Authorized ABB Distributor (Installation Products)
ABB - Installation Products 15PCJ1G2220 - 15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.760 inch to 0.950 inch. Copper Conductor. Conductor Size AWG Stranded #2/Solid #1.

ABB Installation Products 15PCJ1G2220 15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter…

UPC: 783786662081


Documents & Media
BrochureInstallation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Minimum Qty: 30

Multiplier: 30

*Contact for lower quantities*

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The ABB 15PCJ1G2220 is a 15kV Power Cable Joint, Style 1, designed for reliable medium-voltage power cable termination. This fully shielded, fully submersible splice is rated per IEEE Standard 404 and is suitable for direct burial or vault installations. The single-piece housing simplifies installation and ensures electrical and water seal integrity at the cable entrance. It accommodates cable insulation diameters from 0.760 inches to 0.950 inches, with a broader range of 0.640” to 2.120” supported by the Elastimold® 15PCJ1 series. This joint is engineered for copper conductors, supporting stranded AWG #2 and solid AWG #1 conductor sizes. The molded conductive shield provides a virtually indestructible ground shield for deadfront construction, and a grounding eye is included for connecting a ground wire. The cable entrance engages the insulation shielding, eliminating the need for taping. Key ratings include 110kV BIL, 35kV AC withstand, and 13kV AC corona extinction. Continuous current rating matches the cable rating, with a short-time current rating up to 35kA. Connectors meet ANSI C119.4 Class A and Class 3 ratings. The pin and socket interlock can withstand pulls of up to 500 lbs. This product is part of ABB's Installation Products catalog, known for quality in electrical infrastructure.
  • 15kV Voltage Class, IEEE Standard 404 Rated
  • Fully Shielded, Fully Submersible Single-Piece Housing
  • Accommodates Cable Insulation Diameters: 0.760" - 0.950"
  • Designed for Copper Conductors (Stranded AWG #2 / Solid AWG #1)
  • Deadfront Construction with Molded Conductive Shield and Grounding Eye

Specifications

Application
For Direct Burial, Vault, Submersible and Other Severe Service Applications
Color
Black
Conductor Range
#4 STR AWG , #3 SOL AWG #2 STR AWG , #1 SOL AWG
Connection
Compression
Insulation
Yes
Material
Copper
Material
EPDM Rubber
Number Of Conductors
2
Series
Style 1
Size
14-3/8 inch long
Size
0.760 inch to 0.950 inch
Size
0.760 inch to 0.950 inch (insulation diameter)
Special Features
Power Cable Joints utilize permanently crimped connectors. PCJ housings are fully insulated, shielded and sealed for direct-burial, vault, submersible and other servere service applications. Units have been designed and tested per IEEE Standard 404 to ensure system matched performance and ratings equal to the cable to which the splice will be installed. Power Cable Joints are available in two styles. Style 1 uses a single-piece housing that is sized to accommodate a specific range of cable - ideally suited to straight splicing of the same or similar cable. Style 2 designs incorporate a universal housing with separate cable adapters to allow transition splices of different types and sizes of cable
Standard
IEEE Standard 404
Type
Power Cable Joint
Voltage Rating
15 kV
Package Dimensions (L x W x H)
0.01 IN x 0.01 IN x 0.01 IN
Package Dimensions (L x W x H)
0.0254 cm x 0.0254 cm x 0.0254 cm
Package Weight (Imperial)
0.8000 L
Package Weight (Metric)
0.3630 kg
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 1000.

15PCJ1M2400

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Copper Conductor. Conductor Size AWG Solid 1000.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.900 inch to 2.120 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000.

35PCJ1Q1410

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.900 inch to 2.120 inch. Aluminum Conductor. Conductor Size AWG Stranded 1000.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

25PCJ1L1270

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.180 inch to 1.465 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.

35PCJ1J1240

35kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 1/0 /Solid 2/0.
15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Conductor. Conductor Size AWG Solid 350.

15PCJ1H2290

15kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 0.850 inch to 1.050 inch. Copper Conductor. Conductor Size AWG Solid 350.
25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.

25PCJ1M1330

25kV Power Cable Joint Style 1 with Single Piece Housing, Cable Insulation Diameter 1.370 inch to 1.630 inch. Aluminum Conductor. Conductor Size AWG Stranded 500.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.

