Authorized ABB Distributor (Installation Products)
ABB - Installation Products 162LR-B5240-SG2 - 200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.635 inch to 0.905 inch. Bi-Metal Compression Lug. Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49. 200ECS-G2 Jacket Seal and Grounding Kit Included.

ABB Installation Products 162LR-B5240-SG2 200 Amp, 15kV, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter…

UPC: 075114339285


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 162LR-B5240-SG2 is a 200 Amp, 15kV loadbreak elbow connector engineered for medium-voltage cable terminations in industrial and utility applications. This connector supports cable insulation diameters from 0.635 inches to 0.905 inches, accommodating a wide range of conductor sizes including compressed stranded AWG 1/0 to 2/0 and solid AWG 2/0. The bi-metal compression lug ensures compatibility with both copper and aluminum conductors, preventing galvanic corrosion and delivering long-term reliability. Key specifications include a 15kV voltage rating and 200A current rating, making it suitable for medium-voltage systems requiring safe loadbreak operations. The integrated test point allows for voltage verification without circuit de-energization, enhancing operational safety and maintenance efficiency. The included 200ECS-G2 jacket seal and grounding kit provides a complete termination solution, ensuring watertight sealing and proper grounding for cable installations. This connector is part of ABB's 162LR series, designed for compatibility with standard 15kV loadbreak interfaces. The catalog number selection process is straightforward: determine the insulation diameter, select the appropriate material code (5 for bi-metal), and choose the compression lug code based on conductor size. The 162LR-B5240-SG2 is ideal for applications in power distribution, substations, renewable energy systems, and industrial facilities where reliable medium-voltage connections are critical. Its robust construction and comprehensive kit ensure secure, long-lasting terminations in demanding environments.
  • 200 Amp, 15kV loadbreak elbow connector for medium-voltage applications
  • Supports cable insulation diameters from 0.635 to 0.905 inches
  • Bi-metal compression lug for copper and aluminum conductor compatibility
  • Integrated test point for safe voltage verification without de-energization
  • Includes 200ECS-G2 jacket seal and grounding kit for complete termination

Specifications

Amperage Rating
200 A
Application
15kV, 200 Amp
Color
Black
Conductor Range
1/0 STR/COMPR AWG , 2/0 SOL/COMPT AWG
Connection
Push-In
Connection Type
Compression Lug
Current Rating
200 A
Environmental Conditions
All Weather Conditions
Insulation
True
Material
Bi-Metal
Material
Housing - EPDM-Rubber
Series
162LR
Size
Cable Insulation Diameter 0.635-0.905 inch
Size
7.76 inch (197.1 mm) X 9.03 inch (229.4 mm), 2.92 inch (74.2 mm) Diameter
Special Features
15kV, 200 Amp Loadbreak Elbow. Fully shielded, fully submersible molded rubber housing. 100 percent peroxide-cured construction includes insulation and conductive EPDM materials. Provision for hot stick operation. Provision for ground wire connection. Wide cable range with minimum number of sizes. Long bi-metal compression lug is standard. Non-corrosive capacitive test point
Standard
ANSI/IEEE Standard 386
Temperature Rating, Maximum
149 F
Temperature Rating, Maximum
65 C
Temperature Rating, Minimum
-40 F
Temperature Rating, Minimum
-40 C
Type
Loadbreak Elbow Connector with Test Point
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
200 Amp, 15kV, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.880 inch to 1.100 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.

168ELR88110-5240

200 Amp, 15kV, Loadbreak Repair Elbow Connector with Test Point, Cable Insulation Diameter 0.880 inch to 1.100 inch. Bi-Metal Compression Lug, Conductor Size AWG Compressed Stranded 1/0 /Solid 2/0 /mmSquared 53.49.
POWER TERMINALS TYPE 3 RENTAL

45030034

POWER TERMINALS TYPE 3 RENTAL
25/28kV, 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.890-1.220 inches (22.61-30.99mm), Copper Lug, Conductor Size 240 - 1/0 Stranded/Compressed, 2/0 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Tube of Lubricant, Crimp Chart and Installations Instructions. 9.03 x 8.20 inches, 2.86 inch diameter.

