Authorized ABB Distributor (Installation Products)
ABB - Installation Products 15PCJ2H124P-F122P - 15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. With Customer Specific Modifications

ABB Installation Products 15PCJ2H124P-F122P 15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable…

UPC: 783786622375


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 15kV Power Cable Joint Style 2 (SKU: 15PCJ2H124P-F122P) is designed for reliable power cable termination and splicing. This model features a universal housing, accommodating a range of cable insulation diameters for aluminum conductors. Specifically, it supports cable insulation diameters from 0.850 inches to 1.050 inches, and also from 0.640 inches to 0.820 inches. The inclusion of separate cable adapters ensures a precise fit for varied cable constructions, simplifying installation and enhancing connection integrity. This joint is engineered for 15kV applications, providing a secure and insulated connection point for medium-voltage power distribution systems. The product is manufactured by ABB - Installation Products, a recognized leader in electrical infrastructure components. Its design prioritizes ease of use and robust performance, crucial for maintaining uninterrupted power flow in industrial and utility settings. The customer-specific modifications indicate adaptability for unique project requirements, further underscoring its versatility. This joint is an essential component for ensuring the safety and efficiency of medium-voltage electrical networks, offering a dependable solution for cable management and termination.
  • 15kV Power Cable Joint Style 2
  • Universal Housing Design
  • Separate Cable Adapters Included
  • Accommodates Aluminum Conductors
  • Supports 0.850"-1.050" & 0.640"-0.820" Insulation Diameters

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Connection
Compression
Insulation
Yes
Material
Aluminum
Material
EPDM Rubber
Number Of Conductors
2
Series
15PCJ2H
Size
16-3/8 inch long
Size
Cable Insulation Diameter 0.850 inch to 1.050 inch
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.7500 L
Package Weight (Metric)
0.7940 kg
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 1000.

15PCJ1M2400

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 1000.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #3/Solid #2.

15PCJ2G1270-F1210

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #3/Solid #2.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.

15PCJ2G1270-F1220

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.
15kv PCJ Splice No Sealing Kit. 15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

15PCJ2G1270

15kv PCJ Splice No Sealing Kit. 15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. With Customer Specific Modifications

15PCJ2H123P-F121P

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. With Customer Specific Modifications
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

15PCJ2H1240

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #4/Solid #3.

15PCJ2H1240F1200

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #4/Solid #3.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 3/0 /Solid 4/0. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.

15PCJ2G1260-F1230

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 3/0 /Solid 4/0. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.

Frequently Asked Questions

What cable insulation diameters does this joint support?

This joint supports two ranges of cable insulation diameters: 0.850 inches to 1.050 inches and 0.640 inches to 0.820 inches.

Is this joint suitable for aluminum conductors?

Yes, this ABB 15kV power cable joint is designed for use with aluminum conductors.

What is the voltage rating of this cable joint?

The product is rated for 15kV (kilovolts) power applications.

What type of housing does this ABB joint feature?

This ABB 15kV power cable joint features a universal housing.

Are cable adapters included with this joint?

Yes, this model comes with separate cable adapters for enhanced compatibility.

How to Install the 15/25/35PCJ2WXXXX-RC Cable Joint

This guide provides step-by-step instructions for the permanent, fully shielded, and submersible installation of the 15/25/35PCJ2WXXXX-RC straight joint for aluminum and/or copper conductor, wire shielded cables. Ensure all apparatus is de-energized before beginning installation to prevent serious injury.

Estimated time: 2h

Tools needed:

Stripping guide, Circular cutting tool or glass scraper, Hex wrench, Wirebrush, Crimping tool, Appropriate connector crimping tool

Supplies needed:

Joint Housing, Splice (Conductor Contact), Cable Adapters, Lubricant, Retaining Collars (2), Hose Clamp, Electrical tape, Appropriate connector (user supplied), #14 AWG copper wire or equivalent (if needed), Heat/cold shrink material (user supplied), Bonding cable(s), insulating and sealing tapes, solder, CNW's connectors (if needed, user supplied)

  1. De-energize Apparatus and Inspect Components

    Ensure all apparatus is de-energized before beginning installation. Inspect all kit components for damage, correct rating, and compatibility with the cables and mating parts. Verify both cable ends are free from moisture and contaminants.

  2. Prepare Cable Jackets

    Using a stripping guide, carefully remove the cable jacket from both cables for a distance of 11-1/4 inches (285.7mm). Fold back the shield wires and temporarily tape their ends to the jacket on Cable 1, ensuring enough length for later rejoining. Clean the surface of the insulation shield, shield wires, and jacket for 30 inches (760mm).

  3. Remove Graphite Coating and Position Housing

    Remove any graphite coatings from the cable 12 inches (30.5cm) beyond the cable jacket cut using a circular cutting tool or glass scraper; avoid sanding. Slide the joint housing onto Cable 1 for a distance of 30 inches (760mm).

  4. Prepare Cable Insulation

    Using the stripping guide, carefully remove the insulation shield and cable insulation. Exercise extreme caution to avoid cutting or nicking the insulation, as this can lead to assembly failure. Wrap two turns of tape 1 inch (25mm) from the edge of the insulation shield on both cables to serve as a marker. Clean the cable insulation, then apply lubricant to create a build-up or ramp at the edge of the insulation shield.

  5. Install Cable Adapters

    Lubricate the inside of both ends of one cable adapter. Install this cable adapter onto Cable 1 until it meets the tape marker. Repeat this process for the second cable adapter on Cable 2.

  6. Install Retaining Collars

    Select a retaining collar and partially thread the appropriate setscrews (refer to collar instructions). Position the retaining collar over the insulation, flush against the cable adapter. Using the supplied hex wrench, tighten each set screw only one or two turns at a time to keep the collar centered. Continue tightening until the setscrews are below the collar surface. Repeat for Cable 2.

  7. Prepare for Splice Installation

    Thoroughly clean the ends of the cable adapters and the exposed cable. Install a hose clamp around the adapter on the side opposite where the housing is stored to secure the adapter during final assembly. Tape over the hose clamp to create a smooth surface.

  8. Install and Crimp Splice

    Wirebrush the exposed conductors of both cables and immediately insert them into the splice. Verify the 'Check' dimension does not exceed 8-1/2 inches (215mm); if it does, redo the assembly. Crimp the splice according to its specific recommendations. Wipe off any excess inhibitor. Check the distance between cable adapters; if it exceeds 8-3/4 inches (222mm), redo the assembly.

  9. Final Housing Positioning

    Clean and lubricate the outside surface of the cable adapters. Slide the joint housing into its final position, ensuring it is centered over the cable adapters.

  10. Complete Joint Assembly and Grounding

    Remove all temporary tape. Confirm that no cable or adapter insulation is exposed after the joint is positioned. Reshape the shield wires and secure them to the ends of the joint. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye; repeat for Cable 2. If shield wires are smaller than #14 AWG, use a separate #14 AWG copper wire or equivalent. Connect the joint grounding wires and remaining shield wires using an appropriate user-supplied connector.

  11. Reconstruct Cable Jacket

    Reconstruct the cable jacket (where applicable) over both cables and the joint housing using user-supplied heat or cold shrink material.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.