Authorized ABB Distributor (Installation Products)
ABB - Installation Products 15PCJ2G1280 - 15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 250.

ABB Installation Products 15PCJ2G1280 15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable…

UPC: 075114238885


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

This ABB 15kV Power Cable Joint, SKU 15PCJ2G1280, is designed for reliable electrical connections in medium-voltage applications. It features a Style 2 joint configuration with a universal housing, ensuring broad compatibility. The product includes separate cable adapters, facilitating precise fitting for specific cable constructions. Key specifications include suitability for cable insulation diameters ranging from 0.760 inches to 0.950 inches. This joint is engineered for aluminum conductors, specifically accommodating stranded conductors sized at 250 AWG. The robust design ensures secure and insulated connections, critical for maintaining system integrity and preventing electrical faults in power distribution networks. ABB's Installation Products division provides this component, adhering to established industry standards for medium-voltage cable accessories. The universal housing simplifies inventory management by allowing a single housing to accommodate a range of cable sizes within the specified diameter range. The separate adapters offer enhanced flexibility during installation, allowing for optimal sealing and mechanical stress relief tailored to the conductor size and insulation type.
  • 15kV Power Cable Joint, Style 2
  • Universal Housing for broad compatibility
  • Includes Separate Cable Adapters
  • Cable Insulation Diameter Range: 0.760" - 0.950"
  • Designed for 250 AWG Stranded Aluminum Conductor

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
250 kcmil
Connection
Compression
Insulation
Yes
Material
Aluminum
Material
EPDM Rubber
Number Of Conductors
2
Series
15PCJ2G
Size
16-3/8 inch long
Size
0.760 inch to 0.950 inch
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
1.0000 L
Package Weight (Metric)
0.4540 kg
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 250.

15PCJ1-J2280

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Copper Conductor. Conductor Size AWG Stranded 250.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. With Customer Specific Modifications

15PCJ2H124P-F122P

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. With Customer Specific Modifications
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #3/Solid #2.

15PCJ2G1270-F1210

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #3/Solid #2.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.

15PCJ2G1270-F1220

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #2/Solid #1.
15kv PCJ Splice No Sealing Kit. 15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

15PCJ2G1270

15kv PCJ Splice No Sealing Kit. 15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. With Customer Specific Modifications

15PCJ2H123P-F121P

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. With Customer Specific Modifications
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

15PCJ2H1240

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #4/Solid #3.

15PCJ2H1240F1200

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.850 inch to 1.050 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #4/Solid #3.

Frequently Asked Questions

What voltage classes are available for PCJ joints?

Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

What are the two styles of PCJ power cable joints?

Style 1 is for straight splicing of two similar cables. Style 2 includes separate cable adapters for transition splicing between different cable sizes.

What are the two styles of PCJ power cable joints?

Style 1 is for straight splicing of two similar cables. Style 2 includes separate cable adapters for transition splicing between different cable sizes.

What voltage classes are available for PCJ joints?

Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

What voltage classes are available for PCJ joints?

Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

What are the two styles of PCJ power cable joints?

Style 1 is for straight splicing of two similar cables. Style 2 includes separate cable adapters for transition splicing between different cable sizes.

What voltage classes are available for PCJ joints?

Elastimold PCJ power cable joints are available in 15 kV, 25 kV, and 35 kV classes.

What are the two styles of PCJ power cable joints?

Style 1 is for straight splicing of two similar cables. Style 2 includes separate cable adapters for transition splicing between different cable sizes.

What conductor materials are compatible with PCJ joints?

These joints can be used with copper or aluminum conductors. They support a wide range of sizes up to 1250 kcmil.

Where can PCJ power cable joints be installed?

They can be installed in direct-burial, underground vault, and overhead applications. They provide a permanent, fully shielded, fully submersible splice.

How to Install a 15PCJ2G1280 Straight Joint

This guide provides step-by-step instructions for the permanent, fully shielded, and submersible installation of a 15PCJ2G1280 straight joint. It covers preparation, wiring, and final assembly for aluminum and/or copper conductor, wire shielded cables.

Estimated time: 1h 30m

Tools needed:

Cable stripping tool, Wire strippers, Wirebrush, Hex wrench, Crimping tool, Cutting tool (for graphite removal)

Supplies needed:

Joint Housing, Splice (Conductor Contact), Cable Adapters, Lubricant, Retaining Collars, Hose Clamp, Electrical tape, Appropriate connector (for grounding wires), #14 AWG copper wire or equivalent, Heat/cold shrink kit (for jacket reconstruction)

  1. Initial Safety and Inspection

    Before starting, ensure all apparatus is de-energized. Inspect all components for damage and compatibility. This product must be installed by competent personnel trained in high voltage safety practices. Failure to follow instructions can result in serious injury or product damage.

  2. Prepare Cables and Install Housing

    Carefully remove 11-1/4" (285.7mm) of cable jacket from both cables. Fold back shield wires on Cable 1 and tape their ends. Clean the insulation shield, shield wires, and jacket for 30" (760mm). Slide the joint housing onto Cable 1 for 30" (760mm).

  3. Prepare Cable Insulation

    Using the stripping guide, carefully remove the insulation shield and cable insulation from both cables. DO NOT CUT OR NICK THE INSULATION, as this can cause failure. Wrap two turns of tape 1" (25mm) from the insulation shield edge on both cables as a marker. Clean and lubricate the cable insulation to create a build-up at the insulation shield edge.

  4. Install Cable Adapters

    Lubricate the inside of both ends of one cable adapter. Install this adapter onto Cable 1 until it meets the tape marker. Repeat this process for the second cable adapter on Cable 2.

  5. Install Retaining Collars

    Select a retaining collar and partially thread its setscrews. Position the collar over the insulation, flush against the cable adapter on Cable 1. Using the supplied hex wrench, tighten each setscrew one or two turns at a time to keep the collar centered, continuing until setscrews are below the collar surface. Repeat for Cable 2.

  6. Splice Conductors

    Thoroughly clean the ends of the cable adapters and the cable. Install a hose clamp around the adapter on the opposite side of the splice from the stored housing, then tape over it to form a smooth surface. Wirebrush the exposed conductors of both cables and immediately insert them into the splice. Crimp the splice according to its recommendations. Wipe off excess inhibitor and verify the distance between cable adapters does not exceed 8-3/4" (222mm). Clean and lubricate the outside surface of the cable adapters.

  7. Complete Joint Assembly and Grounding

    Slide the housing into its final position, centering it over the cable adapters. Remove all tape, ensuring no cable or adapter insulation is exposed. Reshape and secure shield wires to the joint ends. Insert one shield wire from Cable 1 (if #14 AWG or larger) through the joint grounding eye, and repeat for Cable 2 (use separate #14 AWG copper wire if shield wires are smaller). Connect all grounding wires and remaining shield wires using an appropriate connector. Reconstruct the cable jacket over both cables and the joint housing using a heat/cold shrink kit.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.