
Contact for Pricing
Overview
- Mounts to the bottom of the enclosure
- Constructed from 16-gauge steel for robust support
- Finished with RAL 7035 textured light-gray polyester powder paint
- EMC compliant paint application over plated surfaces
- Provides a stable and secure foundation for industrial enclosures
Specifications
Application | Power Distribution; Controls and Drives |
Color | Light Gray |
Color Code | RAL 7035 |
Finish | Powder Coated |
Fits Frame | 600 x 400 mm |
IP Rating | IP55 |
Material | Mild Steel |
Material | Steel |
Modification Services | Yes |
Mounting Type | Floor Mount |
Product Family | ProLine |
Series | nVent Solid Base |
Size | fits 600x400mm |
Size | 600x400mm |
Thickness | 1.52 mm |
Thickness | 16 ga |
Type | External Mounting for ProLine Industrial Enclosures |
Weight | 8.9 lb |
Package Dimensions (L x W x H) | 24 IN x 20.25 IN x 3 IN |
Package Dimensions (L x W x H) | 60.96 cm x 51.435 cm x 7.62 cm |
Package Weight (Imperial) | 8.900 L |
Package Weight (Metric) | 4.037 kg |

BX4
Sealable and transparent protective covers BX4 and non-removable BX4-CA to protect the devices against accidental contact.
LT20D-NEW
1/2 Inch, 90 Degree, Two-Piece Liquidtight Non-Metallic Fitting, UL E32447, Temperatures up to 107 Degrees C, Nitril Rubber O-Ring, PVC, Grey
LN43DA
1/2 Inch, Straight, One-Piece Liquidtight Non-Metallic Fitting, CSA, UL E32447, Temperatures up to 60 Degrees C, PVC, Grey
LH38
Cord Grip with NPT Threads, Locknut Included, NPT Thread Size 3/8 Inch, Cable Range 0.181 Inch/4.6mm to 0.312 Inch/7.9mm, Hole Clearance 0.670 Inch/17.0mm, Thread Length 0.53 Inch/13.5mm, IP68 Rating, Nylon, BlackHow to Install the PB064 Controller
This guide provides step-by-step instructions for installing and configuring the PB064 Controller, ensuring proper wiring and initial setup.
Estimated time: 1h
Tools needed:
Screwdriver, Wire strippers, Multimeter
Supplies needed:
Mounting screws, Wire connectors
- Mount the controller
Secure the PB064 Controller to the designated mounting surface using the provided mounting screws. Ensure it is level and securely fastened.
- Connect the wiring
Use wire strippers to prepare the wires and connect them to the appropriate terminals on the PB064 Controller. Ensure all connections are tight and secure to prevent any electrical issues.
- Power on the controller
Turn on the power supply to the PB064 Controller. Use a multimeter to verify that the voltage levels are within the specified range.
- Configure the settings
Access the configuration menu on the PB064 Controller and input the necessary parameters as per your application requirements. Save the settings before exiting.
- Calibrate the controller
Follow the calibration procedure outlined in the user manual to ensure the PB064 Controller operates accurately. Adjust settings as needed based on the calibration results.
Frequently Asked Questions about nVent
What industries and applications are nVent products used for?
nVent products are engineered for critical infrastructure and industrial applications across multiple demanding sectors. Key markets include Construction, Data Centers, Defense, Healthcare, Mining, Oil & Gas Refineries, Power Plants, Rail/Transit, Renewable Energy, Security, Ship Building, Steel Mills, Telecom, and Utilities. Their solutions are designed to withstand extreme environmental conditions, with temperature ranges from -55°C to 105°C and specialized features like UV resistance, oil resistance, and flame resistance.
What environmental ratings do nVent products have?
nVent enclosures feature comprehensive environmental ratings, including UL 508A, CSA, and NEMA Type 1, 2, 3, 4, 4X, 12, and 13 certifications. They are rated IEC 60529 IP66, providing robust protection against dust, water, and corrosion in both indoor and outdoor environments. These products operate effectively in temperatures ranging from -40°F to 266°F, with enhanced UV inhibitors for outdoor weathering and oil-resistant gaskets for superior sealing.
What accessories are available for nVent products?
nVent offers a comprehensive range of accessories across multiple product lines, including EMC accessories like bonding cable clamps and strain reliefs, inline accessories such as lock inserts and mounting brackets, CONCEPT accessories including panel conversion kits and rack-mount angles, and seismic accessories for specialized mounting requirements. Key accessory categories include grounding kits, DIN rail mounting solutions, panel supports, handles, and various mounting hardware compatible with different enclosure types.
What certifications and standards do nVent products comply with?
nVent products meet critical international certifications including UL (United States), CSA (Canada), CE (European Community), and EAC (Russia). Our products are designed to comply with rigorous industrial standards such as NEMA enclosure ratings, IEC 60529 IP ratings, and international safety standards across multiple industrial markets including oil & gas, power, manufacturing, and infrastructure.
What is nVent's warranty policy?
nVent offers a standard 18-month warranty from invoicing date for most automation products, covering defects in workmanship and materials. The warranty requires proper transportation, handling, storage, and installation within specified environmental conditions. Warranty coverage includes repair or replacement at nVent's discretion, with certain conditions such as authorized service repairs and operation within designed capacity limits.
What technical support does nVent offer?
nVent offers comprehensive technical support through multiple global contact centers across North America, South America, Europe, Middle East, India, and Asia. Customers can reach technical experts by phone at regional numbers, with the North American headquarters in Minneapolis, MN providing primary support at +1.763.421.2240. Additionally, nVent provides online support resources through their website, including CAD drawing downloads and an 'Ask The Expert' feature to assist with product technical inquiries.

















