ABB Installation Products 167ELR-6689-5230 15kV, 200 Amp, LoadBreak, Repair Elbow Connector/Extended Elbow, Cable Insulation…
UPC: 075114305525
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- 15kV, 200 Amp Class Loadbreak Elbow Connector
- Extended length housing and compression lug (+3-1/4" / 82.6 mm)
- Accommodates cable insulation diameters from 0.665 to 0.895 inches
- Bi-metal compression lug for reliable conductivity
- Fully shielded, fully submersible molded rubber housing
Specifications
Amperage Rating | 200 A |
Application | Designed for connecting to and operating 15kV Class, 95kV BIL apparatus |
Color | Black |
Conductor Range | #1 STR/COMPR AWG , 1/0 SOL/COMPT AWG |
Connection | Compression |
Connection Type | LoadBreak, Repair Elbow Connector |
Current Rating | 200 A |
Environmental Conditions | Fully Submersible |
Insulation | True |
Length | 11.7 in |
Length | 297.18 mm |
Material | Bi-Metal |
Material | Housing - EPDM-Rubber |
Series | 167ELR |
Size | Cable Insulation 0.665-0.895 inches, Conductor Size #1 Stranded/Compressed or 1/0 Compact/Solid |
Special Features | Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured insulation, insert and jacket. Provision for hot stick operation, Provision for ground wire connection. Wide cable range with minimum number of sizes. Extended Length Housing and Compression Lug - plus 3-1/4 inch (82.6mm) |
Standard | ANSI/IEEE Standard 386 |
Temperature Rating, Maximum | 149 F |
Temperature Rating, Maximum | 65 C |
Temperature Rating, Minimum | -40 F |
Temperature Rating, Minimum | -40 C |
Type | Loadbreak Repair Elbow Connector |
Voltage Rating | 15 kV |
Width | 7.1 in |
Width | 180.34 mm |
Package Dimensions (L x W x H) | 0.01 IN x 0.01 IN x 0.01 IN |
Package Dimensions (L x W x H) | 0.0254 cm x 0.0254 cm x 0.0254 cm |
Package Weight (Imperial) | 1.0000 L |
Package Weight (Metric) | 0.4540 kg |

168RLR-F-5230
200 Amp, 15kV, Loadbreak Replacement Elbow Connector with Test Point, Cable Insulation Diameter 0.640 inch to 0.820 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded #1/Solid 1/0 /mmSquared 42.41. Repair Elbow has extended length contact and elbow housing resulting in a net gain of 8-7/8 inches in length. Includes 00400X long Bi-Metal Contact.
167ELR-7495-5220
15kV, 200 Amp, LoadBreak, Repair Elbow Connector/Extended Elbow, Cable Insulation .740-.950 inches, Bi-Metal Compression Lug, Conductor Size #2 Stranded/Compressed or #1 Compact/Solid. No Seal
168ELR-6689-5230
15kV, 200 Amp, LoadBreak, Repair Elbow Connector with Test Point/Extended Elbow, Cable Insulation .665-.895 inches, Bi-Metal Compression Lug, Conductor Size #1 Stranded/Compressed or 1/0 Compact/Solid. No Seal.
167ELR-88110-5230
15kV, 200 Amp, LoadBreak, Repair Elbow Connector/Extended Elbow, Cable Insulation .880-1.100 inches, Bi-Metal Compression Lug, Conductor Size #1 Stranded/Compressed or 1/0 Compact/Solid. No Seal
167ELR-7495-5270
15kV, 200 Amp, LoadBreak, Repair Elbow Connector/Extended Elbow, Cable Insulation .740-.950 inches, Bi-Metal Compression Lug, Conductor Size 4/0 Stranded/Compressed or 250 Compact/Solid. No Seal
168ELR-6689-5230-S
15kV, 200 Amp, LoadBreak, Repair Elbow Connector with Test Point/Extended Elbow, Cable Insulation .665-.895 inches, Bi-Metal Compression Lug, Conductor Size #1 Stranded/Compressed or 1/0 Compact/Solid. With Jacket Seal.
167ELR-88110-5240
15kV, 200 Amp, LoadBreak, Repair Elbow Connector/Extended Elbow, Cable Insulation .880-1.100 inches, Bi-Metal Compression Lug, Conductor Size 1/0 Stranded/Compressed or 2/0 Compact/Solid. No Seal
167ELR-7495-5260
15kV, 200 Amp, LoadBreak, Repair Elbow Connector/Extended Elbow, Cable Insulation .740-.950 inches, Bi-Metal Compression Lug, Conductor Size 3/0 Stranded/Compressed or 4/0 Compact/Solid. No SealFrequently Asked Questions
What is the voltage rating of this elbow connector?
The ABB 167ELR-6689-5230 elbow connector has a voltage rating of 15kV.
What is the maximum current this connector can handle?
