interfaces of the 600 amp elbow with ELASTIMOLD supplied lubricant. Insert the 600ATM Operating Tool into the retainer contact and engage its internal hex broach. Install the elbow onto the epoxy standoff plug. Insert the retainer contact into the 600 amp elbow through the hole in the compression lug and thread it into the epoxy standoff plug using a suitable tool applied to the 1-inch hex portion of the 600ATM Operating Tool. Torque to 50-60 ft-lbs.

  5. Install the Alignment Bracket

    Remove the bushing extender clamp and elbow clamp from the alignment bracket. Position the alignment bracket on the bushing extender at a dimension of 2.5 inches (63.5mm) from the grounding eye. Assemble the bushing extender clamp to the alignment bracket with the supplied hardware, torquing by alternating sides until the clamp tabs are flush and tight on both sides.

  6. Position and Secure the Elbow in the Alignment Bracket

    Position the elbow in the alignment bracket so that the elbow cuff is lined up evenly with the bushing extender cuff. Assemble the elbow clamp to the alignment bracket with the supplied hardware, torquing by alternating sides until the clamp tabs are flush and tight on both sides. Ensure the elbow clamp notch faces the cable entrance of the elbow.

  7. Insert and Engage the LINK-C Connector

    Clean and thoroughly lubricate both 600 ampere interfaces of the Link with ELASTIMOLD supplied lubricant. Align the Link so it is perpendicular to the switch faceplate when inserted into the bushing extender and elbow. Insert the Link, ensuring both lever arms are on the inside of the alignment bracket legs. Engage the pivot pin into the slots in the alignment bracket legs. While pushing inward, move the lever arms downward using a hot stick eye, engaging the roller pin and moving the Link inward. Continue moving lever arms until they are perpendicular to the alignment bracket leg.

  8. Ground the System and Install Mating Products

    Ground the elbow by feeding a #14 AWG or #12 AWG solid copper wire through the grounding eye, twisting it tight, and connecting it to ground. Clean and lubricate the 200 amp interface on the Link. Ground the cable: if using concentric neutral cable, twist the neutral wires together and connect to ground with an appropriate connector; if using 20MA or 21MA grounding devices, connect the ground lead to ground with a suitable connector. For three-phase installations, tie all grounds from all three phases to a common ground point. Install the desired 200 amp mating product onto the Link's 200 amp interface according to its specific instructions.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.