nVent RHJ1008HWLG - Raised Cover Hinged with Screws Type 4X, 9.70x7.71x5.91, Fiberglass
nVent

RHJ1008HWLG

UPC: 783510158569


Documents & Media
Installation Instructions

Contact for Pricing

Overview

The nVent HOFFMAN RHJ1008HWLG is a Type 4X fiberglass enclosure designed for robust protection of electrical and electronic components in harsh industrial environments. Measuring 9.70 inches in height, 7.71 inches in width, and 5.91 inches in depth, this enclosure is constructed from durable, compression-molded fiberglass, offering excellent corrosion resistance. The raised, hinged cover is secured with stainless steel screws and features Type 304 stainless steel piano hinges for reliable access and sealing. This design ensures an enhanced seal against moisture and dust, meeting IP66 and NEMA Type 4X standards. Integral mounting brackets are included for straightforward wall mounting. The RHJ1008HWLG is UL 508A Listed and cUL Listed, compliant with NEMA Types 3, 3R, 4, 4X, 12, and 13, making it suitable for a wide range of industrial applications including chemical processing, food and beverage, and wastewater treatment facilities. Its light gray finish (RAL 7035) provides a professional appearance. Optional panels and accessories are available for customization.
  • Durable compression-molded fiberglass construction
  • NEMA Type 4X and IP66 rated for superior protection
  • Raised, hinged cover with stainless steel screws and piano hinges
  • Integral mounting brackets for easy installation
  • UL 508A Listed and cUL Listed for industrial compliance
  • Enclosures protect equipment and operators from indirect electrical contact

Specifications

Aluminum Panel
A10P8AL
Application
Corrosive Environments; Controls and Drives
Color
Light Gray
Color Code
RAL 7035
Depth
5.91 in
Door Fasteners
Hinged, 2 screws
Finish
Smooth Matte
Height
9.7
Height
246
IP Rating
IP66
Material
Fiberglass
Modification Services
Yes
NEMA Rating
4X Watertight, corrosion-resistant
Panel Size
8.75 x 6.88 in
Product Family
HJ
Protection Rating
NEMA Type 12
Size
11.31x9.31x6.93 in
Steel Panel
A10P8
Style
Hinged Cover
Thickness
0.12 in
Type
Fiberglass and Thermoplastic Wall Mounted Industrial Enclosures
Weight
5.1 lb
Width
7.71
Width
196
Package Dimensions (L x W x H)
11.8 IN x 9.8 IN x 7.9 IN
Package Dimensions (L x W x H)
29.972 cm x 24.892 cm x 20.066 cm
Package Weight (Imperial)
5.100 L
Package Weight (Metric)
2.313 kg
Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum

14A0705

Panel 6.9 x 4.9 - Fits Encl. 8 x 6 - Alum
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.

BX4

Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black

LH38

Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
EP-RJG-M20-BL-A

1SNG618003R0000

EP-RJG-M20-BL-A
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey

LN43DA

1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey

LT20D-NEW

1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
Escutcheon black type B for Sircover 125-630A

44095015

Escutcheon black type B for Sircover 125-630A
Escutcheon black type B for Sircover 125-630A IP65

44095016

Escutcheon black type B for Sircover 125-630A IP65
12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12

FF20A115UE1

12,80" x 12,80" filter fan - 115Vac - 285.3 cfm - RAL 7035 - Type 12
5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

FF12D24NN53

5,90" x 5,90" filter fan - 24Vdc - 20.6 cfm - RAL 9005 - Type 3R - IP55

How to Install the RHJ1008HWLG Controller

This guide provides step-by-step instructions for installing and configuring the RHJ1008HWLG Controller, including wiring and initial setup.

Estimated time: 1h

Tools needed:

Screwdriver, Wire strippers, Multimeter

Supplies needed:

Mounting screws, Terminal connectors, Grounding bushing

  1. Prepare the enclosure

    Cut holes in the enclosure at the desired locations for conduit entry using a Greenlee Cutter. Ensure the holes are clean and free of debris.

  2. Connect the conduit

    Secure the conduit connector (hub) onto the conduit and insert it into the prepared hole. Use the connector locknut to fasten it securely.

  3. Install grounding

    Attach the grounding bushing over the connector locknut and connect the grounding conductor to the equipment grounding terminal, following the National Electrical Code.

  4. Mount the controller

    Secure the RHJ1008HWLG Controller to the DIN rail using the integrated clips. Ensure it is level and firmly attached.

  5. Wire the controller

    Connect the power and signal wires to the appropriate terminals on the controller. Use a multimeter to verify correct voltage levels.

  6. Configure the controller

    Power on the controller and follow the manufacturer's instructions to complete the initial configuration settings.

  7. Calibrate the system

    Perform any necessary calibration procedures as outlined in the user manual to ensure optimal performance.

Frequently Asked Questions about nVent

What industries and applications are nVent products used for?

nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.

What environmental ratings do nVent products have?

nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.

What accessories are available for nVent products?

nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.

What certifications and standards do nVent products comply with?

nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.

What is nVent's warranty policy?

nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.

What technical support does nVent offer?

nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.