Contact for Pricing
Minimum Qty: 4
Multiplier: 4
*Contact for lower quantities*
Overview
- 2.00" x 22.00" x 120.00" straight section for efficient cable routing
- Lightweight steel wire mesh with durable light gray powder coating
- Open-mesh design promotes airflow and reduces heat buildup
- Modular system compatible with tees, crosses, elbows, and dropouts
- Snap-together installation with pre-punched mounting holes for fast setup
Specifications
Application | Networking, Storage and Data Center |
Cable Quantity, Cat 6 @75% Fill | 600 |
Color | Unpainted |
Fill Rate, Cat 6 diam. 0.19 in | 600 |
Fill Rate, Cat 6A diam. 0.23 in | 554 |
Load | 73 lb/ft |
Load Per 6 ft Span | 73 lb/ft |
Modification Services | No |
Nominal Width | 22 in |
Product Family | QuickTray Pro |
Splice Quantity | 5 |
Splice Quantity, Per Joint | 5 |
Thickness | 0.2 in |
Type | Cable Pathway |
Weight | 27 lb |
Weight Per Section | 27 lb |
Package Dimensions (L x W x H) | 120 IN x 22 IN x 2 IN |
Package Dimensions (L x W x H) | 304.8 cm x 55.88 cm x 5.08 cm |
Package Weight (Imperial) | 27.000 L |
Package Weight (Metric) | 12.247 kg |
How to Cut, Form, and Connect QUICK TRAY PRO™ Cable Tray Sections
This guide provides instructions for safely cutting, bending, and joining QUICK TRAY PRO™ cable tray sections to create custom cable management pathways for various installations.
Estimated time: 1h 30m
Tools needed:
Hoffman Side Action Bolt Cutter (QTPBC)
Supplies needed:
QUICK TRAY PRO™ Cable Tray sections, Splice Kits (QTPBNWK or QTPBNWKBLK), Splice Washers (QTPSSW3 or QTPSSW3BLK), Universal Splice Bars (QTPUS10 or QTPUS10BLK, as needed), T-Connection or 90o Splice Bars (QTP90TKIT or QTP90TKITBLK, as needed)
- Plan Your Cuts and Bends
Before cutting, carefully review the required cutting patterns for your desired configuration, such as 90-degree bends, elbows, tees, or width reductions. Identify all wires that must be removed according to the specific tray size and bend type. Always use the Hoffman side action bolt cutter for precision cuts that minimize sharp edges and help protect against corrosion.
- Cut Cable Tray Wires
Starting with the top side wire, position the cutting jaws on the cradle wire and make the cut at an angle away from the new end. Repeat this process for all remaining side wires. Turn the tray over and cut the bottom wires from the underside, ensuring the cutting jaws rest on the cradle wire and cut at an angle away from the new end. Make one clean cut for each wire to avoid grinding or touch-up.
- Create a 90-Degree Bend
At the desired bend location, cut all side wires for the specific width of your cable tray as indicated in the cutting patterns. Turn the tray on the uncut side and smoothly bend the tray upwards until the inside edges closest to the uncut side meet. Secure the bend using QTPBNWK/QTPBNWKBLK Splice Kits and QTPSSW3/QTPSSW3BLK Splice Washers at the indicated locations for your tray width.
- Join Cable Tray Sections
To connect two straight sections or to form an elbow or tee, align the wires of the two tray sections at the desired angle. Fasten the trays together using QTPBNWK/QTPBNWKBLK Splice Kits and QTPSSW3/QTPSSW3BLK Splice Washers. For adjustable elbows or tees, use one splice kit and one splice washer centered over two tray bottom wires. For other connections, use two splice kits and washers per joint as indicated for the tray size. For 90-degree tees, incorporate a QTP90TKIT/QTP90TKITBLK T-Connection Splice Bar.
- Install Cable Tray Supports
Install straight section supports at typical 6-foot (1.5m) centers. Ensure supports are placed within 24 inches (610mm) of any splice on straight sections. The span between supports must not exceed the length of the tray. Provide additional supports around bends and wherever the cable tray level changes to maintain stability and proper load distribution.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.