This loadbreak repair elbow connector is rated for 200 Amps.
What cable insulation sizes are compatible with this connector?
This connector is designed for cable insulation sizes ranging from 0.665 to 0.895 inches.
What conductor sizes can be used with this ABB elbow connector?
It is compatible with #1 Stranded/Compressed or 1/0 Compact/Solid conductor sizes.
What type of lug material is used in this connector?
The connector features a bi-metal compression lug for enhanced conductivity and durability.
Is this an extended elbow connector?
Yes, this product is described as a Repair Elbow Connector/Extended Elbow.
What is the series of this ABB connector?
This connector belongs to the ABB 167ELR series.
How to Install 167ELR/168ELR Loadbreak Elbow Connectors
This guide provides step-by-step instructions for the new installation and initial setup of 167ELR and 168ELR Loadbreak Elbow Connectors, including cable preparation, assembly, grounding, and voltage testing.
Estimated time: 1h 30m
Tools needed:
Pin wrench, Crimp tool, Wire brush, Hotstick, Suitable sensing device (for capacitive test points)
Supplies needed:
Lubricant (Do Not Substitute), Copper wire (No. 14 AWG / 2.5mm or equivalent), Appropriate grounding connector, HV insulated cap(s) or connector(s) (if replacing shipping covers), Silicone grease
- Ensure De-energized State and Inspect Components
DANGER: All apparatus must be de-energized during installation or removal of parts. Inspect all components for damage, proper rating, and compatibility with the cable and mating parts. Check the contents of the package to ensure they are complete and undamaged. If the product is supplied with protective shipping covers, remove them and replace with appropriate HV insulated caps or connectors before submerging or energizing the circuit.
- Train and Cut Cable
Train the cable as shown in the documentation to ease future operation. For new installations, cut any excess cable squarely at the center line of the bushing. For replacements, remove the old probe using a pin wrench, pull the old elbow off the cable with a twisting motion, and cut off the old compression lug.
- Prepare Cable End and Install Compression Lug
Unwrap and bind the concentric neutral wires 'X' inches back from the end of the cable (refer to the compression lug X dimension chart). Remove the shield and insulation from the cable end, cutting squarely and taking care not to nick the conductor. Wire brush the bare aluminum conductors and immediately install the compression lug. Rotate the lug to spread the inhibitor and position it so the contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe excessive inhibitor from the outside of the lug and cable.
- Prepare Insulation Shield and Clean Cable
Remove the insulation shield as shown in the documentation. Bevel the insulation end a maximum of 1/8 inch. Thoroughly clean the insulation to remove all traces of conductive residue, ensuring a straight, smooth, and squared surface without nicks or cuts.
- Assemble Elbow Housing and Probe
Lubricate the cable insulation and the inside of the elbow housing with the supplied lubricant; DO NOT SUBSTITUTE. Slide the elbow connector onto the cable with a back-and-forth twisting motion, then wipe off all excess grease. Align the elbow with the compression lug's threaded hole. Thread the probe into the lug by hand, ensuring not to cross-thread. The probe should turn freely for approximately four turns before becoming snug. Tighten the probe with a wrench until the wrench bends.
- Connect Concentric Neutral Wires
Using a separate copper wire (No. 14 AWG / 2.5mm or equivalent), insert one end through the grounding eye on the elbow. Twist it tight, taking care not to damage the eye. Twist all neutral wires together with the wire from the grounding eye and connect them to ground using an appropriate connector. Provide adequate slack in the wires for elbow operation.
- Lubricate Elbow for Connection
Lubricate the receptacle portion of the elbow connector and the mating bushing with the lubricant supplied. CAUTION: Lubricate only if the transformer and elbow are known to be de-energized. Do not operate by hand; use a full insulated hotstick type live-line tool for connection.
- Perform Voltage Test (168ELR Only)
For 168ELR models with a test point, remove the test point cap with a hotstick, peeling it off at an angle. WARNING: The voltage test point is a capacitance device; do not use conventional voltage measuring equipment. Test with a suitable sensing device designed for capacitive test points, following the manufacturer's directions. Treat the elbow as energized until the 'no voltage' indication is confirmed by other means. After testing, clean and lubricate the inside surface of the cap with silicone grease and replace it on the test point.
Frequently Asked Questions about ABB - Installation Products
How are Thomas and Betts products typically installed?
Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.
What accessories are available for Thomas and Betts products?
Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.
What environmental ratings do Thomas and Betts products have?
Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.
What communication protocols do Thomas and Betts products support?
Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.
What are the key features of Thomas and Betts products?
Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.
What are the main product lines offered by Thomas and Betts?
Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.
What technical support does Thomas and Betts offer?
Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.
What industries and applications are Thomas and Betts products used for?
Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.
What certifications and standards do Thomas and Betts products comply with?
Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.
What are the main product lines offered by Ocal?
Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.