Overview
- Durable compression-molded fiberglass construction
- NEMA Type 4X and IP66 rated for superior protection
- Raised, hinged cover with stainless steel screws and piano hinges
- Integral mounting brackets for easy installation
- UL 508A Listed and cUL Listed for industrial compliance
- Enclosures protect equipment and operators from indirect electrical contact
Specifications
Aluminum Panel | A10P8AL |
Application | Corrosive Environments; Controls and Drives |
Color | Light Gray |
Color Code | RAL 7035 |
Depth | 5.91 in |
Door Fasteners | Hinged, 2 screws |
Finish | Smooth Matte |
Height | 9.7 |
Height | 246 |
IP Rating | IP66 |
Material | Fiberglass |
Modification Services | Yes |
NEMA Rating | 4X Watertight, corrosion-resistant |
Panel Size | 8.75 x 6.88 in |
Product Family | HJ |
Protection Rating | NEMA Type 12 |
Size | 11.31x9.31x6.93 in |
Steel Panel | A10P8 |
Style | Hinged Cover |
Thickness | 0.12 in |
Type | Fiberglass and Thermoplastic Wall Mounted Industrial Enclosures |
Weight | 5.1 lb |
Width | 7.71 |
Width | 196 |
Package Dimensions (L x W x H) | 11.8 IN x 9.8 IN x 7.9 IN |
Package Dimensions (L x W x H) | 29.972 cm x 24.892 cm x 20.066 cm |
Package Weight (Imperial) | 5.100 L |
Package Weight (Metric) | 2.313 kg |

BX4
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
LH38
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
LN43DA
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
LT20D-NEW
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, GreyHow to Install the RHJ1008HWLG Controller
This guide provides step-by-step instructions for installing and configuring the RHJ1008HWLG Controller, including wiring and initial setup.
Estimated time: 1h
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors, Grounding bushing
- Prepare the enclosure
Cut holes in the enclosure at the desired locations for conduit entry using a Greenlee Cutter. Ensure the holes are clean and free of debris.
- Connect the conduit
Secure the conduit connector (hub) onto the conduit and insert it into the prepared hole. Use the connector locknut to fasten it securely.
- Install grounding
Attach the grounding bushing over the connector locknut and connect the grounding conductor to the equipment grounding terminal, following the National Electrical Code.
- Mount the controller
Secure the RHJ1008HWLG Controller to the DIN rail using the integrated clips. Ensure it is level and firmly attached.
- Wire the controller
Connect the power and signal wires to the appropriate terminals on the controller. Use a multimeter to verify correct voltage levels.
- Configure the controller
Power on the controller and follow the manufacturer's instructions to complete the initial configuration settings.
- Calibrate the system
Perform any necessary calibration procedures as outlined in the user manual to ensure optimal performance.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.