Showing 313-324 of 66,285 results

Littelfuse · E7800 Series
E7800.0650
Motorized Potentiometer 24VDC, 0.8-6 rpm. The E7800 Motorized Potentiometer is typically used as an interface between increase/decrease relay contacts (or push buttons) and a device requiring control by an external potentiometer (e.g. the speed trim of an electronic governor). All three wires of the potentiometer are directly accessible on external connection terminals, thus providing the best possible flexibility for almost any application. A special version of the E7800 with DC voltage output is also available. The DC output voltage follows the position of the potentiometer. The design of the E7800 ensures that the potentiometer will “remember” its position although supply is lost
Contact for Pricing

The SE-CS10 series current transformers (CTs) are key components of the Littelfuse protection relay product line. Littelfuse SE-134C and SE-135 Ground-Fault Ground-Check Monitors are designed specifically for use with the SE-CS10 CTs. A Littelfuse SE-330 Neutral-Grounding-Resistor Monitor and a Littelfuse SE-701 Ground-Fault Monitor can also be equipped with the SE-CS10 series to achieve the desired ground-fault-trip settings. Littelfuse motor- and feeder-protection relays can also make use of the SE-CS10 series either to measure phase current or ground-fault current.
Contact for Pricing

SE-325T is a neutral-grounding resistor monitor with a supply voltage of 120 ac and a ground-fault trip level of 0.5–4.0 A.
Contact for Pricing

SE-325SN is a neutral-grounding resistor monitor with a supply voltage of 120 ac and a ground-fault trip level of 0.5–4.0 A.
Contact for Pricing

Contact for Pricing

TIMING RELAY RTW17-A02U100SD90 WEG specifications: Function On-delay; Output contacts 2 NO/NC; Timing 10-100s; Control voltage 208-480V 50/60Hz; A1-A2 terminals voltage 208-480 V 50/60Hz
Contact for Pricing

MONITORING RELAY RMW17-SS01D39 WEG specifications: Type Monitoring; Function Three-phase under/overvoltage; Output contacts 1 NO/NC
Contact for Pricing

Socomec
47247603
The Socomec product with SKU 47247603 is designed for industrial applications requiring robust power management and distribution. Engineered for reliability and efficiency, this solution ensures optimal performance in demanding environments. Ideal for industrial facilities, data centers, and manufacturing plants, it provides seamless power distribution and protection. With advanced features and durable construction, it meets the highest standards for industrial power systems. Trust Socomec for dependable power solutions that enhance operational efficiency and safety.
Contact for Pricing

Socomec
47112727
The Socomec industrial power distribution equipment (SKU: 47112727) is designed to provide reliable and efficient electrical power distribution for industrial applications. Engineered with precision and durability, this product ensures optimal performance in demanding environments. Its robust construction and advanced features make it ideal for use in manufacturing plants, data centers, and other critical infrastructure. With a focus on safety and efficiency, this equipment helps maintain uninterrupted power supply, reducing downtime and enhancing operational productivity. Trust Socomec for high-quality power distribution solutions that meet the rigorous demands of modern industrial operations.
Contact for Pricing

Contact for Pricing

The DCSA Series is a loop-powered, linear output current transducer that provides an output that is directly proportional to the RMS AC current passing through the LCSC10T12 sensor. The DCSA provides either an analog current or voltage: 4 - 20 mA, 1 to 5VDC, or 2 to 10VDC. Each unit is factory calibrated for monitoring (with the LCSC10T12 connected) in one of four ranges; 0 - 5, 0 - 10, 0 - 20, or 0 - 50A. Zero and span adjustments allow field calibration if needed. The DCSA mounts on both DIN 1 and DIN 3 rails.
Contact for Pricing

The 777-575-P2 three-phase current and voltage monitor provides motor protection with input voltage from 500–600 V ac and motor full load ampere range as follows: 2–20 A (looped conductors required); 20–90 A (direct); 90–800 A (external CTs required).
Contact for Pricing