Overview

The nVent T1Flo Vented Enclosure (SKU: T1F80LP) provides essential thermal management for industrial control systems. Featuring a thermostatically controlled, forced-air ventilation system, it actively removes excess heat to maintain optimal operating temperatures for sensitive electronics. Constructed from durable 14-gauge steel with an ANSI 61 gray polyester powder coat finish, this Type 1 enclosure is built for demanding environments. It is ideal for HVAC and general industrial applications housing components like Variable Frequency Drives (VFDs), inverters, and PLCs. The enclosure includes a factory-installed 115 VAC fan and a washable expanded metal filter for efficient cooling and easy maintenance. Its design features a lift-off hinged door with a slotted quarter-turn latch for convenient access, collar studs for optional panel mounting, and rear mounting holes. The T1Flo enclosure meets UL 508A Listed, cUL Listed, NEMA/EEMAC Type 1, and IEC 60529, IP20 standards. Dimensions are 28.00x24.00x12.75 inches.
  • Lift-off Hinged Door
  • Active cooling ventilation system with factory installed, thermostatically controlled fan (115 VAC) and filter
  • Terminal block power connection for fan
  • Washable expanded metal filter
  • Slotted quarter-turn latch
  • Collar studs for mounting optional panel
  • Grounding provision on door and body
  • Mounting holes on back of enclosure
  • Accepts optional mounting foot kit
  • Door gasket

Specifications

Application
Controls and Drives;Power Distribution
Application
Power Distribution; Controls and Drives
Color
Gray
Color
Grey
Color Code
ANSI 61
Connection Type
Screw Terminal (for fan power)
Depth
324
Depth
12.75 in
Depth
324 mm
Fan Quantity
1
Fan Size
4 in
Finish
Powder Coated
Height
28 IN
Height
711 mm
IP Rating
IP20
IP Rating
IP30
Material
Mild Steel
Material
Steel
Modification Services
Yes
Mounting Type
Panel mounting (collar studs), Rear mounting holes, Optional mounting foot kits
NEMA Rating
1
NEMA Rating
1 Indoor, electrical protection
NEMA Rating
Type 1
Panel Gauge
12
Panel Size
21.00 x 21.00 in
Panel Size
533 x 533 mm
Perforated Panel
A24P24PP
Product Family
T1Flo
Protection Rating
NEMA Type 1
Series
T1Flo
Size
28.00x24.00x12.75 in
Size
28.00x24.00x12.75 inches
Size
28.00x24.00x12.75
Solid Panel
A24P24
Suggested Horsepower
3 HP
Suggested Horsepower
3-3 HP
System CFM
80 ft³/min
Thickness
51.40mm (2.024")
Thickness
1.9 mm
Thickness
14 ga
Type
Mild Steel Wall Mounted Industrial Enclosures
Type
Wall-Mounted / Pad-Mounted Enclosures
Type Number
Type 1
Voltage Rating
115 VAC
Weight
72 lb
Width
610 mm
Width
24 IN
Package Dimensions (L x W x H)
28.75 IN x 25 IN x 13.75 IN
Package Dimensions (L x W x H)
73.025 cm x 63.5 cm x 34.925 cm
Package Weight (Imperial)
72.000 L
Package Weight (Metric)
32.659 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco

36297702

Locking using CASTELL K key operated lock (not supplied) Fuserbloc Sirco
External operation handle 0-1 type S01 Red Nema 4,4x

140E2911

External operation handle 0-1 type S01 Red Nema 4,4x
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

How to Install Conduit Entry into T1F80LP Enclosures

Instructions for installing conduit entry into nVent Hoffman rainproof enclosures.

Estimated time: 30m

Tools needed:

Drill, Punch, Screwdriver

Supplies needed:

U.L. listed rain tight or liquid tight conduit hubs, Conduit, Locknuts, Locking bushing

  1. Determine Conduit Entry Location

    Decide whether the conduit entry will be above or below live parts. Refer to the document for specific requirements for each scenario.

  2. Install Conduit Hubs (If Applicable)

    If conduit entry is above live parts, use only U.L. listed rain tight or liquid tight conduit hubs. Install the hubs and conduit according to the hub manufacturer's instructions.

  3. Prepare Enclosure for Conduit

    If conduit entry is below live parts, punch or drill the correct size hole for the conduit to be used, or use the appropriate knockout if provided. Refer to the table for correct hole sizes based on conduit size.

  4. Secure the Conduit

    Secure the conduit using locknuts inside and out, or by using a locking bushing on the inside and a locknut on the outside. Ensure a tight and secure fit.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.