nVent PSB3030A PolySafe Flat Cover with Bonded Window Type 4X, 29.53x29.53x12.60, Lt Gray, Fiberglass, A
UPC: 635394549042
Contact for Pricing
Call +1 (262) 252-1600 (toll-free 877-268-3700) or email [email protected] for pricing and availability.
Overview
- Enclosures are maintenance free and corrosion resistant
- Bases and covers are hot compression molded from halogen free, self extinguishing fiberglass reinforced polyester (FRP) that can withstand continuous temperatures from -58°F to 302°F (-50°C to 150°C) and momentary exposure to 392°F (200°C)
- Windows are made from 1/4” transparent Lexan
- Can be coupled in height, width and depth for wall mounting and freestanding units
- Standard 3 or 5 point latching mechanism (dependant on size
- All enclosures can be easily modified to customer specifications
- Gaskets are made from continuously poured polyurethane foam
Specifications
Application | Corrosive Environments; Controls and Drives |
Application | Controls and Drives;Corrosive Environments |
Color | Light Gray |
Color | Lt Gray |
Color | Gray |
Color | Grey |
Color Code | RAL 7035 |
Depth | 12.6 in |
Depth | 320 mm |
Finish | Smooth Matte |
Height | 750 mm |
Height | 29.53 in |
Height | 750 |
Material | Fiberglass |
Material Quality | Fiberglass |
Mounting Type | Integral Mounting Brackets |
Nema Rating | Type 4X |
Product Family | Polysafe |
Protection Rating | NEMA Type 3 |
Series | PolySafe |
Size | 29.53x29.53x12.60 |
Size | 29.53x29.53x12.60 inches |
Style | Stainless steel pinned hinges and 3 or 5 point latching mechanism with full turn standard handle |
Type | Fiberglass and Thermoplastic Wall Mounted Industrial Enclosures |
Weight | 43.8 lb |
Width | 750 mm |
Width | 29.53 in |

BX4
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
LH38
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, Black
LN43DA
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
LT20D-NEW
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, GreyFrequently Asked Questions
What are the dimensions of the PSB3030A enclosure?
The PSB3030A enclosure has a height of 29.53 inches, a width of 29.53 inches, and a depth of 12.6 inches.
What materials is the PSB3030A enclosure made from?
The enclosure bases and covers are made from halogen-free, self-extinguishing fiberglass reinforced polyester (FRP). The window is made from 1/4 inch transparent Lexan.
What is the operating temperature range for this enclosure?
The enclosure can withstand continuous temperatures from -58°F to 302°F (-50°C to 150°C).
What industry standards does the PSB3030A enclosure meet?
It is UL Listed for Types 3, 3R, 3S, 4, 4X, 12, 13 and CSA for Types 3, 3R, 3S, 12, 13.
Is the PSB3030A enclosure maintenance-free?
Yes, the enclosures are maintenance-free and corrosion-resistant.
What type of latching mechanism does the enclosure have?
The enclosure features a standard 3 or 5 point latching mechanism with a full turn standard handle.
Can the enclosure be modified?
Yes, all enclosures can be easily modified to customer specifications.
What is the color of the PSB3030A enclosure?
The enclosure is light gray with a color code of RAL 7035.
What is the weight of the PSB3030A enclosure?
The weight of the PSB3030A enclosure is 43.8lb.
What are the typical uses for Polysafe enclosures?
Polysafe enclosures protect electrical and electronic controls and can be used as junction boxes, terminal wiring boxes, instrument housings, and electrical control housings.
How to Install the Polysafe Enclosure
This guide provides step-by-step instructions for installing and configuring the Polysafe enclosure for electrical and electronic controls.
Estimated time: 45m
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Terminal connectors
- Mount the enclosure
Secure the enclosure to the desired surface using the provided mounting screws. Ensure it is level and firmly attached.
- Connect the wiring
Use wire strippers to prepare the wires and connect them to the terminal connectors inside the enclosure. Ensure all connections are tight and secure.
- Verify electrical connections
Use a multimeter to check the voltage and continuity of the connections. Ensure that all readings are within the specified range.
- Seal the enclosure
Close the enclosure doors and ensure that the gaskets are properly seated to maintain the enclosure's IP65 rating.
- Calibrate the system
Follow the manufacturer's guidelines to calibrate any installed equipment within the enclosure, ensuring optimal performance.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.