262LR-D2240

25/28kV, 200 Amp, Loadbreak Elbow Connector with Test Point, Cable Insulation Diameter 0.890-1.220 inches (22.61-30.99mm), Copper Lug, Conductor Size 240 - 1/0 Stranded/Compressed, 2/0 Solid/Compact. Kit Includes Elbow Connector Housing, Lug, Probe, Probe Wrench, Tube of Lubricant, Crimp Chart and Installations Instructions. 9.03 x 8.20 inches, 2.86 inch diameter.
25kV, 200 Amps, Loadbreak Elbow, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Conductor, Conductor Size 2/0 Stranded/Compressed, 3/0 Solid/Compact. With Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installation Instruction Sheet and Crimp Chart.

262LR-E5250

25kV, 200 Amps, Loadbreak Elbow, Cable Insulation Diameter 1.090-1.310 inches, (27.69-33.27 mm), Bi-Metal Conductor, Conductor Size 2/0 Stranded/Compressed, 3/0 Solid/Compact. With Test Point. Kit Contains Elbow Connector Housing, Compression Lug, Probe, Probe Wrench, Lubricant, Installation Instruction Sheet and Crimp Chart.
600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.370 inch to 1.630 inch. Universal Aluminum Compression Lug. Conductor Size AWG or kcmil Compressed Stranded 250, Solid 350.

755LR-M0280

600 Amp, 35kV, 600 Series Deadbreak Elbow (with Insulated Plug, Cap, Stud, Lug and Cable Adapter). Cable Insulation Diameter 1.370 inch to 1.630 inch. Universal Aluminum Compression Lug. Conductor Size AWG or kcmil Compressed Stranded 250, Solid 350.
15kV, 200 Amp Loadbreak Elbow Connector without Test Point. Cable Insulation Diameter 0.805 - 1.060 inches. Bi-Metal Conductor. Conductor Size 270 - 4/0 Stranded/Compressed or 250 kcmil Sold/Compact. S - Cold-Shrinkable Jacket Seal. Length 9.03 inches, 7.44 inch Width (without counting Probe). 2.92 Diameter.

161LR-C5270-S

15kV, 200 Amp Loadbreak Elbow Connector without Test Point. Cable Insulation Diameter 0.805 - 1.060 inches. Bi-Metal Conductor. Conductor Size 270 - 4/0 Stranded/Compressed or 250 kcmil Sold/Compact. S - Cold-Shrinkable Jacket Seal. Length 9.03 inches, 7.44 inch Width (without counting Probe). 2.92 Diameter.
600 Amp, 25kV, Stick-Op Connector Kit with Insulated Cap. Aluminum Compression Lug. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size AWG or kcmil, Compressed Stranded #2/Compacted Solid #1/mmSquared Compact 35.

K655LRTP-G0220-DRG

600 Amp, 25kV, Stick-Op Connector Kit with Insulated Cap. Aluminum Compression Lug. Cable Insulation Diameter 0.760 inch to 0.950 inch. Conductor Size AWG or kcmil, Compressed Stranded #2/Compacted Solid #1/mmSquared Compact 35.
900 Amp, 15kV Stickop Connector Kit With Test Point, No Sealing Kit. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size Compressed Stranded 500 kcmil or Compacted Solid 600 kcmil or mmSquared Compact 250/300 kcmil. Copper Conductor Only.

676LRTP-K2330-DRG

900 Amp, 15kV Stickop Connector Kit With Test Point, No Sealing Kit. Cable Insulation Diameter 1.090 inch to 1.310 inch. Conductor Size Compressed Stranded 500 kcmil or Compacted Solid 600 kcmil or mmSquared Compact 250/300 kcmil. Copper Conductor Only.

Frequently Asked Questions

What is the maximum cable insulation diameter for this connector?

The ABB 162LR-B5240-SG2 loadbreak elbow connector is designed to accommodate cable insulation diameters ranging from 0.635 inches to 0.905 inches.

What conductor sizes can be used with this elbow connector?

This connector supports compressed stranded conductors from AWG 1/0 to AWG 2/0, and solid conductors up to AWG 2/0 (53.49 mm²).

Does this connector include a grounding kit?

Yes, the 162LR-B5240-SG2 comes with the 200ECS-G2 jacket seal and grounding kit included.

What is the voltage rating of this loadbreak elbow connector?

The ABB 162LR-B5240-SG2 is rated for 15kV.

What is the purpose of the test point on this connector?

The test point on the connector allows for diagnostic testing, enabling voltage checks without de-energizing the circuit.

