Authorized nVent Distributor
nVent VJ1614WWHITE - VJ Flat Opaque Cover Type 4X, 17.32x15.32x6.6, Wht, FRP, W

nVent VJ1614WWHITE VJ Flat Opaque Cover Type 4X, 17.32x15.32x6.6, Wht, FRP, W

UPC: 635394030069


Documents & Media
Installation InstructionsSpecification SheetManufacturer Product Website

Contact for Pricing

Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.

Overview

The nVent VJ Flat Opaque Cover, SKU VJ1614WWHITE, is engineered for demanding industrial applications where superior protection against corrosive environments is paramount. Manufactured by nVent, a trusted leader in electrical enclosure solutions, this Type 4X rated enclosure is constructed from robust Fiberglass Reinforced Polyester (FRP) in a clean white finish, ensuring exceptional durability and resistance to harsh chemicals, moisture, and UV exposure. Its substantial dimensions of 17.32 inches in height, 15.32 inches in width, and 6.6 inches in depth provide ample space for housing sensitive electrical junction boxes and control equipment. VJ enclosures, including the VJ1614WWHITE, are specifically designed for use in highly corrosive environments, offering a reliable barrier to protect vital equipment and personnel. The opaque cover design ensures that internal components are shielded from direct sunlight and potential damage, while the Type 4X rating signifies its suitability for both indoor and outdoor installations, capable of withstanding water, dust, and even powerful water jets. This makes it an ideal choice for industries such as chemical processing, wastewater treatment, marine, and food and beverage manufacturing, where aggressive atmospheric conditions are commonplace. Key benefits of the nVent VJ Flat Opaque Cover include: * **Superior Corrosion Resistance:** FRP material is inherently resistant to a wide range of corrosive agents, extending the lifespan of housed equipment. * **Robust Environmental Protection:** Type 4X rating provides excellent defense against water ingress, dust, and other environmental contaminants. * **Enhanced Equipment Safety:** Protects electrical components from damage, ensuring operational continuity and preventing costly downtime. * **Operator Safety:** Safeguards personnel from accidental contact with live electrical parts. * **Durable Construction:** Built to withstand the rigors of industrial settings, offering long-term reliability. Installation of the VJ1614WWHITE is straightforward, allowing for efficient integration into existing electrical infrastructure. The opaque FRP construction not only provides physical protection but also contributes to thermal management by reflecting sunlight. Professionals rely on nVent enclosures for their consistent quality, innovative design, and adherence to stringent industry standards. This specific model, VJ1614WWHITE, embodies these qualities, offering a dependable solution for critical electrical protection needs in challenging industrial landscapes. Its origin in the USA further underscores a commitment to quality manufacturing and accessibility for North American markets.
  • Available sized from 6x6 (152x152mm) to 30x30 (762x762mm).
  • All VJ enclosures were designed to meet the Joint Industrial Council (JIC) standards in the United States.
  • Enclosures are maintenance free and corrosion resistant.
  • Made from hot compression molded halogen free, self extinguishing fiberglass reinforced polyester (FRP).
  • Polyurethane foam-in-place gasket.
  • Molded mounting flanges and cover corner ribs increase enclosure strength.
  • Enclosures can be modified to customer specifications.
  • Enclosures can be modified to customer specifications.

Specifications

Application
Corrosive Environments; Controls and Drives
Application
Controls and Drives;Corrosive Environments
Color
White
Color Code
Not defined
Depth
169 mm
Depth
6.67 in
Finish
Smooth Matte
Height
17.32 in
Height
440 mm
Material
Fiberglass
Material Quality
Fiberglass
Product Family
VJ
Protection Rating
NEMA Type 3
Style
Stainless steel with corner screws
Type
Fiberglass and Thermoplastic Wall Mounted Industrial Enclosures
Weight
10.6 lb
Width
15.32 in
Width
389 mm
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco

36297702

Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

Frequently Asked Questions

What material is the VJ1614WWHITE enclosure made from?

The enclosure is made from hot compression molded, halogen-free, self-extinguishing fiberglass reinforced polyester (FRP).

What are the dimensions of the VJ1614WWHITE enclosure?

The VJ1614WWHITE enclosure has a height of 17.32 inches, a width of 15.32 inches, and a depth of 6.67 inches.

What is the color of the VJ1614WWHITE enclosure?

The VJ1614WWHITE enclosure is white with a smooth matte finish.

What industry standards does the VJ enclosure meet?

VJ enclosures meet UL 508A Listed; Type 3, 3R, 4, 4X, 12, 13 and cUL Listed per CSA C22.2 No 94 standards.

What NEMA/EEMAC types do VJ enclosures meet?

VJ enclosures meet NEMA/EEMAC Type 3, 3R, 4, 4X, 12, and 13.

What is the purpose of VJ enclosures?

VJ enclosures are designed for use as electrical junction boxes in corrosive environments, protecting equipment and operators.

What is the IP rating of the VJ enclosure?

The VJ enclosure meets IEC 60529, IP66 standards.

Is the VJ enclosure maintenance-free?

Yes, VJ enclosures are designed to be maintenance-free and corrosion-resistant.

What type of gasket is used on the VJ enclosure?

The enclosure features a polyurethane foam-in-place gasket.

Can VJ enclosures be modified to customer specifications?

Yes, VJ enclosures can be modified to meet customer specifications.

How to Install the VJ1614WWHITE Enclosure

Guide for mounting and preparing the VJ1614WWHITE enclosure for use. Ensure proper installation for optimal performance and safety.

Estimated time: 30m

Tools needed:

Screwdriver, Drill (if mounting holes are not pre-drilled), Level

Supplies needed:

Mounting screws, Wire connectors, Air vents (if not included)

  1. Select Mounting Location

    Choose a suitable location for the VJ1614WWHITE enclosure. Consider environmental factors and accessibility for maintenance. Ensure the mounting surface is stable and can support the weight of the enclosure and its contents. Refer to the datasheet for specific environmental ratings and limitations.

  2. Prepare the Enclosure

    If required, install air vents for proper circulation. Two air vents should be installed, ideally in the upper and lower parts of the enclosure, to prevent condensation. Refer to the specific part number for air vent installation instructions and required hardware.

  3. Mount the Enclosure

    Securely mount the VJ1614WWHITE enclosure to the chosen surface using appropriate mounting screws. Ensure the enclosure is level and firmly attached. For enclosures with molded mounting flanges, align these with the mounting surface and fasten securely. Verify that the enclosure meets the required NEMA/EEMAC or IP ratings for the intended environment.

  4. Wiring and Connections

    Open the enclosure and proceed with internal wiring and connections as per your application requirements. Ensure all electrical connections are made in accordance with local codes and standards. For specific wiring details or internal component compatibility, consult the product's datasheet.

  5. Final Inspection and Closure

    After completing all internal installations and wiring, perform a final inspection to ensure all components are securely fastened and all connections are correct. Close and secure the enclosure cover, ensuring the gasket provides a proper seal. Verify that all latches or screws are tightened appropriately.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.