15PCJ2J1270

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.980 inch to 1.180 inch. Aluminum Conductor. Conductor Size AWG Stranded 4/0 /Solid 250.
15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.

15PCJ2G1230-F1230

15kV Power Cable Joint Style 2 with Universal Housing and Separate Cable Adapters. Cable Insulation Diameter 0.760 inch to 0.950 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0. Cable Insulation Diameter 0.640 inch to 0.820 inch. Aluminum Conductor. Conductor Size AWG Stranded #1/Solid 1/0.

Frequently Asked Questions

What type of conductor does this joint support?

This ABB cable joint is compatible with copper conductors, specifically AWG #2 stranded or AWG #1 solid.

What is the voltage rating of this ABB power cable joint?

The ABB 15kV Power Cable Joint Style 1 has a voltage rating of 15kV.

What is the housing style of this ABB cable joint?

This ABB cable joint features a single-piece housing design.

What is the insulation diameter range for this ABB cable joint?

The ABB 15kV Power Cable Joint Style 1 is designed for cable insulation diameters ranging from 0.760 inches to 0.950 inches.

How to Install the 15PCJ1G2220 Single Core Joint

This guide provides detailed instructions for the permanent, fully screened, submersible installation of the 15PCJ1G2220 Single Core Joint for extruded solid dielectric cables, ensuring proper cable preparation, connector installation, and screen restoration.

Estimated time: 1h 30m

Tools needed:

Wire strippers, Utility knife, Wire brush, Crimping tool, Heat gun, Soldering iron (optional, if not using constant force springs), Clean cloths

Supplies needed:

15PCJ1G2220 Joint Housing, PVC tape (multiple colors), Copper or aluminum compression connector, Cleaning solvent, Lubricant (supplied with joint), Flat copper braid, Constant force springs (optional, if not soldering), Mastic tape, Heat shrink

  1. Perform Initial Safety Checks and Prepare Cables

    DANGER: De-energize all apparatus. Installation by competent personnel only. Inspect parts for damage and compatibility. Train cables, square cut leaving 5mm, and store heat shrink on one cable.

  2. Remove Cable Jacket and Metallic Shield

    Remove both cable jackets to specified dimensions (e.g., 405mm for Size A). Carefully remove metallic tape screen (e.g., 125mm for Size A) and secure ends with PVC tape. Ensure PVC tape is on copper tape only, not overlapping the non-metallic screen.

  3. Remove Non-Metallic Screen and Prepare Insulation

    WARNING: Do not nick insulation or conductor. Remove non-metallic screen from both cables to specified point (e.g., 45mm for Size D). Bevel Cable 1 edge. Cut insulation to conductor to 'E' (e.g., 150mm) from both ends, DO NOT remove. Install PVC tape marker on Cable 2 to 'B' (e.g., 155mm) for splice location.

  4. Temporarily Store the Joint Housing

    Apply one layer (half lapped) of PVC tape over metallic screen, starting at jacket and extending 10mm beyond screen end. Install a different color PVC tape marker on Cable 1 to 'B' (e.g., 155mm). Lubricate both cable entrances of housing. Clean and lubricate insulation, non-metallic screen, and PVC taped metallic screen on Cable 1. Store housing onto Cable 1 up to the jacket. WARNING: Cover sharp edges of metallic screen with PVC tape to prevent damage. DO NOT store on exposed metallic tape shield.

  5. Remove Cable Insulation and Install Connector

    Remove cable insulation from both cables to 'E' (e.g., 45mm). DO NOT cut or nick. Wire brush exposed conductors. Immediately insert conductors into splice, ensuring full seating. DO NOT crimp yet. Check insulation distance; if exceeding 'Before' dimension (e.g., 108mm), review. Crimp splice per chart. Remove burrs and metal chips. Wipe excess inhibitor. Check insulation distance again; if exceeding 'After' dimension (e.g., 102mm), review.

  6. Clean and Lubricate Core Surfaces

    WARNING: Remove all contaminants. Clean conductor, connector, and Cable 2 insulation surfaces with solvent and clean cloth, wiping towards screen end. Lubricate cable insulation surfaces with supplied lubricant, wiping toward screen end to build up lubricant at non-metallic screen edge.