How to Install the 162LR Loadbreak Elbow Connector

This guide provides detailed instructions for the safe installation and preparation of the 162LR Loadbreak Elbow Connector, covering cable preparation, elbow assembly, grounding, and connection to a high-voltage bushing.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Wire brush, Crimp tool, Probe wrench, Hotstick, Suitable capacitive voltage sensing device

Supplies needed:

162LR Elbow Connector Housing, Compression Lug, Probe, Lubricant (supplied with kit), UD Cable, No. 14 AWG / 2.5mm Copper Wire, Neutral wire connector, Cleaning solution/wipes, Silicone lubricant (for test point cap)

  1. De-energize Apparatus and Inspect Components

    Before beginning installation, ensure all apparatus is de-energized. This product must be installed only by competent personnel trained in high-voltage safety practices. Inspect all components for damage, proper rating, and compatibility with mating parts. Check the probe threads by hand-threading it into the compression lug to ensure free movement for approximately four turns; replace if resistance is encountered.

  2. Prepare the Cable for Termination

    Train the UD cable to ensure adequate slack for future operation. Based on your cable type (non-jacketed, jacketed concentric neutral, jacketed with drain wires, or jacketed copper tape shield), follow the specific instructions provided in the product documentation (IS-1378, Step 1) for managing neutral wires, removing outer jackets, and cutting the cable squarely at the bushing centerline. For example, for non-jacketed concentric neutral cable, pull 24-36 inches (610-914mm) of extra cable beyond the bushing centerline and bind neutrals 7-3/4 to 8 inches (195-203mm) back from the center.

  3. Perform Detailed Cable Preparation

    Remove the cable shield and insulation 2-1/8 inches (55mm) from the cable end, ensuring a square cut without nicking the conductor. Wire brush all bare aluminum conductors thoroughly and immediately install the compression lug. Rotate the lug to spread the inhibitor and position it so the contact threaded hole aligns with the bushing bore. Crimp the lug according to the crimp chart provided with the lug, starting at the crimp line mark and rotating 180 degrees for each successive crimp. Carefully wipe off any excess inhibitor from the lug and cable. Next, remove the insulation shield 6-7/8 inches (175mm) from the lug end. Bevel the insulation end a maximum of 1/8 inch (5mm). Finally, thoroughly clean the insulation to remove all traces of dirt or excess inhibitor.

  4. Assemble the Elbow Connector Housing

    Apply the supplied lubricant to the cable insulation and inside the elbow housing. DO NOT SUBSTITUTE with other lubricants, as they may harm the product. Slide the elbow connector onto the cable using a back-and-forth twisting motion, then wipe off all excess lubricant. Align the elbow with the compression lug’s threaded hole. Thread the probe into the lug by hand, ensuring it turns freely for approximately four turns before becoming snug. Tighten the probe with the supplied wrench until the wrench bends, indicating proper torque.

  5. Ground the Elbow Connector

    Insert one end of a separate No. 14 AWG / 2.5mm copper wire or equivalent through the grounding eye on the elbow and twist it tightly, taking care not to damage the eye. Twist all neutral wires together and connect them to ground using an appropriate connector. Ensure adequate slack is provided in the wires to allow for elbow operation.

  6. Connect the Elbow to the Bushing Plug

    Before proceeding, CONFIRM THAT THE TRANSFORMER AND ELBOW ARE DE-ENERGIZED. Lubricate the receptacle portion of the elbow connector and the mating bushing with the lubricant supplied. Securely fasten a full insulated 'hotstick' type live-line tool to the loadbreak connector pulling eye. Confirm positive control of the elbow connector and, using a fast, firm, straight motion, push the elbow home into the bushing. Use sufficient force to engage the internal lock on the elbow connector and bushing interface. DO NOT OPERATE BY HAND.

  7. Perform Voltage Test (162LR Specific)

    For 162LR connectors equipped with an integral capacitance test point, you can determine if the circuit is energized. Remove the test point cap using a hotstick, peeling it off at an angle rather than pulling directly. WARNING: The voltage test point is a capacitance device and is not directly connected to the conductor. Do not use conventional voltage measuring equipment. Use a suitable sensing device specifically designed for separable connectors with capacitive test points. Contamination or incorrect equipment can give a false 'no voltage' indication; always treat the elbow as energized until confirmed otherwise by other means. After testing, clean the inside surface of the cap, lubricate with silicone lubricant, and replace it on the test point.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.