nVent RHJ1210HWLG - Raised Cover Hinged with Screws Type 4X, 11.68x9.69x6.16, Fiberglass
nVent

RHJ1210HWLG

UPC: 783510158576


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The **nVent RHJ1210HWLG Raised Cover Hinged Enclosure** delivers superior protection for sensitive electrical and electronic components in demanding industrial environments. Engineered with a **Type 4X fiberglass construction**, this enclosure is designed to withstand harsh conditions, including exposure to water, dust, and corrosive atmospheres, making it ideal for outdoor and indoor applications where durability and reliability are critical. The **raised, overlapping-cover design** ensures a secure seal, preventing moisture ingress and maintaining internal integrity even in extreme weather or high-humidity settings. This design also provides **additional internal space**, allowing for easier component mounting and better cable management—essential for maximizing efficiency in control panels, junction boxes, and automation systems. **Key Features & Benefits** - **Type 4X Rating**: Certified for protection against water, dust, and corrosion, ensuring long-term performance in outdoor and industrial environments. This rating is essential for applications in chemical plants, water treatment facilities, and marine settings where exposure to the elements is constant. - **Fiberglass Construction**: Lightweight yet rugged, fiberglass enclosures offer excellent dielectric strength, chemical resistance, and UV stability. Unlike metal enclosures, they do not corrode, rust, or conduct electricity, reducing the risk of short circuits and electrical hazards. - **Hinged Cover with Screws**: The **removable and hinged cover** provides easy access for installation, maintenance, and inspections without compromising the enclosure’s protective seal. The screw-secured design ensures the cover remains firmly in place, even in high-vibration environments like manufacturing floors or transportation hubs. - **Optimized Internal Dimensions**: With internal dimensions of **11.68 x 9.69 x 6.16 inches**, this enclosure offers ample space for mounting circuit breakers, relays, PLCs, and other critical components. The raised cover design allows for additional clearance, accommodating bulkier components or thicker cable bundles. - **Versatile Mounting Options**: Designed for both wall-mounted and surface-mounted applications, the RHJ1210HWLG can be installed in control rooms, substations, or remote locations where space and accessibility are key considerations. **Industry Applications** The **nVent RHJ1210HWLG** is a versatile solution for a wide range of industries, including: - **Oil & Gas**: Protecting instrumentation and control systems in refineries, pipelines, and offshore platforms where explosion-proof and corrosion-resistant enclosures are mandatory. - **Water & Wastewater Treatment**: Safeguarding electrical components in pumping stations, filtration systems, and treatment plants exposed to moisture and chemicals. - **Manufacturing & Automation**: Housing PLCs, HMIs, and motor controllers in facilities with high vibration, dust, or temperature fluctuations. - **Renewable Energy**: Enclosing inverters, batteries, and monitoring systems in solar farms and wind turbines, where weather resistance and durability are paramount. - **Transportation & Infrastructure**: Securing traffic control systems, lighting controls, and communication equipment in tunnels, bridges, and rail stations. **Why Choose nVent for Industrial Enclosures?** nVent is a globally recognized leader in thermal management and electrical protection solutions, trusted by engineers and facility managers for over a century. Their enclosures are engineered to meet stringent industry standards, including **NEMA, UL, and IEC certifications**, ensuring compliance with safety and performance requirements. The **RHJ1210HWLG** exemplifies nVent’s commitment to innovation, offering a combination of **durability, flexibility, and ease of installation** that reduces downtime and maintenance costs. Whether you’re retrofitting an existing system or designing a new installation, this enclosure provides the reliability and protection your components need to operate flawlessly. **Installation & Maintenance Considerations** Proper installation is critical to maximizing the lifespan and performance of the RHJ1210HWLG. Professionals recommend: - **Sealing Gaskets**: Ensure the gasket is properly seated to maintain the Type 4X rating. Inspect gaskets regularly for wear or damage and replace as needed. - **Ventilation**: While the enclosure is sealed, consider adding ventilation or cooling accessories if housing heat-generating components to prevent overheating. - **Mounting Surface**: Use appropriate mounting hardware and ensure the surface is clean, flat, and capable of supporting the enclosure’s weight. For outdoor applications, consider additional weatherproofing measures. - **Cable Entry**: Use cable glands or conduit fittings rated for the environment to maintain the enclosure’s ingress protection (IP) rating. For maintenance, the hinged cover design allows for quick access to internal components without tools, simplifying inspections and repairs. Regularly check for signs of corrosion, gasket degradation, or loose screws to ensure continued protection. **Conclusion** The **nVent RHJ1210HWLG Raised Cover Hinged Enclosure** is a high-performance, corrosion-resistant solution designed to protect critical electrical and electronic components in the most challenging environments. With its **Type 4X rating, fiberglass construction, and hinged cover**, it offers unmatched durability, security, and flexibility for industrial applications. Whether you’re upgrading a control panel, installing new automation equipment, or safeguarding instrumentation in a harsh facility, this enclosure delivers the reliability and performance you need. Trust nVent’s expertise to keep your systems running smoothly, even in the toughest conditions.
  • Type 4X rated for water, dust, and corrosion resistance
  • Fiberglass construction for lightweight durability and chemical resistance
  • Hinged cover with screws for easy access and secure sealing
  • 11.68x9.69x6.16in internal dimensions for flexible component mounting
  • Ideal for oil & gas, water treatment, manufacturing, and renewable energy
  • Enclosures protect equipment and operators from indirect electrical contact

Specifications

Aluminum Panel
A12P10AL
Application
Corrosive Environments; Controls and Drives
Color
Light Gray
Color Code
RAL 7035
Depth
6.16
Depth
156
Door Fasteners
Hinged, 2 screws
Finish
Smooth Matte
Height
11.68
Height
297
IP Rating
IP66
Material
Fiberglass
Modification Services
Yes
NEMA Rating
4X Watertight, corrosion-resistant
Panel Size
10.75 x 8.88 in
Product Family
HJ
Protection Rating
NEMA Type 12
Size
13.30x11.29x7.10 in
Steel Panel
A12P10
Style
Hinged Cover
Thickness
0.12 in
Type
Fiberglass and Thermoplastic Wall Mounted Industrial Enclosures
Weight
6.6 lb
Width
9.69
Width
246
Package Dimensions (L x W x H)
13.8 IN x 11.9 IN x 8 IN
Package Dimensions (L x W x H)
35.052 cm x 30.226 cm x 20.32 cm
Package Weight (Imperial)
6.600 L
Package Weight (Metric)
2.994 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the RHJ1210HWLG Controller

This guide provides step-by-step instructions for the installation and initial setup of the RHJ1210HWLG controller, including wiring and configuration.

Estimated time: 45m

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors

  1. Mount the controller

    Secure the RHJ1210HWLG controller to the DIN rail using the integrated clips. Ensure the controller is level and firmly attached.

  2. Connect the wiring

    Use the appropriate terminal connectors to connect the power supply and input/output wires to the controller. Ensure all connections are tight and secure.

  3. Verify the connections

    Use a multimeter to check the voltage at the power supply terminals. Ensure the voltage matches the specifications outlined in the controller's manual.

  4. Configure the controller settings

    Access the controller's configuration interface and input the necessary parameters such as operational modes and communication settings.

  5. Calibrate the controller

    Follow the calibration procedure in the manual to ensure the controller operates accurately. This may involve adjusting settings based on the connected sensors.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.