  7. Install Joint Housing and Restore Screen

    Slide joint housing over crimp connector into final position. Measure distance 'X' between housing and PVC tape markers; 'X' must be equal on both sides. Remove PVC tape from Step C to expose 25mm of copper tape. Wrap flat copper braid around each joint housing, overlapping metallic tape screen by 20mm on each side. Attach braid ends to metallic tape screen by soldering or using a constant force spring.

  8. Restore Outer Jacket

    Lightly sand outer jacket surface of both cables for 130mm. Heat both sanded areas for approximately 15 seconds; DO NOT BURN. Wrap two layers of mastic tape at the jacket edge on both cables. Position heat shrink from Cable 1 over the center of the assembly and shrink it, starting at the center and working toward the ends.

Frequently Asked Questions about ABB - Installation Products

How are Thomas and Betts products typically installed?

Thomas and Betts products are installed using a variety of methods tailored to specific applications, including the use of flexible cords and cable fittings, non-metallic cable glands, and armored cable fittings. Proper selection of fittings is crucial to match the cable type and installation environment, ensuring durability and preventing physical damage. Tools such as the Blackburn® Comfort Crimp® and HEX-FLEX® systems enhance installation efficiency and reliability, reducing labor time and ensuring secure connections.

What accessories are available for Thomas and Betts products?

Thomas and Betts offers a comprehensive range of accessories for their products, including various cord and cable fittings, non-metallic cable glands, service entrance cable fittings, and armored cable fittings. Their accessories are designed to enhance installation efficiency and ensure compatibility with different cable types and environmental conditions, providing reliable connections for a wide array of applications.

What environmental ratings do Thomas and Betts products have?

Thomas and Betts products feature robust environmental ratings, including NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications, as well as IEC 60529 IP66 protection. These ratings ensure that their products are designed to withstand harsh industrial environments, with capabilities to resist dust, water, and corrosion, and operate effectively in a wide temperature range.

What communication protocols do Thomas and Betts products support?

Thomas and Betts products support a wide range of industrial communication protocols, including Ethernet, DeviceNet, PROFIBUS, Modbus, CANopen, and others. This extensive compatibility ensures seamless integration and reliable communication across various industrial automation systems, catering to diverse application needs.

What are the key features of Thomas and Betts products?

Thomas and Betts products are known for their innovative designs, high performance, and compliance with industry standards such as the National Electrical Code and Underwriters' Laboratories. They offer a comprehensive range of rugged and reliable electrical fittings, including liquidtight and dust-tight connections, which enhance installation efficiency and reduce overall project costs. Their products are engineered for durability in harsh environments, ensuring long-term reliability and lower installed costs.

What are the main product lines offered by Thomas and Betts?

Thomas and Betts offers a comprehensive range of product lines including electrical connectors, cable management systems, grounding and bonding solutions, and industrial automation components. Their products are designed for durability and reliability in demanding industrial environments, ensuring optimal performance and safety across various applications.

What technical support does Thomas and Betts offer?

Thomas and Betts offers comprehensive technical support, including access to field application engineers for onsite training and installation assistance. Their technical support staff is available to address inquiries related to product specifications and installation practices, ensuring optimal performance and safety of electrical systems. Additionally, they provide a variety of training programs to enhance the knowledge and skills of users in the field.

What industries and applications are Thomas and Betts products used for?

Thomas and Betts products are utilized across various industries including electrical construction, industrial automation, telecommunications, and utilities. Their extensive range of cord and cable fittings, electrical boxes, and metal framing systems are designed for applications that require durability and reliability in harsh environments, ensuring optimal performance in both permanent and temporary installations.

What certifications and standards do Thomas and Betts products comply with?

Thomas and Betts products comply with critical international certifications including UL (Underwriters Laboratories), CSA (Canadian Standards Association), and CE (European Community). Our products are designed to meet rigorous industrial standards such as NEMA enclosure ratings and IEC 60529 IP ratings, ensuring safety and reliability across various industrial applications.

What are the main product lines offered by Ocal?

Ocal offers a comprehensive range of corrosion-resistant conduit systems, including PVC-coated conduit and fittings, conduit bodies, hazardous location fittings, and strut accessories. Their products are designed to provide superior corrosion protection, featuring a hot-dipped galvanizing process and UL listed Type 4X PVC-coated conduit bodies, ensuring durability in the most demanding environments.